A High-Accuracy Programmable Pulse Generator With a 10-ps Timing Resolution

被引:14
|
作者
Liu, Jen-Chieh [1 ]
Huang, Chao-Jen [2 ]
Lee, Pei-Ying [2 ]
机构
[1] Natl United Univ, Dept Elect Engn, Miaoli 36003, Taiwan
[2] Ind Technol Res Inst, Informat & Commun Res Labs, Hsinchu 31040, Taiwan
关键词
Arbitrary waveform; multiphase output; pulse generator (PG); short latency;
D O I
10.1109/TVLSI.2017.2781421
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Automatic test equipment must have high-precision and low-power pulse generators (PGs) for testing memory and device-under-test ICs. This paper describes a high-accuracy and wide-data-rate-range PG with a 10-ps time resolution. The PG comprises an edge combiner (EC) and a multiphase clock generator (MPCG). The EC can produce an arbitrary waveform through 32 phase outputs of the MPCG. The EC adopts a one/zero detector and phase selection logic to define an operational data rate range and a timing resolution, respectively. Therefore, the EC uses the phase selection logic to combine the period window of the one/zero detector with the MPCG output phases. The EC also uses a countdown counter for a wide operational range. In the MPCG, a multiphase oscillator (MPO) adopts a ring oscillator scheme with subfeedback loops to extend its maximum operational frequency. The MPO also uses a phase error corrector to reduce the output phase error resulting from process and layout mismatches. Thus, the PG can obtain high-accuracy waveforms owing to small phase errors. The test chip was implemented using a 0.13-mu m CMOS process. The core area and power consumption of the PG were measured to be 250 x 300 mu m(2) and 18.7 mW, respectively. The data rate range of the PG was determined to be from 3.2 kHz to 893 MHz. The time resolution and average accuracy of the PG were measured to be 10 ps and +/- 0.3 LSB, respectively.
引用
收藏
页码:621 / 629
页数:9
相关论文
共 50 条
  • [41] High-accuracy measurement of pulse amplitudes for new applications of ultrasonic sensors
    Puettmer, A.
    Nowottnick, J.
    Hauptmann, P.
    Sensors and Actuators, A: Physical, 1998, 68 (1 -3 pt 2): : 454 - 459
  • [42] High-accuracy measurement of pulse amplitudes for new applications of ultrasonic sensors
    Puttmer, A
    Nowottnick, J
    Hauptmann, P
    SENSORS AND ACTUATORS A-PHYSICAL, 1998, 68 (1-3) : 454 - 459
  • [43] Terahertz Frequency Comb for High-accuracy, High-resolution Terahertz Spectroscopy
    Yokoyama, Shuko
    Kabetani, Yasuhiro
    Yasui, Takeshi
    Araki, Tsutomu
    2007 CONFERENCE ON LASERS & ELECTRO-OPTICS/QUANTUM ELECTRONICS AND LASER SCIENCE CONFERENCE (CLEO/QELS 2007), VOLS 1-5, 2007, : 213 - 214
  • [44] TIME LAG ELEMENT FOR PULSE COUNTING WITH HIGH-ACCURACY ACTIVITY MEASUREMENT
    RHEIN, KH
    SCHONFELD, E
    ISOTOPENPRAXIS, 1978, 14 (01): : 25 - 28
  • [45] Design and implementation of a ultra-high timing resolution pulse generator based on real-time computation
    Liu, Hanglin
    Chen, Hongliang
    Fu, Zaiming
    Qi, Shirui
    Xiao, Yindong
    Wang, Houjun
    2022 IEEE AUTOTESTCON, 2022,
  • [46] High-resolution and high-accuracy topographic and transcriptional maps of the nucleosome barrier
    Chen, Zhijie
    Gabizon, Ronen
    Brown, Aidan I.
    Lee, Antony
    Song, Aixin
    Diaz-Celis, Cesar
    Kaplan, Craig D.
    Koslover, Elena F.
    Yao, Tingting
    Bustamante, Carlos
    ELIFE, 2019, 8
  • [47] 10-KV HIGH-ACCURACY DC VOLTAGE DIVIDER
    HIRAYAMA, H
    KOBAYASHI, M
    MURAKAMI, K
    KATO, T
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1974, IM23 (04) : 314 - 317
  • [48] A programmable high-resolution ultra-fast delay generator
    Liu, YQ
    Li, HD
    Wang, Y
    Xing, T
    Baghaei, H
    Uribe, J
    Farrell, R
    Wong, WH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1487 - 1490
  • [49] High-accuracy autocollimator calibration by interferometric 2D angle generator
    Heikkinen, V.
    Byman, V.
    Shpak, M.
    Geckeler, R.
    Just, A.
    Krause, M.
    Schumann, M.
    Lassila, A.
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VIII, 2019, 11109
  • [50] High-accuracy experimental analysis and correction of blade tip timing measurement error
    Meng, Yiming
    Xiao, Zhicheng
    Ouyang, Hua
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2024, 39 (07):