Apoptosis detection in brain using low-magnification dark-field microscopy

被引:13
|
作者
Lange, MS [1 ]
Johnston, MV
Tseng, EE
Baumgartner, WA
Blue, ME
机构
[1] Johns Hopkins Univ, Sch Med, Kennedy Krieger Inst, Baltimore, MD 21205 USA
[2] Johns Hopkins Univ, Sch Med, Dept Neurol, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Sch Med, Dept Pediat, Baltimore, MD 21205 USA
[4] Johns Hopkins Univ, Sch Med, Div Cardiac Surg, Baltimore, MD 21205 USA
关键词
programmed cell death; ischemia; Nissl; neuropathology; development;
D O I
10.1006/exnr.1999.7097
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Apoptosis or programmed cell death is a feature of normal brain development and a response to brain injury. Cells undergoing apoptosis have a characteristic morphology that normally can only be appreciated at high magnification. Using dark-field transmitted light microscopy to examine Nissl-stained material, we detected groups of apoptotic cells at much lower magnifications than often were required in the two injury models we tested. This method was useful for screening entire brain sections to assess regional and global patterns of injury. We predict that this technique in which we detect the clumped chromatin associated with apoptosis can be applied to other types of tissue. (C) 1999 Academic Press.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [31] EXAMINATION OF BACTERIAL FLAGELLATION BY DARK-FIELD MICROSCOPY
    MACNAB, RM
    JOURNAL OF CLINICAL MICROBIOLOGY, 1976, 4 (03) : 258 - 265
  • [32] CONFOCAL SCANNING DARK-FIELD POLARIZATION MICROSCOPY
    KIMURA, S
    WILSON, T
    APPLIED OPTICS, 1994, 33 (07): : 1274 - 1278
  • [33] DISLOCATION INVISIBILITY IN DARK-FIELD ELECTRON MICROSCOPY
    DINGLEY, DJ
    PHYSICA STATUS SOLIDI, 1970, 38 (01): : 345 - &
  • [34] ULTRASENSITIVE DARK-FIELD LIGHT-MICROSCOPY
    ISHIHARA, A
    SEIKAGAKU, 1981, 53 (01): : 30 - 32
  • [35] DARK-FIELD AGAR MICROSCOPY OF BACTERIA MOTILITY
    ORSKOV, J
    ACTA PATHOLOGICA ET MICROBIOLOGICA SCANDINAVICA, 1950, 27 (05): : 767 - 769
  • [36] Plasmon mediated confocal dark-field microscopy
    Schmelzeisen, Marcus
    Austermann, Jacqueline
    Kreiter, Maximilian
    OPTICS EXPRESS, 2008, 16 (22) : 17826 - 17841
  • [37] Assessment and correction of geometric distortions in low-magnification scanning electron microscopy images
    Marschallinger, R
    Topa, D
    SCANNING, 1997, 19 (01) : 36 - 41
  • [38] SAMPLING OF SUBGINGIVAL MICROBIOTA FOR DARK-FIELD MICROSCOPY
    MAGNUSSON, I
    LILJENBERG, B
    YONEYAMA, T
    BLOMQVIST, N
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1985, 12 (03) : 209 - 215
  • [39] Microscopy refocusing and dark-field imaging by using a simple LED array
    Zheng, Guoan
    Kolner, Christopher
    Yang, Changhuei
    OPTICS LETTERS, 2011, 36 (20) : 3987 - 3989
  • [40] Dark-field digital holographic microscopy by using vortex beam illumination
    Zhao Ying-Chun
    Zhang Xiu-Ying
    Yuan Cao-Jin
    Nie Shou-Ping
    Zhu Zhu-Qing
    Wang Lin
    Li Yang
    Gong Li-Ping
    Feng Shao-Tong
    ACTA PHYSICA SINICA, 2014, 63 (22)