A highly selective solid-contact electrode for Ag+ based on a monoazathiacrown ether ionophore

被引:9
|
作者
Yu, Shun Yang [1 ]
Ju, Lan [2 ]
Li, Fu Hai [1 ,3 ]
Liu, Yong Ming [3 ]
Fang, Jun Feng [4 ]
机构
[1] Chinese Acad Sci, Yantai Inst Coastal Zone Res, Key Lab Coastal Zone Environm Proc, Yantai 264003, Peoples R China
[2] Zhejiang Text & Fash Coll, Ningbo 315211, Zhejiang, Peoples R China
[3] Yantai Univ, Chem & Chem Engn Coll, Yantai 264005, Peoples R China
[4] Chinese Acad Sci, Ningbo Inst Mat Technol & Engn, Ningbo 315201, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Solid contact; Silver; Ion-selective electrodes; Low detection limit; MEMBRANE ELECTRODES; STABILITY;
D O I
10.1016/j.cclet.2011.12.016
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A new solid-contact Ag+-selective electrode was prepared with 9,10,12,13,24,25-hexahydro-5H,15H,23H-dibenzo[b,q][1,7,10,13,19,4,16]-entathiadiazacyclodocosine-6,16(7H,17H)-dione as ionophore, and alpha,omega-dihexylsexithiophene (DH-6T) ion-to-electron transducer. The sensor exhibited a working concentration range of 10(-8) to 10(-3) mol/L, with a near-Nemstian slope of 55.1 +/- 0.2 mV/dec and detection limit of 1.7 x 10(-9) mol/L. The fabricated electrodes demonstrated excellent selectivity over the most common monovalent and divalent cations. (C) 2011 Shun Yang Yu. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.
引用
收藏
页码:488 / 491
页数:4
相关论文
共 50 条
  • [21] Conventional and solid-contact lithium-selective electrodes based on tris[(N,N-dicyclohexylamide) neutral ionophore
    Grekovich, AL
    Markuzina, NN
    Mikhelson, KN
    Bochenska, M
    Lewenstam, A
    ELECTROANALYSIS, 2002, 14 (7-8) : 551 - 555
  • [22] POTENTIOMETRIC DETERMINATION OF MOLYBDENUM(VI) WITH A SOLID-CONTACT MOLYBDENUM-SELECTIVE ELECTRODE
    SHPIGUN, LK
    ABANINA, EN
    SHEINA, NM
    GALLAI, ZA
    INDUSTRIAL LABORATORY, 1988, 54 (02): : 122 - 125
  • [23] Microcavity based solid-contact ion-selective microelectrodes
    Sundfors, Fredrik
    Bereczki, Robert
    Bobacka, Johan
    Toth, Klara
    Ivaska, Ari
    Gyurcsanyi, Robert E.
    ELECTROANALYSIS, 2006, 18 (13-14) : 1372 - 1378
  • [24] A Solid-Contact Indium(III) Sensor based on a Thiosulfinate Ionophore Derived from Omeprazole
    Abbas, Mohammad Nooredeen
    Amer, Hend Samy
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2013, 34 (04): : 1153 - 1159
  • [25] Solid-contact potentiometric sensor for ascorbic acid based on cobalt phthalocyanine nanoparticles as ionophore
    Wang, K
    Xu, JJ
    Tang, KS
    Chen, HY
    TALANTA, 2005, 67 (04) : 798 - 805
  • [26] Potassium ion-selective polyaniline solid-contact electrodes based on 4′,4″(5″)-di-tert-butyldibenzo-18-crown-6-ether ionophore
    W. -S. Han
    Y. -H. Lee
    K. -J. Jung
    S. -Y. Ly
    T. -K. Hong
    M. -H. Kim
    Journal of Analytical Chemistry, 2008, 63 : 987 - 993
  • [27] Alternative coulometric signal readout based on a solid-contact ion-selective electrode for detection of nitrate
    Wang, Hemin
    Yuan, Baiqing
    Yin, Tanji
    Qin, Wei
    ANALYTICA CHIMICA ACTA, 2020, 1129 : 136 - 142
  • [28] Potassium ion-selective polyaniline solid-contact electrodes based on 4′,4"(5")-di-tert-butyldibenzo-18-crown-6-ether ionophore
    Han, W. -S.
    Lee, Y. -H.
    Jung, K. -J.
    Ly, S. -Y.
    Hong, T. -K.
    Kim, M. -H.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 63 (10) : 987 - 993
  • [29] Novel thallium(III) solid-contact ion-selective electrode with electropolymerized transducer
    Kharitonov, Sergey V.
    Zarembo, Yana V.
    Zarembo, Viktor I.
    ELECTROANALYSIS, 2006, 18 (13-14) : 1354 - 1362
  • [30] Stabilization of solid-contact sensors selective to surfactants
    Kulapin, A.I.
    Mikhajlova, A.M.
    Kulapina, E.G.
    Elektrokhimiya, 2003, 39 (05):