Calibration of the Sandia Array Performance Model Using Indoor Measurements

被引:0
|
作者
Hansen, Clifford W. [1 ]
Riley, Daniel M. [1 ]
Jaramillo, Manuel [2 ]
机构
[1] Sandia Natl Labs, POB 5800, Albuquerque, NM 87185 USA
[2] CFV Solar Test Lab Inc, Albuquerque, NM 87106 USA
关键词
Modeling; Parameter extraction; Performance analysis; Photovoltaic systems; Solar power generation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Sandia Array Performance Model (SAPM) describes the DC output of a PV module under a range of irradiance and temperature conditions. Coefficients for SAPM are normally obtained through a sequence of on-sun tests, which can be expensive and time-consuming. We report progress towards developing test methods and analysis procedures to obtain coefficients for SAPM from indoor testing. We compared module output predictions from SAPM with coefficients extracted from indoor test results, to measured on-sun module output, and found biases in the predicted performance. We hypothesize that these biases result from the uniform cell temperatures during indoor testing, whereas measured cell temperatures vary by up to 10 degrees C among cells during on-sun conditions. However, we also hypothesize other explanations for the observed biases.
引用
收藏
页码:3067 / 3072
页数:6
相关论文
共 50 条
  • [31] On the interest of using full field measurements in ductile damage model calibration
    Roux, E.
    Bouchard, P-O
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2015, 72 : 50 - 62
  • [32] TDR Calibration for Soil Moisture Measurements Using a Spectroscopic Dielectric Model
    Mironov, V. L.
    Kosolapova, L. G.
    Muzalevskiy, K. V.
    PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 311 - 314
  • [33] Calibration of satellite measurements of river discharge using a global hydrology model
    Brakenridge, G. Robert
    Cohen, Sagy
    Kettner, Albert J.
    De Groeve, Tom
    Nghiem, Son V.
    Syvitski, James P. M.
    Fekete, Balazs M.
    JOURNAL OF HYDROLOGY, 2012, 475 : 123 - 136
  • [34] Performance of MIMO spatial multiplexing algorithms using indoor channel measurements and models
    Spencer, QH
    Svantesson, T
    Swindlehurst, AL
    WIRELESS COMMUNICATIONS & MOBILE COMPUTING, 2004, 4 (07): : 739 - 754
  • [35] Calibration of an indoor radio propagation prediction model at 2.4 GHz by measurements of the IEEE 802.11b preamble
    Jemai, J
    Piesiewicz, R
    Kürner, T
    VTC2005-SPRING: 2005 IEEE 61ST VEHICULAR TECHNOLOGY CONFERENCE, VOLS 1-5, PROCEEDINGS, 2005, : 111 - 115
  • [36] RECEIVING CALIBRATION AND BEAM PATTERN MEASUREMENTS OF A LARGE SONAR ARRAY WITH A PARAMETRIC TRANSMITTING ARRAY
    TRUCHARD, JJ
    WILLETTE, JG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (01): : 384 - &
  • [37] ARRAY CALIBRATION USING ARRAY RESPONSE INTERPOLATION AND PARAMETRIC MODELING
    Yang, Bin
    McKelvey, Tomas
    Viberg, Mats
    Xu, Guanghan
    2015 23RD EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2015, : 1336 - 1340
  • [38] Data Mining for Indoor Wave Propagation Model Calibration
    Aymen, Ben Zineb
    Ayadi, Mohamed
    2014 International Conference on Communications and Networking (ComNet), 2014,
  • [39] Installation and calibration of a parametric array for shallow water backscatter measurements
    Bergem, O
    Pace, NG
    OCEANS '96 MTS/IEEE, CONFERENCE PROCEEDINGS, VOLS 1-3 / SUPPLEMENTARY PROCEEDINGS: COASTAL OCEAN - PROSPECTS FOR THE 21ST CENTURY, 1996, : 773 - 777
  • [40] Fast and Accurate Array Calibration Using a Synthetic Array Approach
    Keizer, Will P. M. N.
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2011, 59 (11) : 4115 - 4122