Heat Transfer Model and Analysis of Oil-immersed Electrical Transformers with Heat Pipe Radiator

被引:0
|
作者
Li, Guanghua [1 ]
Liu, Honglei [1 ]
Wang, Dejian [1 ]
机构
[1] State Grid China Technol Coll, Tai An, Shandong, Peoples R China
来源
关键词
oil-immersed transformer; heat pipe; cooling; heat transfer model;
D O I
10.4028/www.scientific.net/AMR.516-517.312
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper has formulated a heat transfer model for analyzing the cooling properties of a heat pipe cooling device of oil-immersed electrical transformer. Based on the model, the oil temperature field of a 30 KVA oil-immersed transformer has been numerical simulated, and experiments also had been conducted. Results showed that the numerical simulation has good agreement with experiment results. Results also showed that heat pipe radiator is feasible for oil-immersed electrical transformer cooling. The model can be used to analyze the oil temperature distribution properties in an oil-immersed electrical transformer with heat pipe cooling device, and provide theoretical guide for transformer design and improvement.
引用
收藏
页码:312 / 315
页数:4
相关论文
共 50 条
  • [41] Investigation of Electrostatic Charging Mechanism in Aged Oil-immersed Transformers
    Okabe, Shigemitsu
    Kohtoh, Masanori
    Amimoto, Tsuyoshi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (01) : 287 - 293
  • [42] Thermal analysis of an innovative flat heat pipe radiator
    寇志海
    白敏丽
    杨洪武
    JournalofCentralSouthUniversityofTechnology, 2011, 18 (02) : 568 - 572
  • [43] MULTIPURPOSE HEAT PIPE RADIATOR DESIGN AND ANALYSIS CODE
    HAINLEY, DC
    HEAT TRANSFER - PHILADELPHIA, 1989, 1989, 85 : 235 - 240
  • [44] Thermal analysis of an innovative flat heat pipe radiator
    Kou Zhi-hai
    Ba Min-li
    Yang Hong-wu
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (02): : 568 - 572
  • [45] Thermal analysis of an innovative flat heat pipe radiator
    Zhi-hai Kou
    Min-li Bai
    Hong-wu Yang
    Journal of Central South University, 2011, 18 : 568 - 572
  • [46] Model for Heat Pipe Position Optimization of Transformers Cooled by Heat Pipes
    Zhang, Xi
    Yang, Junbao
    Deng, Min
    RENEWABLE AND SUSTAINABLE ENERGY, PTS 1-7, 2012, 347-353 : 3765 - +
  • [47] Recent diagnostic technology on oil-immersed power transformers in Japan
    1600, IEEE Power Engineering Society, IEEE Japan (Institute of Electrical and Electronics Engineers Inc.):
  • [48] Evaluation of the Cooling System Calculation Technique for Oil-Immersed Transformers
    Dmitrieva, O. S.
    Patrakova, G. R.
    Dmitriev, A., V
    2017 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING, APPLICATIONS AND MANUFACTURING (ICIEAM), 2017,
  • [49] SHORT-TIME LOADING OF OIL-IMMERSED TRANSFORMERS.
    de Kuijper, C.E.M.
    Elektrotechniek, 1984, 62 (09): : 757 - 769
  • [50] Testing of the oil-immersed sensible heat storage unit with circular channel solid heat body under charging modes with different heat transfer temperature difference
    Cheng, Fangzheng
    Zou, Yang
    Huang, Shengyao
    Wang, Xinyi
    Yu, Xinfeng
    Ma, Weiwei
    Zhou, Hao
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2022, 46 (15) : 24487 - 24500