Spatially and Temporally Resolved Detection of Arsenic in a Capillary Dielectric Barrier Discharge by Hydride Generation High-Resolved Optical Emission Spectrometry

被引:36
|
作者
Burhenn, Sebastian [1 ]
Kratzer, Jan [2 ]
Svoboda, Milan [2 ]
Klute, Felix David [1 ]
Michels, Antje [1 ]
Veza, Damir [3 ]
Franzke, Joachim [1 ]
机构
[1] Leibniz Inst Analyt Wissensch ISAS eV, Bunsen Kirchhoff Str 11, D-44139 Dortmund, Germany
[2] Czech Acad Sci, Inst Analyt Chem, Veveri 97, Brno 60200, Czech Republic
[3] Univ Zagreb, Fac Sci, Dept Phys, Bijenicka 32, Zagreb 10000, Croatia
关键词
ATOMIC-ABSORPTION-SPECTROMETRY; FLUORESCENCE SPECTROMETRY; MASS-SPECTROMETRY; ION-SOURCE; RICE; SPECIATION; ANTIMONY; PLASMA; WATER; FISH;
D O I
10.1021/acs.analchem.7b05072
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method for arsenic detection by optical emission spectrometry (OES) is presented. Arsine (AsH3) is generated from liquid solutions by means of hydride generation (HG) and introduced into a capillary dielectric barrier discharge (DBD) where it is atomized and excited. A great challenge in OES is the reduction of the recorded background signal, because it negatively affects the limit of detection (LOD). In conventional DBD/OES methods, the signal intensity of the line of interest, in this case arsenic, is integrated over a long time scale. However, due to the pulsed character of the plasma, the plasma on-time is only a small fraction of the integration time. Therefore, a high amount of noise is added to the actual signal in each discharge cycle. To circumvent this, in the present study the emitted light from the DBD is collected by a fast gated iCCD camera, which is mounted on a modified monochromator. The experimental arrangement enables the recording of the emission signal of arsenic in the form of a monochromatic 2D-resolved picture. The temporal resolution of the iCCD camera in the nanosecond range provides the information at which point in time and how long arsenic is excited in the discharge. With use of this knowledge, it is possible to integrate only the arsenic emission by temporally isolating the signal from the background. With the presented method, the LOD for arsenic could be determined to 93 pg mL(-1) with a calibration curve linear over 4 orders of magnitude. As a consequence, the developed experimental approach has a potential for both mechanistic studies of arsine atomization and excitation in DBD plasmas as well as routine applications, in which arsenic determination at ultratrace levels is required.
引用
收藏
页码:3424 / 3429
页数:6
相关论文
共 50 条
  • [31] Elucidation of discharge mechanisms in He- and Ar-flexible μ-tube plasmas by temporally and spatially resolved plasma optical emission phoresis spectroscopy
    Song, Hao
    Tian, Caiyan
    Speicher, Luisa
    Ahlmann, Norman
    Brandt, Sebastian
    Niu, Guanghui
    Franzke, Joachim
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 219
  • [32] SPACE AND TIME RESOLVED OPTICAL EMISSION SPECTROSCOPY OF DIFFUSE COPLANAR BARRIER DISCHARGE IN NITROGEN
    Cech, Jan
    Stahel, Pavel
    Navratil, Zdenek
    Cernak, Mirko
    CHEMICKE LISTY, 2008, 102 : S1348 - S1351
  • [33] Dielectric barrier discharge-optical emission spectrometry for the simultaneous determination of halogens
    Zhang, Deng-Ji
    Cai, Yi
    Chen, Ming-Li
    Yu, Yong-Liang
    Wang, Jian-Hua
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (02) : 398 - 405
  • [34] Dielectric barrier discharge-optical emission spectrometry for the simultaneous determination of halogens
    Yu, Yong-Liang (yuyl@mail.neu.edu.cn), 1600, Royal Society of Chemistry (31):
  • [35] Determination of arsenic in biological samples by slurry sampling hydride generation atomic fluorescence spectrometry using in situ dielectric barrier discharge trap
    Liu, Meitong
    Liu, Tengpeng
    Liu, Jixin
    Mao, Xuefei
    Na, Xing
    Ding, Lan
    Chen, Guoying
    Qian, Yongzhong
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (03) : 526 - 534
  • [36] Miniaturized TOC analyzer using dielectric barrier discharge for catalytic oxidation vapor generation and point discharge optical emission spectrometry
    Li, Kai
    Chen, Hanjiao
    Chen, Zhiming
    He, Lin
    Hou, Xiandeng
    Jiang, Xiaoming
    ANALYTICA CHIMICA ACTA, 2021, 1172
  • [37] Metal Carbonyl Vapor Generation Coupled with Dielectric Barrier Discharge To Avoid Plasma Quench for Optical Emission Spectrometry
    Cai, Yi
    Li, Shao-Hua
    Dou, Shuai
    Yu, Yong-Liang
    Wang, Jian-Hua
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1366 - 1372
  • [38] Phase-resolved optical emission spectroscopy of a transient plasma created by a low-pressure dielectric barrier discharge jet
    Kaupe, J.
    Coenen, D.
    Mitic, S.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2018, 27 (10):
  • [39] Ultrasensitive Determination of Selenium and Arsenic by Modified Helium Atmospheric Pressure Glow Discharge Optical Emission Spectrometry Coupled with Hydride Generation
    Peng, Xiaoxu
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2019, 91 (15) : 10073 - 10080
  • [40] Evaluation of a new dielectric barrier discharge excitation source for the determination of arsenic with atomic emission spectrometry
    Zhu, Zhenli
    He, Haiyang
    He, Dong
    Zheng, Hongtao
    Zhang, Caixiang
    Hu, Shenghong
    TALANTA, 2014, 122 : 234 - 239