Black-blood MR angiography with GRASE: Measurement of flow-induced signal attenuation

被引:3
|
作者
Yu, BC [1 ]
Jara, H [1 ]
Melhem, ER [1 ]
Caruthers, SD [1 ]
Yucel, EK [1 ]
机构
[1] Boston Univ, Sch Med, Boston Med Ctr, Boston, MA 02118 USA
关键词
MR angiography; black-blood angiography; GRASE; turbo spin-echo; phase-encoding profile order;
D O I
10.1002/jmri.1880080623
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated the feasibility of performing black-blood MR angiography (MRA) with the gradient and spin-echo (GRASE) pulse sequence. Phantom experiments and human testing were conducted, and the results were compared with those of turbo spin-echo (TSE). We demonstrated that both techniques are able to produce signal suppression of flowing fluid to background level. With fewer radiofrequency (RF)-refocusing pulses, GRASE pulse sequences could serve as an alternative black-blood technique of reduced RF power exposure and shorter scan time. These relative advantages of GRASE may become useful when high-resolution images are taken.
引用
收藏
页码:1334 / 1337
页数:4
相关论文
共 50 条
  • [1] Voxel sensitivity function description of flow-induced signal loss in MR imaging: Implications for black-blood MR angiography with turbo spin-echo sequences
    Jara, H
    Yu, BC
    Caruthers, SD
    Melhem, ER
    Yucel, EK
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (03) : 575 - 590
  • [2] MECHANISMS OF FLOW-INDUCED SIGNAL LOSS IN MR ANGIOGRAPHY
    URCHUK, SN
    PLEWES, DB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (04): : 453 - 462
  • [3] Phase Enhancement for Time-of-Flight and Flow-Sensitive Black-Blood MR Angiography
    Kimura, Tokunori
    Ikedo, Masato
    Takemoto, Shuhei
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (02) : 437 - 447
  • [4] Free-breathing black-blood coronary MR angiography: Initial results
    Stuber, M
    Botnar, RM
    Kissinger, KV
    Manning, WJ
    RADIOLOGY, 2001, 219 (01) : 278 - 283
  • [5] BLACK-BLOOD MR-ANGIOGRAPHY WITH 3D TURBO SE
    JARA, H
    KOUWENHOVEN, M
    POON, EK
    BHATIA, R
    WEHRLI, FW
    YUCEL, EK
    RADIOLOGY, 1995, 197 : 187 - 188
  • [6] Black-blood breath-hold MR angiography of thoracic aortic dissection
    Atkinson, DJ
    Douglas, MR
    Bradley, WG
    Ramirez, GF
    Slocum, GR
    Vu, BT
    RADIOLOGY, 1996, 201 : 1493 - 1493
  • [7] FACTORS INFLUENCING FLOW-INDUCED SIGNAL LOSS IN MR-ANGIOGRAPHY - AN IN-VITRO STUDY
    FURST, G
    HOFER, M
    SITZER, M
    KAHN, T
    MULLER, E
    MODDER, U
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1995, 19 (05) : 692 - 699
  • [8] Visualization of the Lenticulostriate Artery With Flow-Sensitive Black-Blood Acquisition in Comparison With Time-of-Flight MR Angiography
    Gotoh, Kimio
    Okada, Tomohisa
    Miki, Yukio
    Ikedo, Masato
    Ninomiya, Ayako
    Kamae, Toshikazu
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (01) : 65 - 69
  • [9] Cerebral Venous Thrombosis: MR Black-Blood Thrombus Imaging with Enhanced Blood Signal Suppression
    Wang, G.
    Yang, X.
    Duan, J.
    Zhang, N.
    Maya, M. M.
    Xie, Y.
    Bi, X.
    Ji, X.
    Li, D.
    Yang, Q.
    Fan, Z.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (10) : 1725 - 1730
  • [10] Velocity-dependent-phase-modulation, the physical mechanism responsible for blood signal attenuation in black-blood MRA with Turbo-SE, GRASE, and conventional-SE: Experiments and theory
    Jara, H
    Yu, BC
    Melhem, ER
    Kouwenhoven, M
    Yucel, EK
    RADIOLOGY, 1997, 205 : 1238 - 1238