Design of ITER divertor VUV spectrometer and prototype test at KSTAR tokamak

被引:9
|
作者
Seon, Changrae [1 ]
Hong, Joohwan [2 ]
Song, Inwoo [2 ]
Jang, Juhyeok [2 ]
Lee, Hyeonyong [2 ]
An, Younghwa [1 ]
Kim, Bosung [3 ]
Jeon, Taemin [2 ]
Park, Jaesun [2 ]
Choe, Wonho [2 ]
Lee, Hyeongon [1 ]
Pak, Sunil [1 ]
Cheon, MunSeong [1 ]
Choi, Jihyeon [1 ]
Kim, Hyeonseok [1 ]
Biel, Wolfgang [4 ]
Bernascolle, Philippe [5 ]
Barnsley, Robin [5 ]
O'Mullane, Martin [6 ]
机构
[1] Natl Fus Res Inst, Gwahangno 169-148, Daejeon, South Korea
[2] Korea Adv Inst Sci & Technol, Daehak Ro,291, Daejeon, South Korea
[3] Ajou Univ, Dept Energy Syst Res, Suwon 443749, South Korea
[4] Forschungszentrum Julich, EURATOM Assoc, Trilateral Euregio Cluster, Inst Plasmaphys, D-52425 Julich, Germany
[5] ITER Org, Route Vinon Sur Verdon CS 90 046, St Paul Les Durance, France
[6] Univ Strathclyde, Dept Phys SUPA, Glasgow G4 ONG, Lanark, Scotland
来源
EUROPEAN PHYSICAL JOURNAL D | 2017年 / 71卷 / 12期
基金
新加坡国家研究基金会;
关键词
VACUUM-ULTRAVIOLET; X-RAY; SPECTROSCOPY; RESOLUTION; DETECTOR; RANGE;
D O I
10.1140/epjd/e2017-70825-3
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Design and development of the ITER divertor VUV spectrometer have been performed from the year 1998, and it is planned to be installed in the year 2027. Currently, the design of the ITER divertor VUV spectrometer is in the phase of detail design. It is optimized for monitoring of chord-integrated VUV signals from divertor plasmas, chosen to contain representative lines emission from the tungsten as the divertor material, and other impurities. Impurity emission from overall divertor plasmas is collimated through the relay optics onto the entrance slit of a VUV spectrometer with working wavelength range of 14.6-32 nm. To validate the design of the ITER divertor VUV spectrometer, two sets of VUV spectrometers have been developed and tested at KSTAR tokamak. One set of spectrometer without the field mirror employs a survey spectrometer with the wavelength ranging from 14.6nm to 32nm, and it provides the same optical specification as the spectrometer part of the ITER divertor VUV spectrometer system. The other spectrometer with the wavelength range of 5-25nm consists of a commercial spectrometer with a concave grating, and the relay mirrors with the same geometry as the relay mirrors of the ITER divertor VUV spectrometer. From test of these prototypes, alignment method using backward laser illumination could be verified. To validate the feasibility of tungsten emission measurement, furthermore, the tungsten powder was injected in KSTAR plasmas, and the preliminary result could be obtained successfully with regard to the evaluation of photon throughput.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] THE STATUS OF ITER DIVERTOR DESIGN CONCEPTS
    COHEN, SA
    WERLEY, KA
    HARRISON, MFA
    PISTUNOVITCH, V
    KUKUSHKIN, A
    KRASHENNINIKOV, S
    SUGIHARA, M
    PERKINS, LJ
    BULMER, R
    POST, DE
    WESLEY, J
    JOURNAL OF NUCLEAR MATERIALS, 1992, 196 : 50 - 58
  • [42] Conceptual Design of Tungsten Monoblock Components for KSTAR Divertor
    Song, J. H.
    Kim, K. M.
    Im, K.
    Hong, S. H.
    Kim, H. T.
    Kim, H. K.
    Park, S. H.
    Kim, B. C.
    Yang, H. L.
    Kim, Y. S.
    2015 IEEE 26TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2015,
  • [43] Divertor design and its integration into ITER
    Janeschitz, G
    Antipenkov, A
    Federici, G
    Ibbott, C
    Kukushkin, A
    Ladd, P
    Martin, E
    Tivey, R
    NUCLEAR FUSION, 2002, 42 (01) : 14 - 20
  • [44] Status of ITER divertor design concepts
    Cohen, S.A.
    Werley, K.A.
    Harrison, M.F.A.
    Pistunovitch, V.
    Kukushkin, A.
    Krashenninikov, S.
    Sugihara, M.
    Perkins, L.J.
    Bulmer, R.
    Post, D.E.
    Wesley, J.
    ITER Team
    Journal of Nuclear Materials, 1992, 196-98 : 50 - 58
  • [45] Ultrasonic studies on ITER divertor and first wall prototype modules
    Pitkänen, J
    Kauppinen, P
    Jeskanen, H
    Tähtinen, S
    Sandlin, S
    FUSION ENGINEERING AND DESIGN, 2003, 66-68 : 359 - 364
  • [46] Development of a full-size divertor cassette prototype for ITER
    Ulrickson, MA
    Vieider, G
    Pacher, HD
    Smid, I
    Wu, C
    Pizzuto, A
    Riccardi, B
    Roccella, M
    Chappuis, P
    Lemarois, G
    Schlosser, J
    Rödig, M
    Plöchl, L
    Akiba, M
    Mazul, I
    Tivey, R
    FUSION ENERGY 1996, VOL 2, 1997, : 809 - 816
  • [47] ITER prototype divertor cassette fabrication, integration and final assembly
    Driemeyer, DE
    Wille, GW
    Cole, FR
    Ayres, HD
    Zeiders, R
    Chatterton, WJ
    Foreman, K
    18TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, 1999, : 109 - 114
  • [48] Results of acoustic monitoring of ITER divertor vertical target prototype
    Courtois, X.
    Escourbiac, F.
    Kuznetsov, V.
    Riccardi, B.
    Merola, M.
    FUSION ENGINEERING AND DESIGN, 2010, 85 (7-9) : 1391 - 1395
  • [49] ITER-like divertor target for DEMO: Design study and fabrication test
    Crescenzi, F.
    Greuner, H.
    Roccella, S.
    Visca, E.
    You, J. H.
    FUSION ENGINEERING AND DESIGN, 2017, 124 : 432 - 436
  • [50] DESIGN METHOD OF DIVERTOR IN TOKAMAK REACTORS
    UEDA, N
    ITOH, SI
    TANAKA, M
    ITOH, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1991, 28 (03) : 187 - 198