EXPERIMENTAL INVESTIGATIONS AND IMPROVEMENTS FOR THE 10 K G-M REFRIGERATOR

被引:0
|
作者
Hao, X. H. [1 ]
Ju, Y. L. [1 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
关键词
G-M refrigerator; rectification meshes; labyrinth sealing; pressure; REGENERATOR MATERIALS; CRYOCOOLERS; DISPLACER;
D O I
10.1063/1.4706979
中图分类号
O59 [应用物理学];
学科分类号
摘要
With the wide application of high performance cryo-pumps, high and low temperature superconducting devices, MRI, infrared detectors and cryogenic electronics, the development of high efficient and reliable 10 K G-M refrigerator is of critical importance and awaited by cryogenic industries. In the past two years, systematic studies have been carried out, and detailed experimental tests indicated that the cooling performance of the 10 K G-M refrigerator was improved by adding two additional rectification meshes inside the low temperature regenerator and by optimizing the system charge pressure. Furthermore, a new labyrinth sealing displacer was proposed and fabricated to substitute the traditional piston-ring sealing displacer for improved operating stability and reliability of the 10 K GM refrigerator. The detailed experimental results and improvements were summarized and their optimal cases were given in this paper.
引用
收藏
页码:683 / 689
页数:7
相关论文
共 50 条
  • [31] CAPABILITY OF OBTAINING EXTREME HIGH-VACUUM BY COMMERCIAL G-M REFRIGERATOR-COOLED CRYOPUMP
    KIKUCHI, T
    OHSAKO, N
    HAYASHI, Y
    VACUUM, 1990, 41 (7-9) : 1941 - 1943
  • [32] 高温超导用10 K单级G-M制冷机性能研究
    周志坡
    何韩军
    朱良友
    李奥
    董文庆
    低温工程, 2023, (05) : 69 - 74
  • [33] DESIGN OF METAL G-M COUNTERS
    SHAMOS, MH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1947, 18 (08): : 586 - 587
  • [34] CHARACTERISTIC ANALYSIS OF G-M COUNTERS
    SHUMSHUROV, VI
    TELTSOV, MV
    ZUEVA, ZG
    ANTROPOV, AN
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 3 FIZIKA ASTRONOMIYA, 1982, 23 (05): : 50 - 55
  • [35] Dimension matrix of the G-M fractal
    Kim, Tae Sik
    Korean Journal of Computational & Applied Mathematics, 1998, 5 (01): : 13 - 22
  • [36] CORRECTION OF G-M COUNTER DATA
    KURBATOV, JD
    MANN, HB
    PHYSICAL REVIEW, 1945, 68 (1-2): : 40 - 43
  • [37] Design and experimental investigation of the high efficiency 1.5 W/4.2 K pneumatic-drive G-M cryocooler
    Hao, X. H.
    Yao, S. H.
    Schilling, T.
    CRYOGENICS, 2015, 70 : 28 - 33
  • [38] AUTOMATIC TESTER FOR G-M TUBES
    STREIT, GH
    KENNEDY, WR
    NUCLEONICS, 1952, 10 (06): : 61 - 62
  • [39] TESTS ON SCINTILLATION G-M TUBES
    DAGGS, VM
    PARR, WH
    KREBS, AT
    NUCLEONICS, 1952, 10 (01): : 54 - 55
  • [40] PULSED G-M TUBE OPERATION
    LICHTMAN, SW
    NUCLEONICS, 1953, 11 (01): : 22 - 27