Uncertainty of the Sagnac interferometer-based measurement of the modal birefringence of polarization maintaining optical fibers

被引:6
|
作者
Kaczmarek, Cezary [1 ]
机构
[1] Lublin Univ Technol, Inst Elect Syst & Informat Technol, PL-20618 Lublin, Poland
关键词
polarization maintaining fiber; photonic crystal fiber (PCF); modal birefringence; Sagnac interferometer; measurement uncertainty; CORE FIBER; DISPERSION;
D O I
10.5277/oa120419
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Presented is an analysis of the expanded uncertainty of an indirect measurement of modal birefringence of polarization maintaining fibers, based on the Sagnac interferometer and an optical spectrum analyzer. By using this method it is easy to achieve an expanded measurement uncertainty considerably lower than 1%, at a confidence level of 0.95, in measurements of fibers, whose birefringence is independent of the wavelength, as well as fibers, whose birefringence depends on the wavelength, including birefringent photonic crystal fibers (PCF). Guidelines are given, on how to minimize the measurement uncertainty of modal birefringence of these groups of birefringent fibers.
引用
收藏
页码:875 / 885
页数:11
相关论文
共 50 条
  • [41] BIREFRINGENCE MEASUREMENT IN OPTICAL FIBERS BY POLARIZATION OPTICAL TIME-DOMAIN REFLECTOMETRY
    ROSS, JN
    APPLIED OPTICS, 1982, 21 (19): : 3489 - 3495
  • [42] Surface-profile measurement by means of a polarization Sagnac interferometer with parallel optical feedback
    Shirai, T
    Barnes, TH
    Haskel, TG
    OPTICS LETTERS, 1999, 24 (05) : 297 - 299
  • [43] Modal Ellipticity Characterization of Thermally Expanded Core Polarization Maintaining Optical Fibers
    Azami, Nawfel
    Zireg, Mustapha
    Ghalya Bouziane, El
    FREQUENZ, 2011, 65 (11-12) : 303 - 305
  • [44] FABRICATION OF POLARIZATION-MAINTAINING OPTICAL FIBERS WITH STRESS-INDUCED BIREFRINGENCE.
    Sasaki, Yutaka
    Hosaka, Toshihito
    Noda, Juichi
    Reports of the Electrical Communication Laboratory, 1984, 32 (03): : 452 - 460
  • [45] The temperature sensitivity of Sagnac loop interferometer based on polarization maintaining side-hole fiber
    Moon, Dae Seung
    Kim, Bok Hyeon
    Sun, Guoyong
    Han, Young-Geun
    Han, Won-Thek
    Chung, Youngjoo
    2007 PACIFIC RIM CONFERENCE ON LASERS AND ELECTRO-OPTICS, VOLS 1-4, 2007, : 802 - +
  • [46] The temperature sensitivity of Sagnac loop interferometer based on polarization maintaining side-hole fiber
    Moon, Dae Seung
    Kim, Bok Hyeon
    Lin, Aoxiang
    Sun, Guoyong
    Han, Young-Geun
    Han, Won-Taek
    Chung, Youngjoo
    OPTICS EXPRESS, 2007, 15 (13) : 7962 - 7967
  • [47] Sagnac loop interferometer based on polarization maintaining photonic crystal fiber with reduced temperature sensitivity
    Kim, DH
    Kang, JU
    OPTICS EXPRESS, 2004, 12 (19): : 4490 - 4495
  • [48] Non-invasive Vital Signs Monitoring Based on Polarization Maintaining Fiber and Sagnac Interferometer
    Qu, Jiaqi
    Shen, Ying
    Xu, Wei
    Tan, Fengze
    Yu, Changyuan
    Yu, Cheungchuen
    2019 24TH OPTOELECTRONICS AND COMMUNICATIONS CONFERENCE (OECC) AND 2019 INTERNATIONAL CONFERENCE ON PHOTONICS IN SWITCHING AND COMPUTING (PSC), 2019,
  • [49] A fiber strain and vibration sensor based on high birefringence polarization maintaining fibers
    Kang, Juan
    Dong, Xinyong
    Zhu, Yinghao
    Jin, Shangzhong
    Zhuang, Songlin
    OPTICS COMMUNICATIONS, 2014, 322 : 105 - 108
  • [50] Sagnac interferometer-based transmission grating super-resolution digital microholography
    Wanbin Zhang
    Chunlin Shi
    Baosheng Li
    Journal of Optics, 2022, 51 : 203 - 210