Cross-strip anodes for microchannel plate detectors

被引:15
|
作者
Siegmund, OHW [1 ]
Tremsin, AS [1 ]
Abiad, R [1 ]
Vallerga, JV [1 ]
机构
[1] Univ Calif Berkeley, Space Sci Lab, Berkeley, CA 94720 USA
关键词
photon counting; microchannel plate; imaging; position readout;
D O I
10.1117/12.450071
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The cross strip anode is a coarse (0.5 mm) multi-layer metal and ceramic cross strip pattern. Event positions are encoded by direct sensing of the charge on each strip and subsequent determination of the charge cloud centroid for each event. This event position encoding is accomplished with chip preamplifiers on the anode, subsequent analog to digital conversion of individual strip charge values and a software centroid determination. The spatial resolution (<5 mum) achieved for an 8 x 8mm anode is sufficient to resolve 7mum microchannel plate pores while using low MCP gain (approximate to2 X 106) in an MCP pair configuration. The image linearity is good enough to enable distortions in the microchannel plate pore pattern to be seen as well as dead and distorted pores. The low MCP gain will enhance the local counting rate capacity and overall lifetime of a microchannel plate detector system with cross strip readout. We discuss plans for fabrication of a 32mm x 32mm anode with custom chip electronics so that encoding may be accomplished at photon counting rates >1 MHz and with low power consumption (similar to2W) suitable for applications in space astrophysics.
引用
收藏
页码:131 / 140
页数:10
相关论文
共 50 条
  • [31] MICROCHANNEL PLATE PORE-SIZE LIMITED IMAGING WITH ULTRA-THIN WEDGE AND STRIP ANODES
    LAPINGTON, JS
    SMITH, AD
    WALTON, DM
    SCHWARZ, HE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 431 - 433
  • [32] MICROCHANNEL PLATE PORE SIZE LIMITED IMAGING WITH ULTRA-THIN WEDGE AND STRIP ANODES.
    Lapington, J.S.
    Smith, A.D.
    Walton, D.M.
    Schwarz, H.E.
    IEEE Transactions on Nuclear Science, 1986, NS-34 (01) : 431 - 433
  • [33] Cross delay line microchannel plate detectors for the Spectrographic Imager on the IMAGE satellite
    Stock, JM
    Siegmund, OHW
    Hull, JS
    Kromer, KE
    Jelinsky, SR
    Heetderks, HD
    Lampton, ML
    Mende, SB
    EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 : 407 - 414
  • [34] Development of UV Imaging Detectors with Atomic Layer Deposited Microchannel Plates and Cross Strip Readouts
    Siegmund, O. H. W.
    McPhate, J. B.
    Curtis, T.
    Darling, N.
    Vallerga, J. V.
    Cremer, T.
    Ertley, C.
    X-RAY, OPTICAL, AND INFRARED DETECTORS FOR ASTRONOMY IX, 2020, 11454
  • [35] Developments in imaging devices for microchannel plate detectors
    Lapington, JS
    FUTURE EUV/UV AND VISIBLE SPACE ASTROPHYSICS MISSIONS AND INSTRUMENTATION, 2003, 4854 : 191 - 202
  • [36] Characterization of efficiency enhancement in microchannel plate detectors
    Sijbrandij, SJ
    Cerezo, A
    Deconihout, B
    Godfrey, TJ
    Smith, GDW
    JOURNAL DE PHYSIQUE IV, 1996, 6 (C5): : 297 - 302
  • [37] Energy dependent sensitivity of microchannel plate detectors
    Rochau, G. A.
    Bailey, J. E.
    Chandler, G. A.
    Nash, T. J.
    Nielsen, D. S.
    Dunham, G. S.
    Garcia, O. F.
    Joseph, N. R.
    Keister, J. W.
    Madlener, M. J.
    Morgan, D. V.
    Moy, K. J.
    Wu, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [38] Modeling microchannel plate detectors for improved performance
    Desouza, Romualdo
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [39] Functional proteomics using microchannel plate detectors
    Richards, P
    Lees, J
    PROTEOMICS, 2002, 2 (03) : 256 - 261
  • [40] Calibration of 3D positioning in a Ge cross-strip detector
    Amrose, S
    Boggs, SE
    Coburn, W
    Lin, RP
    Smith, DM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 170 - 173