Performance of Porous Tantalum vs. Titanium Cup in Total Hip Arthroplasty: Randomized Trial with Minimum 10-Year Follow-Up

被引:71
|
作者
Wegrzyn, Julien [1 ]
Kaufman, Kenton R. [1 ]
Hanssen, Arlen D. [1 ]
Lewallen, David G. [1 ]
机构
[1] Mayo Clin, Dept Orthoped Surg, Rochester, MN 55905 USA
来源
JOURNAL OF ARTHROPLASTY | 2015年 / 30卷 / 06期
关键词
total hip arthroplasty; porous tantalum monoblock cup; cementless fixation; osseointegration; aseptic loosening; MONOBLOCK ACETABULAR COMPONENT; BONE INGROWTH; COMPUTED-TOMOGRAPHY; POLYETHYLENE WEAR; OSTEOLYSIS; REPLACEMENTS; MULTICENTER; DISLOCATION; INTERFACE; 5-YEAR;
D O I
10.1016/j.arth.2015.01.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Porous tantalum monoblock cups have been proposed to improve survivorship of cementless primary THA. However, there are few direct comparative trials to established implants such as porous-coated titanium cups. 113 patients were randomized into two groups according to the cup: a porous tantalum monoblock cup (TM) or a porous-coated titanium monoblock cup (control). At a mean of 12 years after THA, no implants migrated in both groups. Two TM patients (4%) and 13 control patients (33%) presented with radiolucency around the cup (P > 0.001). In the control group, 1 cup (2%) was revised for aseptic loosening. At 12 years post-implantation, porous tantalum monoblock cups demonstrated 100% survivorship, and significantly less radiolucency as compared to porous-coated titanium monoblock cups. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1008 / 1013
页数:6
相关论文
共 50 条
  • [21] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Sakai, Takashi
    Ohzono, Kenji
    Nishii, Takashi
    Takao, Masaki
    Miki, Hidenobu
    Nakamura, Nobuo
    Sugano, Nobuhiko
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (04) : 605 - 610
  • [22] The Bi-Surface total knee arthroplasty: Minimum 10-year follow-up study
    Nakamura, Shinichiro
    Kobayashi, Masahiko
    Ito, Hiromu
    Nakamura, Kenji
    Ueo, Toyoji
    Nakamura, Takashi
    KNEE, 2010, 17 (04): : 274 - 278
  • [23] Modular acetabular reconstructive cup in acetabular revision total hip arthroplasty at a minimum ten year follow-up
    Takashi Sakai
    Kenji Ohzono
    Takashi Nishii
    Masaki Takao
    Hidenobu Miki
    Nobuo Nakamura
    Nobuhiko Sugano
    International Orthopaedics, 2013, 37 : 605 - 610
  • [24] Hybrid Component Fixation in Total Knee Arthroplasty Minimum of 10-Year Follow-Up Study
    Yang, Jae-Hyuk
    Yoon, Jung-Ro
    Oh, Chi-Hun
    Kim, Taik-Sun
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06): : 1111 - 1118
  • [26] Patient expectation fulfilment following total hip arthroplasty: a 10-year follow-up study
    Liam Z. Yapp
    Nicholas D. Clement
    Deborah J. Macdonald
    Colin R. Howie
    Chloe E. H. Scott
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 963 - 971
  • [27] Patient expectation fulfilment following total hip arthroplasty: a 10-year follow-up study
    Yapp, Liam Z.
    Clement, Nicholas D.
    Macdonald, Deborah J.
    Howie, Colin R.
    Scott, Chloe E. H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (07) : 963 - 971
  • [28] Porous Tantalum Patellar Components in Revision Total Knee Arthroplasty Minimum 5-Year Follow-Up
    Kamath, Atul F.
    Gee, Albert O.
    Nelson, Charles L.
    Garino, Jonathan P.
    Lotke, Paul A.
    Lee, Gwo-Chin
    JOURNAL OF ARTHROPLASTY, 2012, 27 (01): : 82 - 87
  • [29] Total Hip Arthroplasty Using Cementless Grit-Blasted Femoral Component A Minimum 10-Year Follow-Up Study
    Hwang, Kyu-Tae
    Kim, Young-Ho
    Kim, Yee-Suk
    Choi, Il-Yong
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08): : 1554 - 1561
  • [30] Clinical Survivorship of Aseptic Revision Total Knee Arthroplasty Using Hinged Knees and Tantalum Cones at Minimum 10-Year Follow-Up
    Abdelaziz, Hussein
    Jaramillo, Rodrigo
    Gehrke, Thorsten
    Ohlmeier, Matte
    Citak, Mustafa
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12): : 3018 - 3022