A spline Laplacian ECG estimator in a realistic geometry volume conductor

被引:0
|
作者
He, B
Li, GL
Lian, J
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL 60607 USA
[3] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
关键词
body surface Laplacian mapping; electrocardiography; inverse problem; Laplacian ECG; realistic geometry; regularization; spline Laplacian; surface Laplacian;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed, a spline-based Laplacian estimator over an arbitrarily shaped surface of a volume conductor and tested its applicability to Laplacian electrocardiogram (ECG) mappings In the newly developed algorithm, estimation of the parameters associated with the spline Laplacian is formulated by seeking the general inverse of a transfer matrix. Only one spline-parameter needs to be determined through regularization in order to estimate the realistic geometry surface Laplacian from the body surface potentials. It has been demonstrated that the rich knowledge on regularization in the inverse problems can be directly applied to estimate the spline Laplacian ECG (LECG), such as the discrepancy principle. Computer simulations have been conducted to validate the new approach in a spherical volume conductor and test the feasibility of mapping cardiac electrical sources in a realistic geometry heart-torso model. The present results demonstrate that the, realistic geometry spline LECG can be estimated conveniently from the body surface potentials, is more robust against measurement noise and has better performance than the conventional five-point local Laplacian estimator.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 38 条
  • [21] Randomly Generated Realistic Vessel Geometry using Spline Interpolation and 2D Perlin Noise
    Bizopoulos, Paschalis A.
    Sakellarios, Antonis I.
    Koutsouris, Dimitrios D.
    Iliopoulou, Dimitra
    Michalis, Lampros K.
    Fotiadis, Dimitrios I.
    2014 IEEE-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS (BHI), 2014, : 157 - 160
  • [22] Computational representation of a realistic head and brain volume conductor model: electroencephalography simulation and visualization study
    Kybartaite, Asta
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2012, 28 (11) : 1144 - 1155
  • [23] Combining EEG and MEG for the Reconstruction of Epileptic Activity Using a Calibrated Realistic Volume Conductor Model
    Aydin, Uemit
    Vorwerk, Johannes
    Kuepper, Philipp
    Heers, Marcel
    Kugel, Harald
    Galka, Andreas
    Hamid, Laith
    Wellmer, Joerg
    Kellinghaus, Christoph
    Rampp, Stefan
    Wolters, Carsten Hermann
    PLOS ONE, 2014, 9 (03):
  • [24] Cardiac vectors in the healthy human fetus: developmental changes assessed by magnetocardiography and realistic approximations of the volume conductor
    Tao, R.
    Popescu, E. A.
    Drake, W. B.
    Popescu, M.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (05) : 527 - 540
  • [25] AMPLITUDE AND POLARITY OF EARLY SOMATOSENSORY EVOKED-POTENTIAL COMPONENTS STUDIED WITH A REALISTIC VOLUME CONDUCTOR MODEL
    STEGEMAN, DF
    VANOOSTEROM, A
    NOTERMANS, SLH
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1987, 34 (3-4) : 258 - 258
  • [26] The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model
    Kirsten E. I. Deurloo
    Jan Holsheimer
    Piet Bergveld
    Biological Cybernetics, 2001, 85 : 281 - 291
  • [27] The effect of subthreshold prepulses on the recruitment order in a nerve trunk analyzed in a simple and a realistic volume conductor model
    Deurloo, KEI
    Holsheimer, J
    Bergveld, P
    BIOLOGICAL CYBERNETICS, 2001, 85 (04) : 281 - 291
  • [28] EFFECT OF VOLUME CONDUCTOR ON ELECTROCARDIOGRAM - EXPERIMENTAL STUDIES ON CHEST ECG CHANGES CAUSED BY VARIOUS INFLATION OF LUNG
    OKADA, A
    TOYAMA, J
    UCHIYAMA, O
    NAKANE, M
    WAKAYAMA, J
    OISHI, H
    MIZUNO, Y
    HIBINO, S
    NAGATA, Y
    KOBAYASH.T
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1968, 32 (12S): : 1826 - &
  • [29] COMPARISON OF VOLUME CONDUCTOR AND SOURCE GEOMETRY-EFFECTS ON BODY-SURFACE AND EPICARDIAL POTENTIALS
    RUDY, Y
    PLONSEY, R
    CIRCULATION RESEARCH, 1980, 46 (02) : 283 - 291
  • [30] Computation of Surface Laplacian for Tri-polar Ring Electrodes on High-density Realistic Geometry Head Model
    Ma, Junwei
    Yuan, Han
    Sunderam, Sridhar
    Besio, Walter
    Ding, Lei
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3616 - 3619