Marker-based validation of a biplane fluoroscopy system for quantifying foot kinematics

被引:15
|
作者
Iaquinto, Joseph M. [1 ,2 ]
Tsai, Richard [1 ]
Haynor, David R. [3 ]
Fassbind, Michael J. [1 ]
Sangeorzan, Bruce J. [1 ,4 ]
Ledoux, William R. [1 ,2 ,4 ]
机构
[1] VA Puget Sound Hlth Care Syst, Dept Vet Affairs, RR&D Ctr Excellence Limb Loss Prevent & Prosthet, Seattle, WA USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA 98195 USA
[3] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[4] Univ Washington, Dept Orthopaed & Sports Med, Seattle, WA 98195 USA
关键词
Biplane fluoroscopy; X-ray; Foot; Biomechanics; MODEL;
D O I
10.1016/j.medengphy.2013.08.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Radiostereometric analysis has demonstrated its capacity to track precise motion of the bones within a subject during motion. Existing devices for imaging the body in two planes are often custom built systems: we present here the design and marker-based validation of a system that has been optimized to image the foot during gait. Methods: Mechanical modifications were made to paired BV Pulsera C-arms (Philips Medical Systems) to allow unfettered gait through the imaging area. Image quality improvements were obtained with high speed cameras and the correction of image distorting artifacts. To assess the system's accuracy, we placed beads at known locations throughout the imaging field, and used post processing software to calculate their apparent locations. Results: Distortion correction reduced overall RMS error from 6.56 mm to 0.17 mm. When tracking beads in static images a translational accuracy of 0.094 +/- 0.081 mm and rotational accuracy of 0.083 +/- 0.068 degrees was determined. In dynamic trials simulating speeds seen during walking, accuracy was 0.126 +/- 0.122 mm. Discussion: The accuracies and precisions found are within the reported ranges from other such systems. With the completion of marker-based validation, we look to model-based validation of the foot during gait. Published by Elsevier Ltd on behalf of IPEM.
引用
下载
收藏
页码:391 / 396
页数:6
相关论文
共 50 条
  • [1] DESIGN AND MARKER-BASED VALIDATION OF A BIPLANE FLUOROSCOPY SYSTEM FOR STUDYING THE FOOT AND ANKLE
    Iaquinto, Joseph M.
    Tsai, Richard
    Fassbind, Michael J.
    Haynor, David R.
    Sangeorzan, Bruce J.
    Ledoux, William R.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 193 - 194
  • [2] Preliminary marker-based validation of a novel biplane fluoroscopy system
    Joseph M Iaquinto
    Richard Tsai
    Michael Fassbind
    David R Haynor
    Bruce J Sangeorzan
    William R Ledoux
    Journal of Foot and Ankle Research, 5 (Suppl 1)
  • [3] Model-based tracking of the bones of the foot: A biplane fluoroscopy validation study
    Iaquinto, Joseph M.
    Kindig, Matthew W.
    Haynor, David R.
    Vu, QuocBao
    Pepin, Nathan
    Tsai, Richard
    Sangeorzan, Bruce J.
    Ledoux, William R.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 92 : 118 - 127
  • [4] Preliminary model-based validation of a biplane fluoroscopy system
    Joseph M Iaquinto
    Richard Tsai
    Quoc-Bao Vu
    David R Haynor
    Bruce J Sangeorzan
    William R Ledoux
    Journal of Foot and Ankle Research, 7 (Suppl 1)
  • [5] Validation of imaging-based quantification of glenohumeral joint kinematics using an unmodified clinical biplane fluoroscopy system
    Mozingo, Joseph D.
    Shandiz, Mohsen Akbari
    Marquez, Felicia M.
    Schueler, Beth A.
    Holmes, David R., III
    McCollough, Cynthia H.
    Zhao, Kristin D.
    JOURNAL OF BIOMECHANICS, 2018, 71 : 306 - 312
  • [6] Validation of a portable marker-based motion analysis system
    Wang, Shaobai
    Zeng, Xiaolong
    Liang Huangfu
    Xie, Zhenyan
    Ma, Limin
    Huang, Wenhan
    Zhang, Yu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [7] Validation of a portable marker-based motion analysis system
    Shaobai Wang
    Xiaolong Zeng
    Liang Huangfu
    Zhenyan Xie
    Limin Ma
    Wenhan Huang
    Yu Zhang
    Journal of Orthopaedic Surgery and Research, 16
  • [8] Marker-based foot posture assessment in children
    Catriona M Kerr
    Julie Stebbins
    Tim Theologis
    Amy B Zavatsky
    Journal of Foot and Ankle Research, 5 (Suppl 1)
  • [9] Statistical Shape Model-Based Femur Kinematics From Biplane Fluoroscopy
    Baka, N.
    de Bruijne, M.
    van Walsum, T.
    Kaptein, B. L.
    Giphart, J. E.
    Schaap, M.
    Niessen, W. J.
    Lelieveldt, B. P. F.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (08) : 1573 - 1583
  • [10] CT-based radiostereometric analysis for assessing mid- foot kinematics: precision compared with marker-based radiostereometry
    Poulsen, Magnus
    Stodle, Are H.
    Nordsletten, Lars
    Rohrl, Stephan M.
    ACTA ORTHOPAEDICA, 2023, 94 : 366 - 372