Diagnostic Accuracy of Point-of-care Tests Used to Detect Arterial Disease in Diabetes TEsting for Arterial Disease in Diabetes (TrEAD) Study

被引:17
|
作者
Normahani, Pasha [1 ,2 ]
Poushpas, Sepideh [1 ]
Alaa, Mays [1 ]
Bravis, Vassiliki [3 ,4 ]
Sounderajah, Viknesh [1 ]
Aslam, Mohammed [1 ,2 ]
Jaffer, Usman [1 ,2 ]
机构
[1] Imperial Coll NHS Healthcare Trust, Imperial Vasc Unit, London, England
[2] Imperial Coll London, Dept Surg & Canc, London, England
[3] Imperial Coll NHS Healthcare Trust, Diabet Foot Unit, London, England
[4] Imperial Coll London, Diabet Endocrinol & Metab Med, Fac Med, London, England
关键词
diabetes; diabetic foot; diagnosis; duplex ultrasound; foot ulcer; peripheral arterial disease; point-of-care testing; point-of care ultrasound; FOOT ULCERS; ULTRASOUND; AMPUTATION; PRESSURE; PEOPLE; INDEX; RISK;
D O I
10.1097/SLA.0000000000004545
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: We compared the diagnostic performance of a novel point-of-care duplex ultrasound test (podiatry ankle duplex scan; PAD-scan) against commonly used bedside tests for the detection of PAD in diabetes. Background: PAD is a major risk factor for diabetic foot ulceration and amputation. Its diagnosis is fundamental though challenging. Although a variety of bedside tests are available, there is no agreement as to which is the most useful. PAD-scan may be advantageous over current tests as it allows for vessel visualization and more accurate arterial waveform assessment. However, its accuracy has not been previously evaluated. Methods: From March to October 2019, we recruited 305 patients from 2 diabetic foot clinics. The diagnostic performance of ankle-brachial pressure index, toe-brachial pressure index, transcutaneous pressure of oxygen, pulse palpation, and ankle waveform assessment using PAD-scan and Doppler devices (audible and visual waveform assessment) were assessed. The reference test was a full lower limb duplex ultrasound. Results: Based on the reference test, 202 (66.2%) patients had evidence of PAD. PAD-scan had a significantly higher sensitivity [95%, confidence interval (CI) 90%-97%) as compared to all other tests. Particularly low sensitivities were seen with pulse palpation (43%, CI 36%-50%) and transcutaneous pressure of oxygen (31%, CI 24%-38%). PAD-scan had a lower specificity (77%, CI 67%-84%) compared to toe-brachial pressure index (86%, CI 78%-93%; P < 0.001), but not statistically different when compared to all other tests. Conclusions: PAD-scan has superior diagnostic utility and is a valid first line investigation.
引用
收藏
页码:E605 / E612
页数:8
相关论文
共 50 条
  • [1] Study protocol for a comparative diagnostic accuracy study of bedside tests used to detect arterial disease in diabetes: TEsting for Arterial disease in Diabetes (TrEAD) study
    Normahani, Pasha
    Poushpas, Sepideh
    Alaa, Mays
    Bravis, Vassiliki
    Aslam, Mohammed
    Jaffer, Usman
    BMJ OPEN, 2020, 10 (02):
  • [2] Point-of-care diagnostic tests for tuberculosis disease
    Hong, Jia Mei
    Lee, Hyeyoung
    Menon, Nishanth, V
    Lim, Chwee Teck
    Lee, Luke P.
    Ong, Catherine W. M.
    SCIENCE TRANSLATIONAL MEDICINE, 2022, 14 (639)
  • [3] Point-of-Care Testing in Diabetes Care
    Matteucci, E.
    Giampietro, O.
    MINI-REVIEWS IN MEDICINAL CHEMISTRY, 2011, 11 (02) : 178 - 184
  • [4] Diabetes care for patients with peripheral arterial disease
    Heikkinen, M.
    Salmenpera, M.
    Lepantalo, A.
    Lepantalo, M.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2007, 33 (05) : 583 - 591
  • [5] Peripheral arterial disease and diabetes foot care
    Sum, C. F.
    Lim, S. C.
    Tavintharan, S.
    SINGAPORE MEDICAL JOURNAL, 2008, 49 (02) : 93 - 94
  • [6] Point of care device for diagnosing and treatment of diabetes related peripheral arterial disease
    Srivishnuprasath, K.
    Karthik, Varshini
    Kumar, D. Ashok
    3RD INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2020), PTS 1-6, 2020, 912
  • [7] Use of ABI to detect peripheral arterial disease in diabetes - A recommendation for primary care physicians
    Mishra, Nibedita
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2021, 10 (01) : 154 - 157
  • [8] Diagnostic accuracy of the maximal systolic acceleration to detect peripheral arterial disease
    Willems, Siem A.
    Dolfing, Saskia G.
    van Wissen, Rob C.
    van der Vorst, Joost R.
    van Schaik, Jan
    Schepers, Abbey
    Hamming, Jaap F.
    Brouwers, Jeroen J. W. M.
    JOURNAL OF VASCULAR SURGERY, 2024, 79 (02) : 405 - 411
  • [9] Point-of-care testing in diabetes mellitus
    Price, CP
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2003, 41 (09) : 1213 - 1219
  • [10] Point-of-care testing in diabetes management
    Cozma, Angela
    Vonica, Camelia
    Sitar-Taut, Adela
    Fodor, Adriana
    REVISTA ROMANA DE MEDICINA DE LABORATOR, 2019, 27 (02): : 125 - 135