Extraction of Blood Vessels in Retinal Images Using Resampling High-Order Background Estimation

被引:2
|
作者
Paripurana, Sukritta [1 ]
Chiracharit, Werapon [1 ]
Chamnongthai, Kosin [1 ]
Saito, Hideo [2 ]
机构
[1] King Mongkuts Univ Technol Thonburi, Fac Engn, Dept Elect & Telecommun Engn, Bangkok 10140, Thailand
[2] Keio Univ, Fac Sci & Technol, Dept Informat & Comp Sci, Yokohama, Kanagawa 2238522, Japan
来源
IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS | 2015年 / E98D卷 / 03期
关键词
retinal blood vessel extraction; retinal background estimation; rescaling image; high order degree polynomial; MICROVASCULAR ABNORMALITIES; ATHEROSCLEROSIS RISK; GRAY-LEVEL; SEGMENTATION; CLASSIFICATION; FUNDUS; COMMUNITIES; DISEASE;
D O I
10.1587/transinf.2014EDP7186
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In retinal blood vessel extraction through background removal, the vessels in a fundus image which appear in a higher illumination variance area are often missing after the background is removed. This is because the intensity values of the vessel and the background are nearly the same. Thus, the estimated background should be robust to changes of the illumination intensity. This paper proposes retinal blood vessel extraction using background estimation. The estimated background is calculated by using a weight surface fitting method with a high degree polynomial. Bright pixels are defined as unwanted data and are set as zero in a weight matrix. To fit a retinal surface with a higher degree polynomial, fundus images are reduced in size by different scaling parameters in order to reduce the processing time and complexity in calculation. The estimated background is then removed from the original image. The candidate vessel pixels are extracted from the image by using the local threshold values. To identify the true vessel region, the candidate vessel pixels are dilated from the candidate. After that, the active contour without edge method is applied. The experimental results show that the efficiency of the proposed method is higher than the conventional low-pass filter and the conventional surface fitting method. Moreover, rescaling an image down using the scaling parameter at 0.25 before background estimation provides as good a result as a non-rescaled image does. The correlation value between the non-rescaled image and the rescaled image is 0.99. The results of the proposed method in the sensitivity, the specificity, the accuracy, the area under the receiver operating characteristic (ROC) curve (AUC) and the processing time per image are 0.7994, 0.9717, 0.9543, 0.9676 and 1.8320 seconds for the DRIVE database respectively.
引用
收藏
页码:692 / 703
页数:12
相关论文
共 50 条
  • [31] Blood Vessels and Feature Points Detection on Retinal Images
    Ardizzone, Edoardo
    Pirrone, Roberto
    Gambino, Orazio
    Radosta, Salvatore
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2246 - 2249
  • [32] Effective combined Algorithms for retinal blood vessels extraction
    Zhou, Y. (quanquan1987727@126.com), 2012, Advanced Institute of Convergence Information Technology (04):
  • [33] Atrial fibrillatory signal estimation using blind source extraction algorithm based on high-order statistics
    Wang Gang
    Rao Nini
    Zhang Ying
    SCIENCE IN CHINA SERIES F-INFORMATION SCIENCES, 2008, 51 (10): : 1572 - 1584
  • [34] Atrial fibrillatory signal estimation using blind source extraction algorithm based on high-order statistics
    WANG Gang1
    2 School of Automation Engineering
    ScienceinChina(SeriesF:InformationSciences), 2008, (10) : 1572 - 1584
  • [35] New techniques for segmentation and extraction retinal blood vessels
    Erwin
    Rohman, A.
    Nurjanah, L. A.
    Yurika
    Sinta, D.
    Al'afwa, Q.
    3RD FORUM IN RESEARCH, SCIENCE, AND TECHNOLOGY (FIRST 2019) INTERNATIONAL CONFERENCE, 2020, 1500
  • [36] High-Order Entropy Coding for Images
    Tzou, Kou-Hu
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 1992, 2 (01) : 87 - 89
  • [37] Atrial fibrillatory signal estimation using blind source extraction algorithm based on high-order statistics
    Gang Wang
    NiNi Rao
    Ying Zhang
    Science in China Series F: Information Sciences, 2008, 51 : 1572 - 1584
  • [38] Automated blood vessel extraction using local features on retinal images
    Hatanaka, Yuji
    Samo, Kazuki
    Tajima, Mikiya
    Ogohara, Kazunori
    Muramatsu, Chisako
    Okumura, Susumu
    Fujita, Hiroshi
    MEDICAL IMAGING 2016: COMPUTER-AIDED DIAGNOSIS, 2015, 9785
  • [39] Virtual Blood Vessels in Complex Background using Stereo X-ray Images
    Chen, Qiuyu
    Bise, Ryoma
    Gu, Lin
    Zheng, Yinqiang
    Sato, Imari
    Hwang, Jenq-Neng
    Imanishi, Nobuaki
    Aiso, Sadakazu
    2017 IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW 2017), 2017, : 99 - 106
  • [40] Voice Jitter Estimation Using High-Order Synchrosqueezing Operators
    Miramont, Juan M.
    Colominas, Marcelo Alejandro
    Schlotthauer, Gaston
    IEEE-ACM TRANSACTIONS ON AUDIO SPEECH AND LANGUAGE PROCESSING, 2021, 29 : 527 - 536