Diaphragm ultrasonography as an alternative to whole-body plethysmography in pulmonary function testing

被引:50
|
作者
Scott, S
Fuld, JP
Carter, R
McEntegart, M
MacFarlane, NG
机构
[1] Univ Glasgow, Ctr Exercise Sci & Med, Inst Biomed & Life Sci, Glasgow G12 8QQ, Lanark, Scotland
[2] Glasgow Royal Infirm, Dept Resp Med, Glasgow G4 0SF, Lanark, Scotland
[3] Univ Glasgow, Western Infirm, Dept Med Cardiol, Glasgow G11 6NT, Lanark, Scotland
关键词
diaphragm; plethysmography; ultrasonography;
D O I
10.7863/jum.2006.25.2.225
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Whole-body plethysmography is a common method of measuring pulmonary function. Although this technique provides a sensitive measure of pulmonary function, it can be problematic and unsuitable in some patients. The development of more accessible techniques would be beneficial. Methods. A prospective study was performed to validate diaphragm ultrasonography as an alternative to whole-body plethysmography in patients referred for pulmonary function testing. Diaphragm movement and position were assessed by ultrasonography after standard pulmonary function testing using whole-body plethysmography. Results. A wide range of lung function was observed. Standard lung volumes were as follows: total lung capacity, 5.57 +/- 1.31 L, residual volume, 2.27 +/- 0.56 L; and vital capacity, 3.30 +/- 0.98 L (mean SD). The ratio of forced expiratory volume in 1 second to forced vital capacity was calculated as 0.69 +/- 0.08. Ultrasonography showed that mean diaphragm excursion values were 11.1 +/- 3.8 mm (2-dimensional), 14.7 +/- 4.1 mm during quiet breathing (M-mode), and 14.8 +/- 3.9 mm during a maximal sniff (M-mode). The velocity of diaphragm movement rose sharply during the sniff maneuver from 15.2 +/- 5.8 mm/s during quiet breathing to 104.0 +/- 33.4 mm/s. Static 2-dimensional measures of diaphragm position at the end of quiet inspiration or expiration correlated with standard measures of lung volume on plethysmography (eg, a correlation coefficient of 0.83 was obtained with end inspiration and vital capacity). All measures of diaphragm movement (whether by 2-dimensional or M-mode techniques) were poorly correlated with any lung volumes measured. Conclusions. These data suggest that dynamic measurements using diaphragm ultrasonography provide a relatively poor measure of pulmonary function in relation to whole-body plethysmography.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [21] STUDY OF MEASUREMENT ON RESPIRATORY FUNCTION BY WHOLE-BODY PLETHYSMOGRAPHY (WBP) IN UNANESTHETIZED AND UNRESTRAINED MICROMINIPIGS
    Sasaki, Kazuaki
    Ma, Chengjun
    Imaizumi, Masakazu
    Atai, Hiroshi
    Nishi, Katsuhide
    [J]. JOURNAL OF PHARMACOLOGICAL SCIENCES, 2013, 121 : 210P - 210P
  • [22] Evaluation Of Body Composition Measurements Obtained Using Whole-body Plethysmography
    Macaulay, Timothy R.
    Uhlir, Conor D.
    Schroeder, E. Todd
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 161 - 161
  • [23] WHOLE-BODY PLETHYSMOGRAPHY AS AN AID IN DETERMINING THE EFFICACY OF BRONCHODILATORS IN HORSES WITH OBSTRUCTIVE PULMONARY-DISEASE
    BEADLE, RE
    [J]. PROCEEDINGS OF THE ANNUAL CONVENTION OF THE AMERICAN ASSOCIATION OF EQUINE PRACTITIONERS, 1980, 26 (NOV-): : 476 - 476
  • [24] Impulse oscillometry in COPD: Correlation to spirometry and whole-body plethysmography
    Vukoja, Marija
    Milicic, Dragana
    Kopitovic, Ivan
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [25] COMPUTER-AIDED INTERPRETATION OF THE RESULTS OF WHOLE-BODY PLETHYSMOGRAPHY
    ZAISS, AW
    WILLIM, G
    MATTHYS, H
    [J]. ATEMWEGS-UND LUNGENKRANKHEITEN, 1987, 13 (08) : 380 - 381
  • [26] Impulse oscillometry in COPD: Correlation to spirometry and whole-body plethysmography
    Vukoja, Marija
    Milicic, Dragana
    Kopitovic, Ivan
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2014, 44
  • [27] Measuring Breathing Patterns in Mice Using Whole-body Plethysmography
    Prada-Dacasa, Patricia
    Urpi, Andrea
    Sanchez-Benito, Laura
    Bianchi, Patrizia
    Quintana, Albert
    [J]. BIO-PROTOCOL, 2020, 10 (17):
  • [28] Use of whole-body plethysmography to compare bronchodilator inhaler efficacy
    Morice, AH
    Waterhouse, JC
    Peers, EM
    Parry-Billings, M
    [J]. RESPIRATION, 1998, 65 (02) : 120 - 124
  • [29] INHALATIONAL ANTIGEN INDUCTION TRIALS USING WHOLE-BODY PLETHYSMOGRAPHY
    GONSIOR, E
    KRUGER, M
    MEIERSYDOW, J
    [J]. ACTA ALLERGOLOGICA, 1976, 31 (04): : 283 - 296
  • [30] EXTERNAL RESPIRATION FUNCTION IN PATIENTS WITH BRONCHIAL-ASTHMA ACCORDING TO THE DATA OF THE WHOLE-BODY PLETHYSMOGRAPHY
    KALGANOVA, LY
    DANILYAK, IG
    ZINGER, EO
    GULYAEVA, FE
    [J]. TERAPEVTICHESKII ARKHIV, 1978, 50 (12): : 56 - 59