Diaphragm ultrasonography as an alternative to whole-body plethysmography in pulmonary function testing

被引:50
|
作者
Scott, S
Fuld, JP
Carter, R
McEntegart, M
MacFarlane, NG
机构
[1] Univ Glasgow, Ctr Exercise Sci & Med, Inst Biomed & Life Sci, Glasgow G12 8QQ, Lanark, Scotland
[2] Glasgow Royal Infirm, Dept Resp Med, Glasgow G4 0SF, Lanark, Scotland
[3] Univ Glasgow, Western Infirm, Dept Med Cardiol, Glasgow G11 6NT, Lanark, Scotland
关键词
diaphragm; plethysmography; ultrasonography;
D O I
10.7863/jum.2006.25.2.225
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. Whole-body plethysmography is a common method of measuring pulmonary function. Although this technique provides a sensitive measure of pulmonary function, it can be problematic and unsuitable in some patients. The development of more accessible techniques would be beneficial. Methods. A prospective study was performed to validate diaphragm ultrasonography as an alternative to whole-body plethysmography in patients referred for pulmonary function testing. Diaphragm movement and position were assessed by ultrasonography after standard pulmonary function testing using whole-body plethysmography. Results. A wide range of lung function was observed. Standard lung volumes were as follows: total lung capacity, 5.57 +/- 1.31 L, residual volume, 2.27 +/- 0.56 L; and vital capacity, 3.30 +/- 0.98 L (mean SD). The ratio of forced expiratory volume in 1 second to forced vital capacity was calculated as 0.69 +/- 0.08. Ultrasonography showed that mean diaphragm excursion values were 11.1 +/- 3.8 mm (2-dimensional), 14.7 +/- 4.1 mm during quiet breathing (M-mode), and 14.8 +/- 3.9 mm during a maximal sniff (M-mode). The velocity of diaphragm movement rose sharply during the sniff maneuver from 15.2 +/- 5.8 mm/s during quiet breathing to 104.0 +/- 33.4 mm/s. Static 2-dimensional measures of diaphragm position at the end of quiet inspiration or expiration correlated with standard measures of lung volume on plethysmography (eg, a correlation coefficient of 0.83 was obtained with end inspiration and vital capacity). All measures of diaphragm movement (whether by 2-dimensional or M-mode techniques) were poorly correlated with any lung volumes measured. Conclusions. These data suggest that dynamic measurements using diaphragm ultrasonography provide a relatively poor measure of pulmonary function in relation to whole-body plethysmography.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 50 条
  • [1] WHOLE-BODY PLETHYSMOGRAPHY
    MATTHYS, H
    [J]. PNEUMONOLOGIE-PNEUMONOLOGY, 1971, 146 (03): : 216 - &
  • [2] Whole-Body Plethysmography
    Criee, Carl-Peter
    [J]. MEDIZINISCHE KLINIK, 2010, 105 (09) : 652 - 660
  • [3] Whole-body plethysmography
    Criee, C. -P.
    [J]. PNEUMOLOGE, 2009, 6 (05): : 337 - 344
  • [4] Evaluation of pulmonary function in European land tortoises using whole-body plethysmography
    Schifino Valente, A. L.
    Martinez-Silvestre, A.
    Garcia-Guasch, L.
    Riera-Tort, A.
    Marco, I.
    Lavin, S.
    Cuenca, R.
    [J]. VETERINARY RECORD, 2012, 171 (06) : 154 - +
  • [5] Pulmonary function assessment by whole-body plethysmography in restrained versus unrestrained mice
    DeLorme, MP
    Moss, OR
    [J]. JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2002, 47 (01) : 1 - 10
  • [6] IMPROVEMENT IN WHOLE-BODY PLETHYSMOGRAPHY
    BRYANT, GH
    HANSEN, JE
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1975, 112 (03): : 464 - 465
  • [7] IMPROVEMENT IN WHOLE-BODY PLETHYSMOGRAPHY
    BRYANT, GH
    HANSEN, JE
    [J]. FEDERATION PROCEEDINGS, 1974, 33 (03) : 303 - 303
  • [8] Simultaneous visual inspection for barometric whole-body plethysmography waveforms during pulmonary function testing in client-owned cats
    Lin, Chung-Hui
    Wu, Huey-Dong
    Lo, Pei-Ying
    Lee, Jih-Jong
    Liu, Chen-Hsuan
    [J]. JOURNAL OF FELINE MEDICINE AND SURGERY, 2016, 18 (10) : 761 - 767
  • [9] Whole-body plethysmography [Ganzkörperplethysmographie]
    Criée C.-P.
    [J]. Der Pneumologe, 2009, 6 (5): : 337 - 345
  • [10] Whole-Body Plethysmography The Human Factor
    Bar-Yishay, Ephraim