Anatomy and intracompartmental pressure measurement technique of the pronator quadratus compartment

被引:7
|
作者
Gerber, A
Masquelet, AC
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Orthoped Surg, Boston, MA 02114 USA
[2] Univ Paris 13, Dept Orthoped Surg & Traumatol, Hop Avicenne, Bobigny, France
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2001年 / 26A卷 / 06期
关键词
compartment syndrome; pronator quadratus; pressure measurement;
D O I
10.1053/jhsu.2001.26656
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The compartment of the pronator quadratus muscle in 25 cadaver specimens is described. Defined by the radius, ulna, and distal interosseous membrane dorsally and the pronator quadratus fascia on the palmar side, the osteofibrous walls of the compartment confine the pronator quadratus muscle within a noncompliant space. A safe and reliable location for compartment pressure measurement was defined at a site 4 cm proximal to the scaphoid tubercule, on the radial side of the flexor carpi radialis tendon and on the ulnar side of the radial artery. These clear anatomic definitions might be useful in diagnosis of compartment syndrome of the pronator quadratus; a clinical investigation may be justified on the basis of pressure measurements made using this technique. Copyright (C) 2001 by the American Society for Surgery of the Hand.
引用
收藏
页码:1129 / 1134
页数:6
相关论文
共 50 条
  • [31] The diagnostic value of intracompartmental pressure measurement, magnetic resonance imaging, and near-infrared spectroscopy in chronic exertional compartment syndrome - A prospective study in 50 patients
    van den Brand, JGH
    Nelson, T
    Verleisdonk, EJMM
    van der Werken, C
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (05): : 699 - 704
  • [32] Measurement of intracompartmental pressure with use of a new electronic transducer-tipped catheter system
    Willy, C
    Gerngross, H
    Sterk, J
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1999, 81A (02): : 158 - 168
  • [33] The Reliability of Measurement of Tissue Pressure in Compartment Syndrome
    Hammerberg, E. Mark
    Whitesides, Thomas E., Jr.
    Seiler, John G., III
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (01) : 24 - 31
  • [34] THE MEASUREMENT OF DYNAMIC COMPARTMENT PRESSURE DURING EXERCISE
    LOGAN, JG
    RORABECK, CH
    CASTLE, GSP
    AMERICAN JOURNAL OF SPORTS MEDICINE, 1983, 11 (04): : 220 - 223
  • [35] The Reliability of Measurement of Tissue Pressure in Compartment Syndrome
    Hammerberg, E. Mark
    Whitesides, Thomas E., Jr.
    Seiler, John G., III
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (09) : E166 - E166
  • [36] MEASUREMENT OF INTRACOMPARTMENTAL PRESSURE - A COMPARISON OF THE SLIT CATHETER, SIDE-PORTED NEEDLE, AND SIMPLE NEEDLE
    MOED, BR
    THORDERSON, PK
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02): : 231 - 235
  • [37] GUARD RING TONOMETER FOR MUSCLE COMPARTMENT PRESSURE MEASUREMENT
    LASKY, LC
    HASELTINE, DL
    CLINICAL RESEARCH, 1976, 24 (04): : A594 - A594
  • [38] Do one-time intracompartmental pressure measurements have a high false-positive rate in diagnosing compartment syndrome?
    Whitney, Augusta
    O'Toole, Robert V.
    Hui, Emily
    Sciadini, Marcus F.
    Pollak, Andrew N.
    Manson, Theodore T.
    Eglseder, W. Andrew
    Andersen, Romney C.
    LeBrun, Christopher
    Doro, Christopher
    Nascone, Jason W.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 76 (02): : 479 - 483
  • [39] Criteria for the diagnosis of chronic compartment syndrome -: Clinical investigation of intracompartmental pressure in tibial anterior muscle during muscular activity on the treadmill
    Sterk, J
    Völker, HU
    Gerngross, H
    Willy, C
    LANGENBECKS ARCHIVES OF SURGERY, 1999, : 665 - 670
  • [40] Compartment syndrome: effect of limb position on pressure measurement
    Kumar, P
    Salil, B
    Bhaskara, KG
    Agrawal, A
    BURNS, 2003, 29 (06) : 626 - 626