Analysis of Dynamic Behavior of V-Shaped Atomic Force Microscope Cantilever in Contact and Tapping Modes by Considering Various Immersion Surroundings

被引:1
|
作者
Pasha, Ali Hossein Gholizadeh [1 ]
Sadeghi, Ali [1 ]
机构
[1] Islamic Azad Univ, Damavand Branch, Renewable Energy Res Ctr, Damavand, Iran
关键词
Atomic force microscope; V-shaped beam; Various surroundings; Finite element method; Frequency response function; VIBRATION MODES; BEAM; SENSITIVITY;
D O I
10.1007/s13369-020-04660-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In atomic force microscope (AFM) as a powerful device for scanning the samples, a cantilever is used to sense the variations of its dynamic characteristics due to the tip-sample interaction. Theoretical models that can accurately simulate the surface-coupled dynamics of the cantilever are necessary for quantifiable and qualitative explanation and understanding of measured results. A good understanding of the dynamics of AFM cantilevers vibrating in liquid is needed for the interpretation of scanning images, selection of AFM operating conditions and evaluation of sample's mechanical properties. In this paper, the amplitude of frequency response functions (FRF) of vertical and rotational movements for a V-shaped atomic force microscope beam immersed in various surroundings has been surveyed for the first time. For rising the precision of theoretical model, we have considered all needful details for the beam and sample. The amplitude of FRF of vertical and rotational movements and resonant frequency of beam have been surveyed by supposing cantilever thickness, breadth and length, the angle between cantilever and sample surface, tip height and normal and lateral tip-sample interaction force. In this study, carbon tetrachloride (CCL4), methanol, acetone, water and air have been considered as surroundings. The results show that an increase in the tip-sample interaction force considerably raises the amount of resonant frequency. By increasing the liquid viscosity, the amplitude of FRF for vertical and rotational movements and resonant frequency reduce. Moreover, the amplitude of FRF of vertical and rotational movements is reduced by raising the rectangular and tapered parts lengths, but increased by raising the rectangular part breadth and cantilever thickness. The resonant frequency goes down by increasing the rectangular and tapered parts lengths and rectangular part breadth, but increases by rising the cantilever thickness. In this paper, we have tried to model the realistic dynamic behavior of V-shaped AFM beam in contact and tapping modes with the most accuracy. Results show good agreement. Based on the experimental results, the present theoretical model can forestall better the realistic behavior of tapping mode than the contact mode for V-shaped AFM cantilever. Based on the complexity of the V-shaped AFM cantilever, this study has been done for the first time in both of the contact and tapping modes.
引用
收藏
页码:9045 / 9060
页数:16
相关论文
共 39 条
  • [21] Analysis of the dynamic behavior of a V-shaped electrothermal microactuator
    Chen, Hao
    Wang, Xin-jie
    Wang, Jiong
    Xi, Zhan-wen
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2020, 30 (08)
  • [22] Sensitivity of V-shaped atomic force microscope cantilevers based on a modified couple stress theory
    Lee, Haw-Long
    Chang, Win-Jin
    MICROELECTRONIC ENGINEERING, 2011, 88 (11) : 3214 - 3218
  • [23] Dynamic analysis of tapping mode atomic force microscope (AFM) for critical dimension measurement
    Xiang, Wuweikai
    Tian, Yanling
    Liu, Xianping
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 64 (64): : 269 - 279
  • [24] A new insight into the vibrational modeling of contact mode for atomic force microscope beams in various immersion ambiances
    Gholizadeh Pasha, Ali Hossein
    Sadeghi, Ali
    MICROSCOPY RESEARCH AND TECHNIQUE, 2021, 84 (04) : 771 - 781
  • [25] Comments on the Dynamic Analysis of V-Shaped Atomic Force Microscopy in Liquid Environment by Considering Timoshenko Beam Theory (vol 39, pg 7251, 2014)
    Damircheli, M.
    Korayem, M. H.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2014, 39 (11) : 8431 - 8431
  • [26] Modelling oscillatory flexure modes of an atomic force microscope cantilever in contact mode whilst imaging at high speed
    Payton, O. D.
    Picco, L.
    Miles, M. J.
    Homer, M. E.
    Champneys, A. R.
    NANOTECHNOLOGY, 2012, 23 (26)
  • [27] Adaptive Control of the Nonlinear Dynamic behavior of the cantilever-sample system of an Atomic Force Microscope
    Fuhrhop, Carlos
    Mercorelli, Paolo
    Quevedo, Daniel E.
    2016 IEEE INTERNATIONAL CONFERENCE ON AUTOMATICA (ICA-ACCA), 2016,
  • [28] Experimental and theoretical studies of frequency response function of dagger-shaped atomic force microscope cantilever in different immersion environments
    Gholizadeh Pasha, A. H.
    Sadeghi, A.
    JOURNAL OF MICROSCOPY, 2020, 279 (01) : 52 - 68
  • [29] The stochastic dynamics of rectangular and V-shaped atomic force microscope cantilevers in a viscous fluid and near a solid boundary
    Clark, M.T.
    Paul, M.R.
    Journal of Applied Physics, 2008, 103 (09):
  • [30] The stochastic dynamics of rectangular and V-shaped atomic force microscope cantilevers in a viscous fluid and near a solid boundary
    Clark, M. T.
    Paul, M. R.
    JOURNAL OF APPLIED PHYSICS, 2008, 103 (09)