Black-blood MR angiography with GRASE: Measurement of flow-induced signal attenuation

被引:3
|
作者
Yu, BC [1 ]
Jara, H [1 ]
Melhem, ER [1 ]
Caruthers, SD [1 ]
Yucel, EK [1 ]
机构
[1] Boston Univ, Sch Med, Boston Med Ctr, Boston, MA 02118 USA
关键词
MR angiography; black-blood angiography; GRASE; turbo spin-echo; phase-encoding profile order;
D O I
10.1002/jmri.1880080623
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated the feasibility of performing black-blood MR angiography (MRA) with the gradient and spin-echo (GRASE) pulse sequence. Phantom experiments and human testing were conducted, and the results were compared with those of turbo spin-echo (TSE). We demonstrated that both techniques are able to produce signal suppression of flowing fluid to background level. With fewer radiofrequency (RF)-refocusing pulses, GRASE pulse sequences could serve as an alternative black-blood technique of reduced RF power exposure and shorter scan time. These relative advantages of GRASE may become useful when high-resolution images are taken.
引用
收藏
页码:1334 / 1337
页数:4
相关论文
共 50 条
  • [31] EXTRACRANIAL CAROTID ARTERIES - EVALUATION WITH BLACK BLOOD MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    WALLNER, B
    BAJAKIAN, R
    KLEEFIELD, J
    KENT, C
    SKILLMAN, JJ
    MENDEL, JB
    ATKINSON, DJ
    RADIOLOGY, 1990, 177 (01) : 45 - 50
  • [32] Mechanisms of blood flow-induced vascular enlargement
    Lehoux, S
    Tronc, F
    Tedgui, A
    BIORHEOLOGY, 2002, 39 (3-4) : 319 - 324
  • [33] FLOW-INDUCED TRAUMA TO BLOOD-CELLS
    SUTERA, SP
    CIRCULATION RESEARCH, 1977, 41 (01) : 2 - 8
  • [34] Postoperative evaluation of superficial temporal artery-middle cerebral artery bypass using an MR angiography technique with combined white-blood and black-blood sequences
    Tsuchiya, Kazuhiro
    Imai, Masamichi
    Nitatori, Toshiaki
    Kimura, Tokunori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (03) : 671 - 676
  • [35] Closed contour edge detection of blood vessel lumen and outer wall boundaries in black-blood MR images
    Yuan, C
    Lin, E
    Millard, J
    Hwang, JN
    MAGNETIC RESONANCE IMAGING, 1999, 17 (02) : 257 - 266
  • [36] Measurements of blood vessel wall areas in black-blood MR images using global minimum snake algorithm
    Lin, E
    Hwang, JN
    Yuan, C
    ICASSP '99: 1999 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, PROCEEDINGS VOLS I-VI, 1999, : 3409 - 3412
  • [37] MR Black-Blood Thrombus Imaging (BTI) for the Early Detection and Quantification of Cerebral Venous Thrombosis
    Yang Qi
    Fan Zhaoyang
    Duan Jiangang
    Ji Xunming
    Li Kuncheng
    Li Debiao
    STROKE, 2016, 47
  • [38] Measurements of blood vessel wall areas in black-blood MR images using global minimum snake algorithm
    Lin, Eugene
    Hwang, Jenq-Neng
    Yuan, Chun
    ICASSP, IEEE International Conference on Acoustics, Speech and Signal Processing - Proceedings, 1999, 6 : 3409 - 3412
  • [39] Real-time, bright-blood, and black-blood magnetic resonance angiography detect in-stent thrombosis
    Hyon, MS
    Kaneda, H
    Ikeno, F
    Nayak, K
    Meyer, CH
    Yeung, AC
    McConnell, MV
    CIRCULATION, 2003, 108 (17) : 453 - 453
  • [40] QUANTITATIVE FLOW MEASUREMENT IN PHASE-CONTRAST MR ANGIOGRAPHY
    WALKER, MF
    SOUZA, SP
    DUMOULIN, CL
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) : 304 - 313