The water wall tubes run on a hazardous environment, and the fire, gas and coil ash often attack the tube and corrosion, erosion and fatigue cause to the tube wall thickness decrease and being failure, even lead to explosion and leakage, by which the safety and cost-effective of the thermal power plant is influenced seriously. The explosion and leakage of boiler tubes in power plant is a serious problem that often leads to unscheduled and costly outages. According to the defect characteristics and running condition of boiler water wall tube, this paper introduces the development of the hot corrosion problem, research on the performance of new-type protective coating on water-wall tubes for thermal power plant, inspection method of nondestructive testing (NDT) remote inspection tool to provide inspection for complex water wall tube configurations and boiler water wall tube inspection methods automatically.
引用
收藏
页码:2415 / 2420
页数:6
相关论文
共 50 条
  • [21] Failure analysis on tube socket crack of supercritical boiler water wall header
    Zheng, Xiangfeng
    Jiang, Yunjian
    Feng, Yanting
    Wang, Qing
    Niu, Xiaoguang
    Hao, XiaoJun
    Li, Wenbin
    Li, Zhongwei
    Xu, Xuexia
    Li, Wenpeng
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 4616 - 4619
  • [22] Investigation on the welding-induced multiple failures in boiler water wall tube
    Liu, Kexiu
    Feng, Xiaoliang
    Ma, Kuo
    Wang, Lian
    Xie, Xiaowu
    Lu, Zhongming
    ENGINEERING FAILURE ANALYSIS, 2021, 121
  • [23] Analysis of spiral water-wall tube in once-through boiler
    Hsi An Chiao Tung Ta Hsueh, 11 (51-54):
  • [24] INCREASING RELIABILITY OF ULTRASONIC INSPECTION OF BOILER TUBE JOINTS
    RAIKHMAN, AZ
    CHISTYAK.SN
    WELDING PRODUCTION, 1969, 16 (07): : 66 - &
  • [25] Cause Analysis on Wall Thickness Reduction of Fire Side of Water Wall Tube of Power Plant Boiler
    Guo, Linyuan
    Chen, Dongming
    Chen, Shouliang
    Jin, Dong
    Dai, Qiang
    Pan, Qingchuan
    2022 9TH INTERNATIONAL FORUM ON ELECTRICAL ENGINEERING AND AUTOMATION, IFEEA, 2022, : 1027 - 1031
  • [26] TEMPERATURES AND STRESSES IN A BOILER MEMBRANE WALL TUBE
    DIPASQUANTONIO, F
    NUCLEAR ENGINEERING AND DESIGN, 1974, 31 (02) : 280 - 293
  • [27] Development of remaining wall thickness measurement system for boiler wall tube using gamma scattering technique
    Durongsak, K.
    Yenjai, C.
    Rassame, S.
    INTERNATIONAL NUCLEAR SCIENCE AND TECHNOLOGY CONFERENCE 2016, 2017, 860
  • [28] ULTRASONIC INSPECTION OF THICK WALL TUBE
    SHIRAIWA, T
    YAMAGUCH.H
    ONO, M
    SUMITOMO SEARCH, 1969, (02): : 114 - &
  • [29] Circulating Fluidized Bed Boiler Water-Wall Tube Abrasion Integrity Assessment
    Lee, Sang-yeom
    Hyun, Jung-seob
    Myung, Joo-hong
    Son, Jong-duk
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2023, 47 (02) : 107 - 115
  • [30] Failure investigation of a water-wall tube of fossil-fuel fired boiler
    Ranjeeth, R.
    Aditya, D.
    Gautam, Anil
    Singh, S. P.
    Bhattacharya, S.
    ENGINEERING FAILURE ANALYSIS, 2024, 155