Quantitative SSR Analysis of Series-Compensated DFIG-Based Wind Farms Using Aggregated RLC Circuit Model

被引:278
|
作者
Liu, Huakun [1 ]
Xie, Xiaorong [1 ]
Zhang, Chuanyu [1 ]
Li, Yu [2 ]
Liu, Hui [2 ]
Hu, Yinghong [2 ]
机构
[1] Tsinghua Univ, State Key Lab Power Syst, Dept Elect Engn, Beijing 100084, Peoples R China
[2] North China Elect Power Res Inst, Beijing 100045, Peoples R China
基金
中国国家自然科学基金;
关键词
Doubly-fed induction generator; fixed series compensation; impedance model; subsynchronous control interaction; subsynchronous resonance; second-order RLC circuit; SYSTEMS; GENERATOR;
D O I
10.1109/TPWRS.2016.2558840
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new type of subsynchronous resonance (SSR), namely, subsynchronous control interaction (SSCI), was recently observed in doubly-fed induction generators (DFIGs) interfaced with series-compensated power networks. In this paper, a more accurate method based on aggregated RLC circuit model is proposed to intuitively explain and quantitatively evaluate this type of SSR. For a practical power system containing multiple DFIGs and fixed series compensation, an improved impedance model (IM) is derived, which incorporates DFIG's full-scale control system. Around the series-resonant frequency, IM can be further represented with an aggregated RLC circuit model. Its equivalent parameters are worked out and then used for the quantitative assessment of potential SSR risk. The proposed method is applied for SSR analysis of a practical wind farm system in North China that experienced actual SSR incidents. The consistence between the obtained results and field measured data verifies its effectiveness very well. Further, its advantage in accuracy over existing impedance-based approaches is validated by both eigenvalue analysis and time-domain simulations. The method is also used to quantitatively investigate the impact on SSR stability from the various factors, including wind speed, number of online DFIGs and their control parameters.
引用
收藏
页码:474 / 483
页数:10
相关论文
共 50 条
  • [31] Characteristic analysis and mitigation strategy for SSCI in series-compensated DFIG-based wind farm controlled by a virtual synchronous generator
    Liu, Zhijian
    Luo, Jun
    Han, Jiangbei
    Yu, Chengjun
    Fang, Qian
    Li, Pengcheng
    Liu, Chengxi
    ISA TRANSACTIONS, 2024, 150 : 92 - 106
  • [32] Modal Analysis of a DFIG-Based Wind Farm Interfaced With a Series Compensated Network
    Fan, Lingling
    Zhu, Chanxia
    Miao, Zhixin
    Hu, Minqiang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) : 1010 - 1020
  • [33] Robust sub-synchronous damping controller to mitigate SSCI in series-compensated DFIG-based wind park
    Li, Penghan
    Wang, Jie
    Xiong, Linyun
    Ma, Meiling
    Wang, Ziqiang
    Huang, Sunhua
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (09) : 1762 - 1769
  • [34] SSR Damping Controller Design and Optimal Placement in Rotor-Side and Grid-Side Converters of Series-Compensated DFIG-Based Wind Farm
    Mohammadpour, Hossein Ali
    Santi, Enrico
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2015, 6 (02) : 388 - 399
  • [35] Subsynchronous Resonance Mitigation for Series-Compensated DFIG-Based Wind Farm by Using Two-Degree-of-Freedom Control Strategy
    Huang, Po-Hsu
    El Moursi, Mohamed Shawky
    Xiao, Weidong
    Kirtley, James L., Jr.
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (03) : 1442 - 1454
  • [36] A Mechanism Study of SSR for Multiple DFIG Wind Generators Connected to a Series-Compensated Power System
    Xie, Xiaorong
    Wang, Liang
    Liu, Hui
    Liu, Huakun
    Li, Yu
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [37] Mitigating SSR Using DFIG-Based Wind Generation
    Fan, Lingling
    Miao, Zhixin
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2012, 3 (03) : 349 - 358
  • [38] Damping Subsynchronous Resonance in Series-Compensated Wind Farms by Adding Notch Filters to DFIG Controllers
    Liu, Huakun
    Xie, Xiaorong
    Li, Yu
    Liu, Hui
    Hu, Yinghong
    2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015,
  • [39] A Dynamic Equivalent Model for DFIG-Based Wind Farms
    Liu, Mingyang
    Pan, Wenxia
    Zhang, Yibo
    Zhao, Kun
    Zhang, Shida
    Liu, Tongchui
    IEEE ACCESS, 2019, 7 : 74931 - 74940
  • [40] Design of a robust and practicable SSI damping controller using H∞ technique for series compensated DFIG-based wind farms
    Ghafouri, Mohsen
    Karaagac, Ulas
    Mahseredjian, Jean
    Kocar, Ilhan
    Lei, Meng
    ENERGY REPORTS, 2023, 9 : 647 - 655