Analytical Method for Determination of Organochlorine Pesticides in Tea Brews using Single-Drop Microextraction with GC-ECD

被引:11
|
作者
Pakade, Yogesh B. [1 ]
Sharma, Ruchi [1 ]
Nadda, Gireesh [1 ]
Tewary, Dhananjay Kumar [1 ]
机构
[1] CSIR, Inst Himalayan Bioresource Technol, Palampur 176061, Himachal Prades, India
关键词
Single-drop microextraction; Gas chromatography; Organochlorine pesticides; Tea brew; SOLID-PHASE MICROEXTRACTION; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTRON-CAPTURE DETECTION; CAPILLARY GAS-CHROMATOGRAPHY; SOLVENT MICROEXTRACTION; WATER SAMPLES; ORGANOPHOSPHORUS PESTICIDES; EXTRACTION; VEGETABLES; RESIDUES;
D O I
10.1080/10942912.2011.565900
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
The single drop microextraction method was developed for the determination of ten organochlorine pesticides in tea brews using gas chromatograph-electron capture detector. The optimized parameters for effective extraction required a 2 L drop of n-hexane at the tip of a microsyringe immersed in 5 mL of a diluted tea brew sample for 25 min and stirred at 600 rpm. The limit of detection in the range of 0.01 to 0.025 g/L, with relative standard deviation of repeatability and reproducibility, was in the range of 110 and 824%. The relationship of the measured signal was a linear function (>0.9863) of concentration and the recovery method ranged from 92116%. The single drop microextraction method showed the advantage of being easy to operate, low consumption of organic solvent, and high extraction efficiency.
引用
收藏
页码:745 / 755
页数:11