Blood flow characteristics in the ascending aorta after aortic valve replacement-a pilot study using 4D-flow MRI

被引:72
|
作者
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ]
Trauzeddel, Ralf F. [1 ,2 ]
Barker, Alex J. [3 ]
Gruettner, Henriette [1 ,2 ]
Markl, Michael [3 ,4 ]
Schulz-Menger, Jeanette [1 ,2 ]
机构
[1] Joint Cooperat Charite Med Fac & Max Delbrueck Ct, Expt & Clin Res Ctr, Working Grp Cardiovasc Magnet Resonance, Berlin, Germany
[2] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[3] Northwestern Univ, Feinberg Sch Med, Dept Radiol, Chicago, IL 60611 USA
[4] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
关键词
Aorta; Hemodynamics; Magnetic resonance imaging; Surgery; Valves; 4D-flow; WALL SHEAR-STRESS; PATTERNS; DILATATION; GUIDELINES;
D O I
10.1016/j.ijcard.2013.11.034
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aortic remodeling after aortic valve replacement (AVR) might be influenced by the postoperative blood flow pattern in the ascending aorta. This pilot study used flow-sensitive four-dimensional magnetic resonance imaging (4D-flow) to describe ascending aortic flow characteristics after various types of AVR. Methods: 4D-flow was acquired in 38 AVR patients (n = 9 mechanical, n = 8 stentless bioprosthesis, n = 14 stented bioprosthesis, n = 7 autograft) and 9 healthy controls. Analysis included grading of vortex and helix flow (0-3 point scale), assessment of systolic flow eccentricity (1-3 point scale), and quantification of the segmental distribution of peak systolic wall shear stress (WSSpeak) in the ascending aorta. Results: Compared to controls, mechanical prostheses showed the most distinct vorticity (2.7 +/- 0.5 vs. 0.7 +/- 0.7; p < 0.001), while stented bioprostheses exhibited most distinct helicity (2.6 +/- 0.7 vs. 1.6 +/- 0.5; p = 0.002). Instead of a physiologic central flow, all stented, stentless and mechanical prostheses showed eccentric flow jets mainly directed towards the right-anterior aortic wall. Stented and stentless prostheses showed an asymmetric distribution of WSSpeak along the aortic circumference, with significantly increased local WSSpeak where the flow jet impinged on the aortic wall. Local WSSpeak was higher in stented (1.4 +/- 0.7 N/m(2)) and stentless (1.3 +/- 0.7 N/m(2)) compared to autografts (0.6 +/- 0.2 N/m(2); p = 0.005 and p = 0.008) and controls (0.7 +/- 0.1 N/m(2); p = 0.017 and p = 0.027). Autografts exhibited lower absolute WSSpeak than controls (0.4 +/- 0.1 N/m(2) vs. 0.7 +/- 0.2 N/m(2); p = 0.003). Conclusions: Flow characteristics in the ascending aorta after AVR are different from native aortic valves and differ between various types of AVR. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [41] 4D-flow MRI derived wall shear stress for the risk stratification of bicuspid aortic valve aortopathy: A systematic review
    Qin, Jiaxing Jason
    Obeidy, Peyman
    Gok, Mustafa
    Gholipour, Alireza
    Grieve, Stuart M. M.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 9
  • [42] Seismocardiography and 4D flow MRI reveal impact of aortic valve replacement on chest acceleration and aortic hemodynamics
    Johnson, Ethan M. I.
    Etemadi, Mozziyar
    Malaisrie, S. Chris
    McCarthy, Patrick M.
    Markl, Michael
    Barker, Alex J.
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (01) : 232 - 235
  • [43] Computational study of aortic hemodynamics for patients with an abnormal aortic valve: The importance of secondary flow at the ascending aorta inlet
    Pirola, S.
    Jarral, O. A.
    O'Regan, D. P.
    Asimakopoulos, G.
    Anderson, J. R.
    Pepper, J. R.
    Athanasiou, T.
    Xu, X. Y.
    APL BIOENGINEERING, 2018, 2 (02):
  • [44] Quantifying right atrial filling and emptying: A 4D-flow MRI study
    Callaghan, Fraser M.
    Arnott, Clare
    Figtree, Gemma A.
    Kutty, Shelby
    Celermajer, David S.
    Grieve, Stuart M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 1046 - 1054
  • [45] 4D-flow MRI of double aortic arch in a 14-year-old patient
    Al-Wakeel, Nadya
    Kelle, Sebastian
    Yigitbasi, Mustafa
    Berger, Felix
    Kuehne, Titus
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2014, 4 (01) : 44 - 46
  • [46] Does the AVNeo valve reduce wall stress on the aortic wall? A cardiac magnetic resonance analysis with 4D-flow for the evaluation of aortic valve replacement with the Ozaki technique
    Pirola, Sergio
    Pirola, Selene
    Mastroiacovo, Giorgio
    Bonomi, Alice
    Manchester, Emily L.
    Fisichella, Serena M.
    Maragna, Riccardo
    Baggiano, Andrea
    Mushtaq, Saima
    Muscogiuri, Giuseppe
    Guglielmo, Marco
    Yun Xu, Xiao
    Pontone, Gianluca
    Polvani, Gianluca
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2023, 64 (06)
  • [47] P57 In Patients with Chronic Descending Aorta Dissection the Maximum Systolic Flow Deceleration Rate in the False Lumen is Associated with Aortic Dilatation: a 4D-flow MRI Study
    Andrea Guala
    Aroa Ruiz-Muñoz
    Lydia Duz-Santoy
    Gisela Teixido-Tura
    Chiara Granato
    Augusto Sao-Aviles
    Lucia La Mura
    Angela Lopez-Sainz
    Maria Luz Servato
    Arturo Evangelista
    Ignacio Ferreira
    Jose Rodriguez-Palomares
    Artery Research, 2019, 25 (Suppl 1) : S98 - S98
  • [48] 4D-flow cardiac magnetic resonance imaging after aortic root replacement with long-valved decellularized aortic homografts: comparison to valve-sparing aortic root replacement and healthy controls
    Cvitkovic, Tomislav
    Bobylev, Dmitry
    Horke, Alexander
    Avsar, Murat
    Beerbaum, Philipp
    Martens, Andreas
    Boethig, Dietmar
    Petena, Elena
    Gutberlet, Marcel
    Beyer, Frerk Hinnerk
    Wacker, Frank
    Cebotari, Serghei
    Haverich, Axel
    Vogel-Claussen, Jens
    Sarikouch, Samir
    Czerner, Christoph
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2022, 61 (06) : 1307 - 1315
  • [49] Left Ventricular Blood Flow Dynamics in Aortic Stenosis before and after Aortic Valve Replacement
    Minagawa, Tadanori
    Saijo, Yoshifumi
    Oktamuliani, Sri
    Kurokawa, Takafumi
    Nakajima, Hiroyuki
    Hasegawa, Kaoru
    Matsuoka, Takayuki
    Shimizu, Takuya
    Miura, Makoto
    Ohara, Takahiro
    Kawamoto, Shunsuke
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 3177 - 3180
  • [50] Measurement of cardiac valve and aortic blood flow velocities in stroke patients: a comparison of 4D flow MRI and echocardiography
    Wehrum, Thomas
    Guenther, Felix
    Fuchs, Alexander
    Schuchardt, Florian
    Hennemuth, Anja
    Harloff, Andreas
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2018, 34 (06): : 939 - 946