Comparative study of conductometric glucose biosensor based on gold and on magnetic nanoparticles

被引:28
|
作者
Nouira, Wided [1 ,2 ]
Maaref, Abderrazak
Elaissari, Hamid [3 ]
Vocanson, Francis [4 ]
Siadat, Maryam [5 ]
Jaffrezic-Renault, Nicole [1 ]
机构
[1] Univ Lyon 1, Inst Sci Analyt, F-69622 Villeurbanne, France
[2] Univ Monastir, Lab Interfaces & Mat Avances, Fac Sci Monastir, Monastir 5019, Tunisia
[3] Univ Lyon 1, Lab LAGEP CPE 308G, F-69622 Villeurbanne, France
[4] Univ St Etienne, Lab Hubert Curien, Univ Lyon, F-42023 St Etienne, France
[5] Univ Metz, LASC, ISEA, F-57070 Metz, France
关键词
Magnetic nanoparticles; Gold nanoparticles; Conductometric biosensor; Polyelectrolyte; Glucose oxidase; CARBON NANOTUBES; DNA HYBRIDIZATION; AU ELECTRODE; ENZYME; OXIDASE; IMMOBILIZATION; SURFACE; SENSOR; UREA; NANOTECHNOLOGY;
D O I
10.1016/j.msec.2012.08.043
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
The aim of this study was to show the feasibility and the performances of nanoparticle biosensing. A glucose conductometric biosensor was developed using two types of nanoparticles (gold and magnetic), glucose oxidase (GOD) being adsorbed on PAH (poly(allylamine hydrochloride)) modified nanoparticles, deposited on a planar interdigitated electrode (IDES). The best sensitivities for glucose detection were obtained with magnetic nanoparticles (70 mu M/mM and 3 mu M of detection limit) compared to 45 mu M/mM and 9 mu M with gold nanoparticles and 30 mu M/mM and 50 mu M with GOD directly cross-linked on IDEs. When stored in phosphate buffer (20 mM, pH 7.3) at 4 degrees C, the biosensor showed good stability for more than 12 days. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:298 / 303
页数:6
相关论文
共 50 条
  • [1] Glucose biosensor based on nanohybrid material of gold nanoparticles and glucose oxidase on a bioplatform
    Zhang, Yan
    Jia, Wenjuan
    Cui, Miao
    Dong, Chuan
    Shuang, Shaomin
    Leung, Yuen Kwan
    Choi, Martin M. F.
    BIOTECHNOLOGY JOURNAL, 2011, 6 (05) : 492 - 500
  • [2] A glucose biosensor based on electrodeposited biocomposites of gold nanoparticles and glucose oxidase enzyme
    Bharathi, S
    Nogami, M
    ANALYST, 2001, 126 (11) : 1919 - 1922
  • [3] Gold nanoparticles and polypyrrole for glucose biosensor design
    German, N.
    Voronovic, J.
    Ramanavicius, A.
    Ramanaviciene, A.
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 482 - 485
  • [4] Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
    Xishan Guo
    Bo Liang
    Jinming Jian
    Yelei Zhang
    Xuesong Ye
    Microchimica Acta, 2014, 181 : 519 - 525
  • [5] Electrochemical glucose biosensor based on ZnO nanorods modified with gold nanoparticles
    Xiao Fen Hoo
    Khairunisak Abdul Razak
    Nur Syafinaz Ridhuan
    Noorhashimah Mohamad Nor
    Nor Dyana Zakaria
    Journal of Materials Science: Materials in Electronics, 2019, 30 : 7460 - 7470
  • [6] Glucose biosensor based on a platinum electrode modified with rhodium nanoparticles and with glucose oxidase immobilized on gold nanoparticles
    Guo, Xishan
    Liang, Bo
    Jian, Jinming
    Zhang, Yelei
    Ye, Xuesong
    MICROCHIMICA ACTA, 2014, 181 (5-6) : 519 - 525
  • [7] Electrochemical glucose biosensor based on ZnO nanorods modified with gold nanoparticles
    Hoo, Xiao Fen
    Razak, Khairunisak Abdul
    Ridhuan, Nur Syafinaz
    Nor, Noorhashimah Mohamad
    Zakaria, Nor Dyana
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (08) : 7460 - 7470
  • [8] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    Natalija German
    Almira Ramanaviciene
    Jaroslav Voronovic
    Arunas Ramanavicius
    Microchimica Acta, 2010, 168 : 221 - 229
  • [9] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    German, Natalija
    Ramanaviciene, Almira
    Voronovic, Jaroslav
    Ramanavicius, Arunas
    MICROCHIMICA ACTA, 2010, 168 (3-4) : 221 - 229
  • [10] An electrochemical sulfite biosensor based on gold coated magnetic nanoparticles modified gold electrode
    Rawal, Rachna
    Chawla, Sheetal
    Pundir, Chandra Shekhar
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 144 - 150