Simultaneous determination of fluoxetine and norfluoxetine in dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

被引:18
|
作者
Cezimbra da Silva, Anne Caroline [1 ]
Raasch, Juliana Raquel [1 ]
Vargas, Tainara Gomes [1 ]
Peteffi, Giovana Piva [1 ]
Hahn, Roberta Zilles [1 ]
Antunes, Marina Venzon [1 ]
Perassolo, Magda Susana [1 ]
Linden, Rafael [1 ]
机构
[1] Univ Feevale, Inst Ciencias Saude, Lab Analyt Toxicol, Novo Hamburgo, RS, Brazil
关键词
Fluoxetine; Norfluoxetine; LC-MS/MS; Therapeutic monitoring; DBS; BIOANALYTICAL METHODS; LC-MS/MS; HEMATOCRIT; ENDOXIFEN; TAMOXIFEN;
D O I
10.1016/j.clinbiochem.2017.10.002
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Therapeutic drug monitoring (TDM) of the widely prescribed antidepressant fluoxetine (FLU) is recommended in certain situations, such as occurrence of toxicity, inadequate response or suspect of poor adherence. Dried blood spot (DBS) sampling is an increasingly studied alternative for TDM, particularly for outpatients, due to its ease of collection and inherent stability. Objectives: The aim of this study was to develop and validate an LC-MS/MS assay for the simultaneous quantification of FLU and norfluoxetine (NFLU) in DBS. Design and methods: The assay is based on a liquid extraction of single DBS with 8 mm of diameter, using FLU-D6 as the internal standard, followed by reversed phase separation in an Accucore (R) C18 column (100 x 2.1 mm, 2.6 mu m). Mobile phase was composed of water and acetonitrile (gradient from 80: 20 to 50: 50, v/v), both containing formic acid 0.1%. The assay was validated and applied to 30 patients under FLU pharmacotherapy. Results: The assay was linear in the range 10-750 ng mL(-1). Precision assays presented CV% of 3.13-9.61 and 3.54-7.99 for FLU and NFLU, respectively, and accuracy in the range of 97.98-110.44% and 100.25-105.8%. FLU and NFLU were stable at 25 and 45 degrees C for 7 days. The assay was evaluated in 30 patients under FLU treatment. Concentrations of both compounds were higher in DBS than in plasma, and the use of the multiplying factors 0.71 and 0.68 for FLU and NFLU, respectively, allowed acceptable estimation of plasma concentrations, with median prediction bias of -0.55 to 0.55% and mean differences of 0.4 to 2.2 ng mL(-1). Conclusions: The presented data support the clinical use of DBS for therapeutic drug monitoring of FLU.
引用
收藏
页码:85 / 93
页数:9
相关论文
共 50 条
  • [41] Simultaneous Determination of Ergot Alkaloids in Swine and Dairy Feeds Using Ultra High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Poapolathep, Saranya
    Klangkaew, Narumol
    Zhang, Zhaowei
    Giorgi, Mario
    Logrieco, Antonio Francesco
    Poapolathep, Amnart
    [J]. TOXINS, 2021, 13 (10)
  • [42] On-line liquid chromatography/tandem mass spectrometry simultaneous determination of opiates, cocainics and amphetamines in dried blood spots
    Saussereau, E.
    Lacroix, C.
    Gaulier, J. M.
    Goulle, J. P.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 885 : 1 - 7
  • [43] Determination of Phenoxy Acid Herbicides in Cereals Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Guo, Tao
    Wang, Xiaoli
    Wang, Haifeng
    Hu, Yufen
    Zhang, Shiyong
    Zhao, Rusong
    [J]. JOURNAL OF FOOD PROTECTION, 2019, 82 (07) : 1160 - 1165
  • [44] Determination of succinylacetone in dried blood spots and liquid urine as a dansylhydrazone by liquid chromatography tandem mass spectrometry
    Al-Dirbashi, OY
    Rashed, MS
    Ten Brink, HJ
    Jakobs, C
    Filimban, N
    Al-Ahaidib, LY
    Jacob, M
    Al-Sayed, MM
    Al-Hassnan, Z
    Faqeih, E
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 831 (1-2): : 274 - 280
  • [45] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    Rodin, I. A.
    Stavrianidi, A. N.
    Braun, A. V.
    Shpigun, O. A.
    Berizovskaya, E. I.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (13) : 1252 - 1258
  • [46] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    I. A. Rodin
    A. N. Stavrianidi
    A. V. Braun
    O. A. Shpigun
    E. I. Berizovskaya
    [J]. Journal of Analytical Chemistry, 2014, 69 : 1252 - 1258
  • [47] Determination of 17α-methyltestosterone in aquatic products using high-performance liquid chromatography-tandem mass spectrometry
    Zhang, Xuan
    Fang, Changling
    Lou, Xiaoyi
    Yang, Guangxin
    Kong, Cong
    Shi, Yongfu
    Huang, Dongmei
    [J]. MICROCHEMICAL JOURNAL, 2022, 183
  • [48] Determination of Dapsone in Muscle Tissue and Milk Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Kaklamanos, George
    Theodoridis, Georgios
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (01) : 29 - 35
  • [49] Liquid chromatography-tandem mass spectrometry method for simultaneous quantification of bisoprolol, ramiprilat, propranolol and midazolam in rat dried blood spots
    Trobec, Katja Cyan
    Trontelj, Jurij
    Springer, Jochen
    Lainscak, Mitja
    Kos, Mojca Kerec
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 958 : 29 - 35
  • [50] Simultaneous determination of 19 quinolone residues in honey using high performance liquid chromatography-tandem mass spectrometry
    Ding Tao
    Shen Dongxu
    Xu Jinzhong
    Wu Bin
    Chen Huilan
    Shen Chongyu
    Shen Weijian
    Zhao Zengyun
    Lian Hongzhen
    [J]. CHINESE JOURNAL OF CHROMATOGRAPHY, 2009, 27 (01) : 34 - 38