Digital mammography in direct magnification technique using a large-area amorphous silicon X-ray detector.

被引:15
|
作者
Hermann, KP
Hundertmark, C
Funke, M
von Brenndorff, A
Grabbe, E
机构
[1] Univ Gottingen, Inst Med Phys & Biophys, D-37073 Gottingen, Germany
[2] Univ Gottingen, Zentrum Radiol, Abt Rontgendiagnost 1, D-3400 Gottingen, Germany
[3] Feinfocus Med Technik GmbH, Garbsen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 1999年 / 170卷 / 05期
关键词
digital mammography; flat panel X-ray detector; direct magnification technique; contrast-detail resolution;
D O I
10.1055/s-2007-1011080
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the image quality of a new direct digital mammography system using a large-area amorphous silicon Xray detector in a phantom study. Materials and Methods: The contrast-detail resolution as a function of the tube voltages, the magnification factors and the mean glandular doses were investigated using dedicated test objects. Results: The contrast-detail resolution was significantly improved in comparison with conventional screen-film mammography. Usually, the doses necessary to obtain these high-quality survey mammograms were smaller. Conclusions: By combining the direct magnification technique and a digital flat panel detector the limited spatial resolution of such image receptors can be overcome. With this direct digital mammography technique, a digital image was directly captured without an intermediate step of optical or mechanical scan.
引用
收藏
页码:503 / 506
页数:4
相关论文
共 50 条
  • [41] Application of X-ray crystallographic detector to whole breast digital mammography
    Xie, JH
    Williams, MB
    Stanton, M
    Rosen, D
    Phillips, W
    Fajardo, LL
    DIGITAL MAMMOGRAPHY '96, 1996, 1119 : 139 - 144
  • [42] Large-area amorphous silicon TFT-based x-ray image sensors for medical imaging and non destructive testing
    Weisfield, RL
    PROCEEDINGS OF THE FOURTH SYMPOSIUM ON THIN FILM TRANSISTOR TECHNOLOGIES, 1999, 98 (22): : 369 - 380
  • [43] X-ray imaging with amorphous selenium: Optimal spectra for digital mammography
    Fahrig, R
    Rowlands, JA
    Yaffe, MJ
    MEDICAL PHYSICS, 1996, 23 (04) : 557 - 567
  • [44] A large area MCP detector for X-ray imaging
    Lees, JE
    Pearson, JF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3): : 410 - 424
  • [45] Digital X-ray microscopy with a microfocal X-ray generation and an MWPC area detector
    Bateman, J.E.
    Moss, G.R.
    Rockett, P.
    Webb, S.
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 767 - 772
  • [46] DIGITAL X-RAY MICROSCOPY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    MOSS, GR
    ROCKETT, P
    WEBB, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 767 - 772
  • [47] Large-area x-ray topographs of lattice undulation of bonded silicon-on-insulator wafers
    Fukuda, K., 1600, Japan Society of Applied Physics (42):
  • [48] Edgeless silicon sensors for Medipix-based large-area X-ray imaging detectors
    Bosma, M. J.
    Visser, J.
    Evrard, O.
    De Moor, P.
    De Munck, K.
    Tezcan, D. Sabuncuoglu
    Koffeman, E. N.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [49] Large-area X-ray topographs of lattice undulation of bonded silicon-on-insulator wafers
    Fukuda, K
    Yoshida, T
    Shimura, T
    Yasutake, K
    Umeno, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2003, 42 (2A): : L117 - L119
  • [50] Optically Seamless Flexible Electronic Tiles for Ultra Large-Area Digital X-Ray Imaging
    Smith, Joseph T.
    Couture, Aaron J.
    Stowell, John R.
    Allee, David R.
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2014, 4 (06): : 1109 - 1115