Downstream processing from melt granulation towards tablets: In-depth analysis of a continuous twin-screw melt granulation process using polymeric binders

被引:33
|
作者
Grymonpre, W. [1 ]
Verstraete, G. [1 ]
Vanhoorne, V. [1 ]
Remon, J. P. [1 ]
De Beer, T. [2 ]
Vervaet, C. [1 ]
机构
[1] Univ Ghent, Lab Pharmaceut Technol, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
[2] Univ Ghent, Lab Pharmaceut Proc Analyt Technol, Ghent, Belgium
关键词
Continuous manufacturing; Twin-screw melt granulation; Polymeric binders; Tableting; Quality-by-design; Multivariate data analysis; CONTINUOUS DIRECT COMPRESSION; SOLID DISPERSIONS; VISCOELASTIC PROPERTIES; FORMULATION DEVELOPMENT; SOLUBILITY PARAMETERS; COMPACTION PROPERTIES; PRESS SIMULATOR; WET GRANULATION; EXTRUSION; EXTRUDER;
D O I
10.1016/j.ejpb.2017.12.005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The concept of twin-screw melt granulation (TSMG) has steadily (re)-gained interest in pharmaceutical formulation development as an intermediate step during tablet manufacturing. However, to be considered as a viable processing option for solid oral dosage forms there is a need to understand all critical sources of variability which could affect this granulation technique. The purpose of this study was to provide an in-depth analysis of the continuous TSMG process in order to expose the critical process parameters (CPP) and elucidate the impact of process and formulation parameters on the critical quality attributes (CQA) of granules and tablets during continuous TSMG. A first part of the study dealt with the screening of various amorphous polymers as binder for producing high-dosed melt granules of two model drug (i.e. acetaminophen and hydrochlorothiazide). The second part of this study described a quality-by-design (QbD) approach for melt granulation of hydrochlorothiazide in order to thoroughly evaluate TSMG, milling and tableting stage of the continuous TSMG line. Using amorphous polymeric binders resulted in melt granules with high milling efficiency due to their brittle behaviour without producing excessive amounts of fines, providing high granule yields with low friability. Therefore, it makes them extremely suitable for further downstream processing. One of the most important CPP during TSMG with polymeric binders was the granulation-torque, which-in case of polymers with high T-g-increased during longer granulation runs to critical levels endangering the continuous process flow. However, by optimizing both screw speed and throughput or changing to polymeric binders with lower T-g it was possible to significantly reduce this risk. This research paper highlighted that TSMG must be considered as a viable option during formulation development of solid oral dosage forms based on the robustness of the CQA of both melt granules and tablets.
引用
收藏
页码:43 / 54
页数:12
相关论文
共 35 条
  • [31] Application of Melt Granulation Technology Using Twin-screw Extruder in Development of High-dose Modified-release Tablet Formulation
    Vasanthavada, Madhav
    Wang, Yanfeng
    Haefele, Thomas
    Lakshman, Jay P.
    Mone, Manisha
    Tong, Weiqin
    Joshi, Yatindra M.
    Serajuddin, Abu T. M.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 100 (05) : 1923 - 1934
  • [32] Continuous, simultaneous cocrystallization and formulation of Theophylline and 4-Aminobenzoic acid pharmaceutical cocrystals using twin screw melt granulation
    Shaikh, Rahamatullah
    Walkers, Gavin M.
    Croker, Denise M.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 137
  • [33] Optimization of a Twin screw melt granulation process for fixed dose combination immediate release Tablets: Differential amorphization of one drug and crystalline continuance in the other
    Munnangi, Siva Ram
    Narala, Nagarjuna
    Lakkala, Preethi
    Vemula, Sateesh Kumar
    Narala, Sagar
    Johnson, Lindsay
    Karry, Krizia
    Repka, Michael
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2024, 665
  • [34] Development of Maltodextrin-Based Immediate-Release Tablets Using an Integrated Twin-Screw Hot-Melt Extrusion and Injection-Molding Continuous Manufacturing Process
    Puri, Vibha
    Brancazio, Dave
    Desai, Parind M.
    Jensen, Keith D.
    Chun, Jung-Hoon
    Myerson, Allan S.
    Trout, Bernhardt L.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2017, 106 (11) : 3328 - 3336
  • [35] Pre-plasticization of thermal binder facilitates processing and granule growth during melt granulation of gabapentin using co-rotating twin screw extruder
    Spahn, Jamie E.
    Zhang, Feng
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2020, 46 (12) : 1971 - 1978