The conventional versus automated measurement of blood pressure in the office (CAMBO) trial: masked hypertension sub-study

被引:38
|
作者
Myers, Martin G. [1 ]
Godwin, Marshall [2 ]
Dawes, Martin [3 ]
Kiss, Alexander [4 ]
Tobe, Sheldon W. [5 ]
Kaczorowski, Janusz [6 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Schulich Heart Program, Div Cardiol, Toronto, ON M4N 3M5, Canada
[2] Mem Univ Newfoundland, Dept Family Med, St John, NF, Canada
[3] Univ British Columbia, Dept Family Med, Vancouver, BC V5Z 1M9, Canada
[4] Sunnybrook Hlth Sci Ctr, Dept Res Design & Biostat, Toronto, ON M4N 3M5, Canada
[5] Sunnybrook Hlth Sci Ctr, Div Nephrol, Toronto, ON M4N 3M5, Canada
[6] Univ Montreal, Dept Med Familiale & Med Urgence, Montreal, PQ, Canada
关键词
blood pressure measurement; hypertension diagnosis; masked hypertension; PREVALENCE;
D O I
10.1097/HJH.0b013e328356abd3
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objectives: To determine the prevalence of masked hypertension [normal office blood pressure (BP) with high awake ambulatory BP] using automated office BP (AOBP) or conventional manual office BP (MOBP) measurement in routine clinical practice. Methods: The prevalence of masked hypertension was evaluated on three consecutive visits during a median 6 months period in patients with systolic hypertension randomized to management with AOBP (n = 140) or continued conventional MOBP (n = 112) in routine primary care practice. AOBP was recorded using the automated BpTRU device with the patient resting alone in a quiet examining room. All patients underwent 24-h ambulatory BP monitoring. Results: The prevalence of masked hypertension on any one of three visits calculated using only SBP varied between 12 and 17% in the AOBP group compared with 19 and 22% in the MOBP group. Masked hypertension was present on both of the first two visits in 7 and 12% and on all three visits in 6 and 7% of AOBP and MOBP patients, respectively. The prevalence for masked hypertension based upon both SBP and DBP was similar being 11-15% for AOBP and 19-20% for MOBP patients on single visits, but decreased to 6 and 10% when readings from the first two visits were used and to 4 and 6% when all three visits were used for the AOBP and MOBP groups, respectively. Conclusion: The prevalence of masked hypertension is lower with AOBP compared with MOBP. The number of patients with masked hypertension decreases if the criteria for having this condition need to be met on multiple visits.
引用
收藏
页码:1937 / 1941
页数:5
相关论文
共 50 条
  • [1] Conventional versus automated measurement of blood pressure in the office (CAMBO) trial
    Myers, Martin G.
    Godwin, Marshall
    Dawes, Martin
    Kiss, Alexander
    Tobe, Sheldon W.
    Kaczorowski, Janusz
    [J]. FAMILY PRACTICE, 2012, 29 (04) : 376 - 382
  • [2] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT VERSUS CLASSIC OFFICE AUTOMATED BLOOD PRESSURE MEASUREMENT IN A HYPERTENSION OUTPATIENT CLINIC
    Legrady, Peter
    Fejes, Imola
    Czombos, Andras
    Abraham, Gyorgy
    [J]. JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E99 - E99
  • [3] Prevalence of masked hypertension in attended versus unattended office blood pressure measurement
    Bertram, Sebastian
    Bauer, Frederic
    Shadi, Roni
    Seidel, Maximilian
    Doevelaar, Adrian
    Seibert, Felix
    Babel, Nina
    Westhoff, Timm H.
    [J]. JOURNAL OF CLINICAL HYPERTENSION, 2024, 26 (06): : 615 - 623
  • [4] PREVALENCE OF MASKED HYPERTENSION ON REPEAT VISITS USING AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT
    Myers, M. G.
    Valdivieso, M.
    Kiss, A.
    [J]. JOURNAL OF HYPERTENSION, 2009, 27 : S328 - S328
  • [5] Automated office versus home measurement of blood pressure in the assessment of morning hypertension
    Andreadis, Emmanuel A.
    Angelopoulos, Epameinondas T.
    Tsakanikas, Athanasios P.
    Agaliotis, Gerasimos D.
    Kravvariti, Sofia D.
    Mousoulis, George P.
    [J]. BLOOD PRESSURE MONITORING, 2012, 17 (01) : 24 - 34
  • [6] Automated Office Blood Pressure Measurement for the Diagnosis of Hypertension
    Filler, Guido
    de Ferris, Maria E. Diaz-Gonzalez
    [J]. JOURNAL OF PEDIATRICS, 2020, 227 : 10 - 12
  • [7] Automated office blood pressure measurement increases prevalence of masked hypertension in patients with obstructive sleep apnoea
    Sova, Milan
    Genzor, Samuel
    Sovova, Eliska
    Sovova, Marketa
    Moravcova, Katarina
    Nadjarpour, Shayan
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2020, 56
  • [8] Attended versus unattended automated office blood pressure measurement in the diagnosis and treatment of hypertension
    Myers, Martin G.
    Sierra, Alejandro de La
    Roerecke, Michael
    Kaczorowski, Janusz
    [J]. JOURNAL OF HYPERTENSION, 2020, 38 (08) : 1407 - 1411
  • [9] Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial
    Myers, Martin G.
    Godwin, Marshall
    Dawes, Martin
    Kiss, Alexander
    Tobe, Sheldon W.
    Grant, F. Curry
    Kaczorowski, Janusz
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2011, 342 : 372
  • [10] Automated Office Blood Pressure Measurement
    Myers, Martin G.
    [J]. KOREAN CIRCULATION JOURNAL, 2018, 48 (04) : 241 - 250