Bayesian Saliency Model for Focal Liver Lesion Enhancement and Detection

被引:1
|
作者
Han, Xian-Hua [1 ,2 ]
Wang, Jian [1 ,2 ]
Konno, Yuu [1 ,2 ]
Chen, Yen-Wei [1 ,2 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Koutou Ku, 2-3-26 Aomi, Tokyo 1350064, Japan
[2] Ritsumeikan Univ, 1-1-1 Nojihigashi, Kusatsu 5248577, Japan
关键词
D O I
10.1007/978-3-319-54526-4_3
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Focal liver lesion enhancement and detection has an essential role for the computer-aided diagnosis and characterization of lesion regions in CT volume data. This paper proposes a novel focal lesion enhancement strategy by extracting a lesion saliency map, which represents the deviation degree of the uncommon or lesion tissue from the common tissues (liver and vessel) in CT volumes. The saliency map can be constructed by exploring the existing probability of lesion for any voxel. However, due to the large diversity of liver lesions, it is difficult to construct an universal model for all types of lesions. Therefore, this study proposes to construct probability models of the common tissues, which have comparably small variability even for different samples and is relatively easy to obtain the prototype regions even from the understudying CT volume. In order to robustly and flexibly characterize the common tissues, we explore a Bayesian framework by combining a general model, which is constructed oriented to all CT samples, and an adaptive model, which is constructed specific to the under-studying CT sample, for calculating the existing probability of the common tissues (liver or vessel). Then, the saliency map (the existing probability) of focal lesion can be deduced from that of liver or vessel. The advantages of our proposed strategy mainly include three aspects: (1) it only needs to prepare the prototypes of common tissue such as liver or vessel region, which are easily obtained in any CT liver volume; (2) it proposes to combine the general and adaptive model as Bayesian framework for more robust and flexible characterization of the common tissue; (3) dispensable to remove the other different structure such as vessel in liver volume as a pre-processing step. Experiments validate that the proposed Bayesian-based saliency model for focal liver lesion enhancement can perform much better than the conventional approaches such as EM, EM/MPM based lesion detection and segmentation methods.
引用
收藏
页码:32 / 45
页数:14
相关论文
共 50 条
  • [31] Focal Liver Lesion Detection in Ultrasound Image Using Deep Feature Fusions and Super Resolution
    Mostafiz, Rafid
    Rahman, Mohammad Motiur
    Islam, A. K. M. Kamrul
    Belkasim, Saeid
    MACHINE LEARNING AND KNOWLEDGE EXTRACTION, 2020, 2 (03): : 172 - 191
  • [32] Importance of Distending Stomach With Fluid for Ultrasound Detection of Focal Lesion in the Elongated Left Lobe of the Liver
    Wu, Size
    Liu, Guangqing
    Cui, Xiaojing
    Liang, Xian
    Chen, Kailiang
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (12) : 2553 - 2558
  • [33] Saliency detection via Boolean and foreground in a dynamic Bayesian framework
    Qi, Wei
    Han, Jing
    Zhang, Yi
    Bai, Lianfa
    VISUAL COMPUTER, 2017, 33 (02): : 209 - 220
  • [34] RGB-D Saliency Detection under Bayesian Framework
    Wang, Song-Tao
    Zhou, Zhen
    Qu, Han-Bing
    Li, Bin
    2016 23RD INTERNATIONAL CONFERENCE ON PATTERN RECOGNITION (ICPR), 2016, : 1881 - 1886
  • [35] Bayesian salient object detection based on saliency driven clustering
    Zhou, Lei
    Fu, Keren
    Li, Yijun
    Qiao, Yu
    He, XiangJian
    Yang, Jie
    SIGNAL PROCESSING-IMAGE COMMUNICATION, 2014, 29 (03) : 434 - 447
  • [36] Saliency detection via Boolean and foreground in a dynamic Bayesian framework
    Wei Qi
    Jing Han
    Yi Zhang
    Lianfa Bai
    The Visual Computer, 2017, 33 : 209 - 220
  • [37] Improved Saliency Detection based on Bayesian Framework for Object Proposal
    Li, Jie
    Xu, Wei
    Yuan, Xia
    Zhao, Chunxia
    2016 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO), 2016, : 2093 - 2098
  • [38] DIAGNOSTIC CONTRAST ENHANCED ULTRASOUND IN FOCAL LIVER LESION
    Salama, Fady
    Thakral, Nimish
    Konjeti, Venkata Rajesh
    Dawkins, Adrian
    Gedaly, Roberto
    Khurana, Aman
    GASTROENTEROLOGY, 2022, 162 (07) : S1165 - S1165
  • [39] The incidental focal liver lesion: Photon, proton, or needle?
    Ros, PR
    Davis, GL
    HEPATOLOGY, 1998, 27 (05) : 1183 - 1190
  • [40] Laparoscopic radiofrequency of a liver focal lesion of colorrectal origin
    Perez-Robledo, J. P.
    Prieto-Nieto, M. I.
    Olveira, A.
    Marti de Gracia, M.
    Erdozain, J. C.
    Carrion, G.
    Segura, J. M.
    Rodriguez-Montes, J. A.
    Garcia-Sancho Martin, L.
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2008, 100 (04) : 250 - 252