Interference Screw Versus Suture Anchor Fixation for Subpectoral Tenodesis of the Proximal Biceps Tendon: A Cadaveric Study

被引:94
|
作者
Golish, S. Raymond [2 ]
Caldwell, Paul E. [3 ]
Miller, Mark D. [2 ]
Singanamala, Naveen [3 ]
Ranawat, Anil S. [4 ]
Treme, Gehron [2 ]
Pearson, Sara E. [3 ]
Costic, Ryan [4 ]
Sekiya, Jon K. [1 ]
机构
[1] Univ Michigan, Dept Orthoped Surg, Ann Arbor, MI 48106 USA
[2] Univ Virginia, Dept Orthopaed Surg, Charlottesville, VA USA
[3] Orthopaed Res Virginia, Richmond, VA USA
[4] Univ Pittsburgh, Dept Orthopaed Surg, Pittsburgh, PA USA
关键词
Biceps brachii; Tenodesis; Subpectoral; Bone screw; Suture anchors; Proximal;
D O I
10.1016/j.arthro.2008.05.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to compare the biomechanical properties of 2 fixation methods for subpectoral proximal biceps tenodesis. Methods: In 9 matched pairs of cadaveric shoulders, an open subpectoral tenodesis was performed I cm proximal to the inferior border of the pectoralis major tendon by use of either an 8 x 12-mm Bio-Tenodesis screw (Arthrex, Naples, FL) with No. 2 FiberWire sutures (Arthrex) or a 5.5-mm Bio-Corkscrew double-loaded suture anchor (Arthrex) with No. 2 FiberWire sutures. The specimens were dissected and mounted in a material testing machine. Cyclic loading (20 to 60 N, 100 cycles, 0.5 mm/s, 5-N preload) was performed, followed by an unloaded 30-minute rest, a 5-N preload, and a load-to-failure protocol (1.25 mm/s) with a 100-lb load cell. Ultimate load (in Newtons), stiffness (in Newtons per millimeter), and modes of failure were recorded. Data were analyzed by use of paired t tests and Wilcoxon signed rank tests. Results: Proximal biceps tenodeses with Bio-Tenodesis screws had a significantly higher mean load to failure (169.6 +/- 50.5 N; range, 99.6 to 244.7 N) than those with Bio-Corkscrew suture anchors (68.5 +/- 33.0 N; range, 24.2 to 119.4 N) (P = .002). Bio-Tenodesis screws also had a significantly higher stiffness (34.1 +/- 9.0 N/mm; range, 20.6 to 48.9 N/mm) than Bio-Corkscrews (19.3 +/- 10.5; range, 5.9 to 32.9 N/mm) (P = .038). Conclusions: In this cadaveric study the Bio-Tenodesis screw showed a statistically significantly higher load to failure and significantly higher stiffness than the Bio-Corkscrew anchor when used for tenodesis of the proximal biceps tendon in a subpectoral location. Clinical Relevance: Biomechanical comparison of these 2 fixation techniques provides information on stiffness and load to failure of alternate fixation methods.
引用
收藏
页码:1103 / 1108
页数:6
相关论文
共 50 条
  • [41] Biomechanical characterization of unicortical button fixation: a novel technique for proximal subpectoral biceps tenodesis
    Joseph P. DeAngelis
    Alvin Chen
    Michael Wexler
    Benjamin Hertz
    Leandro Grimaldi Bournissaint
    Ara Nazarian
    Arun J. Ramappa
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1434 - 1441
  • [42] Biomechanical characterization of unicortical button fixation: a novel technique for proximal subpectoral biceps tenodesis
    DeAngelis, Joseph P.
    Chen, Alvin
    Wexler, Michael
    Hertz, Benjamin
    Bournissaint, Leandro Grimaldi
    Nazarian, Ara
    Ramappa, Arun J.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (05) : 1434 - 1441
  • [43] Nerve Proximity During Bicortical Drilling for Subpectoral Biceps Tenodesis: A Cadaveric Study
    Ding, David Y.
    Gupta, Asheesh
    Snir, Nimrod
    Wolfson, Theodore
    Meislin, Robert J.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (08): : 942 - 946
  • [44] Anatomy of the Biceps Tendon: Implications for Restoring Physiological Length-Tension Relation During Biceps Tenodesis With Interference Screw Fixation
    Denard, Patrick J.
    Dai, Xuesong
    Hanypsiak, Brian T.
    Burkhart, Stephen S.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2012, 28 (10): : 1352 - 1358
  • [45] Mini-Open Subpectoral Biceps Tenodesis Using a Suture Anchor with Bone-Bridge Backup
    Dela Rueda, Therese
    Del Sol, Shane Rayos
    Perinovic, Steven
    Tse, Whitney
    Bryant, Stewart
    Gardner, Brandon
    Chakrabarti, Moyukh O.
    McGahan, Patrick J.
    Chen, James L.
    ARTHROSCOPY TECHNIQUES, 2021, 10 (12): : E2639 - E2644
  • [46] An analysis of the biomechanics of interference screw fixation and sheathed devices for biceps tenodesis
    Saithna, Adnan
    Chizari, Mahmoud
    Morris, Guy
    Anley, Cameron
    Wang, Bin
    Snow, Martyn
    CLINICAL BIOMECHANICS, 2015, 30 (06) : 551 - 557
  • [47] Arthroscopic biceps tenodesis with interference screw fixation: The lateral decubitus position
    Richards, DP
    Burkhart, SS
    Lo, IKY
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (01) : 15 - 23
  • [48] Biomechanical comparison of two techniques for arthroscopic suprapectoral biceps tenodesis: interference screw versus implant-free intraosseous tendon fixation
    Sampatacos, Nels
    Getelman, Mark H.
    Henninger, Heath B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (11) : 1731 - 1739
  • [49] Long Head of the Biceps Tendon Tenotomy versus Subpectoral Tenodesis in Rotator Cuff Repair
    Kim, Jangwoo
    Nam, Ji Hoon
    Kim, Yuna
    Kim, Jong Seop
    Kim, Sae Hoon
    CLINICS IN ORTHOPEDIC SURGERY, 2020, 12 (03) : 371 - 378
  • [50] Complications following subpectoral biceps tenodesis with interference screw fixation [Komplikationen nach subpektoraler Bizepstenodese und Fixierung mit Interferenzschrauben]
    Millett P.J.
    Rios D.
    Martetschläger F.
    Horan M.P.
    Obere Extremität, 2014, 9 (4) : 276 - 279