Test-retest variability of static perimetry and microperimetry results from the RUSH2A study

被引:0
|
作者
Ayala, Allison [1 ]
Liang, Wendi [1 ]
Birch, David G. [2 ]
Cheetham, Janet K. [3 ]
Chegarnov, Elvira N. [4 ]
Duncan, Jacque L. [5 ]
Durham, Todd [3 ]
Ferris, Frederick L. [6 ]
Lad, Eleonora M. [7 ]
Maguire, Maureen [8 ]
Pennesi, Mark E. [4 ]
机构
[1] Jaeb Ctr Hlth Res, Tampa, FL USA
[2] Retina Fdn Southwest, Dallas, TX USA
[3] Fdn Fighting Blindness, Columbia, MD USA
[4] Oregon Hlth & Sci Univ, Casey Eye Inst, Portland, OR 97201 USA
[5] Univ Calif San Francisco, Ophthalmol, San Francisco, CA 94143 USA
[6] Ophthalm Res Consultants, Waxhaw, NC USA
[7] Duke Univ, Med Ctr, Ophthalmol, Durham, NC USA
[8] Univ Penn, Philadelphia, PA 19104 USA
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
3342
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Test-retest variability of frequency-doubling perimetry and conventional perimetry in glaucoma patients and normal subjects
    Chauhan, BC
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (03) : 648 - 656
  • [22] Test-retest variability of mean sensitivity and volume sensitivity on microperimetry in patients with retinitis pigmentosa
    Karuntu, Jessica Serena
    Xuan-Thanh-An Nguyen
    Jolly, Jasleen K.
    Boon, Camiel J. F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [23] Test-retest variability for standard automated perimetry and short-wavelength automated perimetry in diabetic patients
    Bengtsson, Boel
    Hellgren, Karl-Johan
    Agardh, Elisabet
    ACTA OPHTHALMOLOGICA, 2008, 86 (02) : 170 - 176
  • [24] Test-retest variability of mesopic microperimetry-associated parameters in patients with retinitis pigmentosa: REPEAT Study Report No. 2
    Karuntu, Jessica S.
    Pfau, Maximilian
    Jolly, Jasleen K.
    Boon, Camiel J. F.
    ACTA OPHTHALMOLOGICA, 2024,
  • [25] Static Perimetry in the Rate of Progression in USH2A- related Retinal Degeneration (RUSH2A) Study: Assessment Through 2 Years
    Duncan, Jacque L.
    Cheng, Peiyao
    Maguire, Maureen G.
    Ayala, Allison A.
    Birch, David G.
    Cheetham, Janet K.
    Durham, Todd A.
    Fahim, Abigail T.
    Hoyng, Carel B.
    Ishikawa, Hiroshi
    Michaelides, Michel
    Pennesi, Mark E.
    Sahel, Jose-Alain
    Stingl, Katarina
    Weng, Christina Y.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2023, 250 : 103 - 110
  • [26] Test-Retest Variability of Microperimetry Using the Nidek MP1 in Patients with Macular Disease
    Chen, Fred K.
    Patel, Praveen J.
    Xing, Wen
    Bunce, Catey
    Egan, Catherine
    Tufail, Adnan T.
    Coffey, Peter J.
    Rubin, Gary S.
    Da Cruz, Lyndon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (07) : 3464 - 3472
  • [27] Test-retest variability of multifocal visual evoked potential and SITA standard perimetry in glaucoma
    Bjerre, A
    Grigg, JR
    Parry, NRA
    Henson, DB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (11) : 4035 - 4040
  • [28] Test-retest variability of blue-on-yellow perimetry is greater than white-on-white perimetry in normal subjects
    Kwon, YH
    Park, HJ
    Jap, A
    Ugurlu, S
    Caprioli, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (01) : 29 - 36
  • [29] Test-Retest Variability of Fundus-Tracked Perimetry at the Peripapillary Region in Open Angle Glaucoma
    Wu, Zhichao
    McKendrick, Allison M.
    Hadoux, Xavier
    Gaskin, Jennifer C. Fan
    Ang, Ghee Soon
    Sarossy, Marc G.
    Crowston, Jonathan G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (08) : 3619 - 3625
  • [30] Comparing test-retest variability of Compass perimetry with the Humphrey Field Analyzer at the edges of glaucomatous scotomas
    Eugenie, Juleke
    Majoor, Anne
    Vermeer, Koenraad Arndt
    Lemij, Hans G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2021, 62 (08)