Design and Analysis of Novel Focused Hyperthermia Devices

被引:11
|
作者
Ho, S. L. [1 ]
Niu, Shuangxia [1 ]
Fu, W. N. [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Elect Engn, Kowloon, Hong Kong, Peoples R China
关键词
Field-free region; finite element method; focused hyperthermia; magnetic fluid hyperthermia;
D O I
10.1109/TMAG.2012.2198622
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Magnetic fluid hyperthermia (MFH) is a promising cancer therapy by virtue of its good depth penetration. As the injected magnetic fluids of MFH are inevitably distributed in the tumor as well as in normal tissues nearby, it is difficult to accurately heat and ablate the targeted tumor without damaging the surrounding healthy tissues. Based on the observation that magnetic nanoparticles are only heated by alternating fields and not by static dc fields, it is possible to exploit such findings in MFH therapy to provide an efficient cure for cancer patients. To avoid unnecessary heating of healthy tissues, a novel system is proposed to set up a dc magnetic field around the tumor target. At the same time, the system creates a field-free region (FFR) with negligible static magnetic field in the target area. The target area can then be fully heated by an alternating field whereas the nearby tissues are not heated. In this paper, a novel ac and dc magnetic field combined MFH system, targeting the treatment area, is presented to produce an accurately focused magnetic field to abate the tumor cells. The proposed method is validated using finite element analysis.
引用
收藏
页码:3254 / 3257
页数:4
相关论文
共 50 条
  • [41] NONLINEAR EFFECTS WITH FOCUSED ULTRASOUND IN TISSUES - AN APPLICATION FOR HYPERTHERMIA
    SWINDELL, W
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 828 - 829
  • [42] NONLINEAR ABSORPTION DURING SCANNED FOCUSED ULTRASOUND HYPERTHERMIA
    HYNYNEN, K
    ROEMER, RB
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 107 - 107
  • [43] A LOCAL HYPERTHERMIA SYSTEM USING FOCUSED ULTRASOUND TRANSDUCERS
    DICKINSON, RJ
    HAND, JW
    STRAHLENTHERAPIE, 1983, 159 (06) : 370 - 370
  • [44] Optimal Focused Electromagnetic Hyperthermia Treatment of Breast Cancer
    Iero, Domenica A. M.
    Crocco, Lorenzo
    Isernia, Tommaso
    Korkmaz, Erdal
    2016 10TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2016,
  • [45] Optimization of pulsed focused ultrasound exposures for hyperthermia applications
    Wang, Shutao
    Frenkel, Victor
    Zderic, Vesna
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (01): : 599 - 609
  • [46] OPTIMIZATION OF TEMPERATURE DISTRIBUTIONS IN SCANNED, FOCUSED ULTRASOUND HYPERTHERMIA
    LIN, WL
    ROEMER, RB
    MOROS, EG
    HYNYNEN, K
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1992, 8 (01) : 61 - 78
  • [47] FOCUSED ULTRASOUND FOR THE CLINICAL-APPLICATION OF LOCAL HYPERTHERMIA
    DICKINSON, RJ
    HAND, JW
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (02): : 167 - 167
  • [48] Development of focused microwave hyperthermia of pediatric brain cancer
    Trefna, H. Dobsicek
    Kok, H. P.
    Takook, P.
    Gellermann, J.
    Lannering, B.
    Blomgren, K.
    Crezee, H.
    Persson, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S685 - S686
  • [49] ANALYSIS OF MEDICAL DEVICES DESIGN REQUIREMENTS
    Chen, Mingbin
    Chen, Zhenyu
    Kong, Lan
    Zeng, Yong
    JOURNAL OF INTEGRATED DESIGN & PROCESS SCIENCE, 2005, 9 (04) : 61 - 70
  • [50] Focused ion beam applications for design and product analysis
    Lange, J.A.
    Czapski, S.