Development of a metrological atomic force microscope for nano-scale standards calibration

被引:4
|
作者
Wang, S. H. [1 ]
Xu, G. [1 ]
Tan, S. L. [1 ]
机构
[1] Agcy Sci Technol & Res, Natl Metrol Ctr, Singapore 118221, Singapore
关键词
Laser interferometer; autocollimator; atomic force microscope; nanotechnology; nanometrology; step height; 1D/2D lateral pitch gratings;
D O I
10.1117/12.814517
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The rapid advancement of nanotechnology is increasingly demanding measurements carried out at nano-scale be more accurate, comparable and traceable to the international standards of units (the SI). The Atomic Force Microscope (AFM) is a very powerful tool for the measurement of surface texture and micro-/nano-structures, with wide applications in nanotechnology. However, the traceability and accuracy of quantitative measurements made by commercial AFMs are often questionable and large discrepancies among them have been reported. This paper describes a metrological AFM developed at the National Metrology Centre (NMC) which has a very large scanning range with nanometre uncertainty. In order to achieve direct traceability to the SI, the system was constructed by integrating an AFM probe with a 3-axis nano-translation stage furnished with high performance autocollimators and laser interferometers along its X, Y and Z axes on a metrological frame. The large scanning range (25 mm X 25 mm X 5 mm) enables the system to be used for surface inspection on much larger samples than those allowed in normal commercial AFMs. Details of the system design and operation will be described in the paper. The uncertainty evaluation was done using certified step height, 1D/2D lateral pitch gratings. The experimental results show that the system is capable of achieving an uncertainty in the order of a few nanometres, which demonstrates that the system is suitable for providing traceability to commercial scanning probe microscopes (SPMs) including AFMs through calibrated transfer artefacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Two-dimensional nanometer scale gratings measurement by metrological atomic force microscope
    Gao, Si-Tian
    Du, Hua
    Lu, Ming-Zhen
    Gui, Jian-Jun
    Jiliang Xuebao/Acta Metrologica Sinica, 2006, 27 (SUPPL.): : 6 - 10
  • [22] Step height measurement by the metrological atomic force microscope
    State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, Tianjin 300072, China
    不详
    不详
    Nami Jishu yu Jingmi Gongcheng, 2008, 4 (288-292):
  • [23] Design and characterization of MIKES metrological atomic force microscope
    Korpelainen, V.
    Seppa, J.
    Lassila, A.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2010, 34 (04): : 735 - 744
  • [24] Research on nano-scale material removal process using atomic force microscopy
    Zhang, Feihu
    Zhang, Huali
    Yan, Yongda
    Wang, Jinghe
    ADVANCES IN GRINDING AND ABRASIVE TECHNOLOGY XIV, 2008, 359-360 : 269 - 273
  • [25] Imaging and evaluation of nano-scale crack by using ultrasonic atomic force microscopy
    Tsuji, T
    Irihama, H
    Mihara, T
    Yamanaka, K
    ADVANCES IN FRACTURE AND FAILURE PREVENTION, PTS 1 AND 2, 2004, 261-263 : 1067 - 1072
  • [26] Real-time, interferometrically measuring atomic force microscope for direct calibration of standards
    Department of Mechanical Metrology, Natl. Res. Laboratory of Metrology, 1-1-4 Umezono, Tsukuba 305-8563, Japan
    不详
    Rev. Sci. Instrum., 8 (3362-3368):
  • [27] Real-time, interferometrically measuring atomic force microscope for direct calibration of standards
    Gonda, S
    Doi, T
    Kurosawa, T
    Tanimura, Y
    Hisata, N
    Yamagishi, T
    Fujimoto, H
    Yukawa, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (08): : 3362 - 3368
  • [28] Normal Force Calibration Method Used for Calibration of Atomic Force Microscope
    Ekwinska, M.
    Rymuza, Z.
    ACTA PHYSICA POLONICA A, 2009, 116 : S78 - S81
  • [29] Nano-scale structure of human erythrocyte membrane studied by atomic force microscopy
    Zhu, GH
    Feng, SS
    MOLECULAR BIOLOGY OF THE CELL, 1998, 9 : 160A - 160A
  • [30] Comparison and uncertainties of standards for critical dimension atomic force microscope tip width calibration
    Dixson, Ronald
    Orji, Ndubuisi G.
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXI, PTS 1-3, 2007, 6518