A spline Laplacian ECG estimator in a realistic geometry volume conductor

被引:0
|
作者
He, B
Li, GL
Lian, J
机构
[1] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL 60607 USA
[3] Univ Illinois, Dept Bioengn, Chicago, IL 60607 USA
关键词
body surface Laplacian mapping; electrocardiography; inverse problem; Laplacian ECG; realistic geometry; regularization; spline Laplacian; surface Laplacian;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed, a spline-based Laplacian estimator over an arbitrarily shaped surface of a volume conductor and tested its applicability to Laplacian electrocardiogram (ECG) mappings In the newly developed algorithm, estimation of the parameters associated with the spline Laplacian is formulated by seeking the general inverse of a transfer matrix. Only one spline-parameter needs to be determined through regularization in order to estimate the realistic geometry surface Laplacian from the body surface potentials. It has been demonstrated that the rich knowledge on regularization in the inverse problems can be directly applied to estimate the spline Laplacian ECG (LECG), such as the discrepancy principle. Computer simulations have been conducted to validate the new approach in a spherical volume conductor and test the feasibility of mapping cardiac electrical sources in a realistic geometry heart-torso model. The present results demonstrate that the, realistic geometry spline LECG can be estimated conveniently from the body surface potentials, is more robust against measurement noise and has better performance than the conventional five-point local Laplacian estimator.
引用
收藏
页码:110 / 117
页数:8
相关论文
共 38 条
  • [1] Realistic geometry Laplacian: A moderate spline estimation approach
    Zhai, YR
    Yao, DZ
    2005 First International Conference on Neural Interface and Control Proceedings, 2005, : 156 - 158
  • [2] A new realistic geometry spline Laplacian algorithm and its application to VEP
    Zhao, FQ
    Wu, DN
    Krumick, G
    Wu, DS
    He, B
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 2183 - 2185
  • [3] High-resolution EEG: a new realistic geometry spline Laplacian estimation technique
    He, B
    Lian, J
    Li, GL
    CLINICAL NEUROPHYSIOLOGY, 2001, 112 (05) : 845 - 852
  • [4] A simulation study of Laplacian ECG in a realistically shaped torso volume conductor: myocardial infarction
    Wu, D
    Schablowski, M
    Ono, K
    Hosaka, H
    He, B
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 47 (02): : 231 - 235
  • [5] THE INFLUENCE OF INHOMOGENEOUS VOLUME CONDUCTOR MODELS ON THE ECG AND THE MCG
    BRUDER, H
    SCHOLZ, B
    ABRAHAMFUCHS, K
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (11): : 1949 - 1968
  • [6] The volume conductor may act as a temporal filter on the ECG and EEG
    J. G. Stinstra
    M. J. Peters
    Medical and Biological Engineering and Computing, 1998, 36 : 711 - 716
  • [7] The volume conductor may act as a temporal filter on the ECG and EEG
    Stinstra, J.G.
    Peters, M.J.
    Medical and Biological Engineering and Computing, 1998, 36 (06): : 711 - 716
  • [8] The volume conductor may act as a temporal filter on the ECG and EEG
    Stinstra, JG
    Peters, MJ
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1998, 36 (06) : 711 - 716
  • [9] A realistic volume conductor model of the neonatal head: methods, challenges and applications
    Despotovic, Ivana
    Vansteenkiste, Ewout
    Philips, Wilfried
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3303 - 3306
  • [10] An improved boundary element method for realistic volume-conductor modeling
    Fuchs, M
    Drenckhahn, R
    Wischmann, HA
    Wagner, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (08) : 980 - 997