On the lack of correlation between PD readings and failure location in High-Voltage Stator Bars

被引:0
|
作者
da Silva, M. J. [1 ]
Pereira, F. [1 ]
Lamas, T. E. [1 ]
Cordeiro, J. F. [1 ]
Goncalves, C. S. [1 ]
Aoki, T. K. [1 ]
Faria, E. [1 ]
Hildinger, T. [1 ]
机构
[1] Voith Hydro Ltda, Sao Paulo, Brazil
关键词
partial discharges; Roebel bar; Multi-turn coil; hydrogenerator;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
After showing in a previous work that PD measurements suffer from poor repeatability and reproducibility, the present study turns now to a more qualitative approach, investigating if a method of PD fault location along a Roebel bar length can be used to identify insulation critical areas that later on could fail under electrical stress. Typical insulation "damages" have been created on the components in advance by submitting them to both thermal mechanical and electrical aging tests. Once such preliminary aging was done, the critical areas along the bars length were identified by mapping the PD readings on each component. Afterwards, every bar was subjected to a destructive electrical breakdown test. At last, the breakdown locations were compared with the PD mappings to search for any possible correlation between the two events. Based upon the present results, such correlation does not exist.
引用
收藏
页码:181 / 184
页数:4
相关论文
共 50 条
  • [31] The Influence of Stator-Rotor Slot Combination on Performance of High-Voltage Asynchronous Motor
    Qiu, Hongbo
    Zhang, Yong
    Yang, Cunxiang
    Yi, Ran
    JOURNAL OF CONTROL AUTOMATION AND ELECTRICAL SYSTEMS, 2019, 30 (06) : 1126 - 1134
  • [32] Radiometric location of partial discharge sources on energized high-voltage plant
    Moore, PJ
    Portugues, IE
    Glover, IA
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2264 - 2272
  • [33] Diagnosis and Location of High-voltage Cable Fault Based on Sheath Current
    He, Wen
    Li, Hao
    Tu, Jingyun
    Yang, Ting
    Meng, Jia
    Li, Hua
    Lin, Fuchang
    2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3353 - 3359
  • [34] INTELLIGENT FAULT DETECTION AND LOCATION IN ELECTRICAL HIGH-VOLTAGE TRANSMISSION LINES
    Guerraiche, Khaled
    Abbou, Amine Bouadjmi
    Dekhici, Latifa
    REVUE ROUMAINE DES SCIENCES TECHNIQUES-SERIE ELECTROTECHNIQUE ET ENERGETIQUE, 2024, 69 (03): : 269 - 276
  • [35] Equivalent Circuit Simulation of Stator Coil End of High-Voltage Electrical Machine at High dV/dt
    Kato, Tetsuji
    Maki, Kohji
    2017 IEEE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE (IEMDC), 2017,
  • [36] Overshoot Level Studies of PD Exposure in High-Voltage Motor Isolation
    Hammarstrom, Thomas
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2025, 32 (02) : 1172 - 1180
  • [37] A dynamic model for the failure replacement of aging high-voltage transformers
    Enders J.
    Powell W.B.
    Egan D.
    Energy Systems, 2010, 1 (1) : 31 - 59
  • [38] High-voltage pulse bushing with induced voltage distribution between sections
    Poloskov, Artem
    Serebrennikov, Maksim
    Egorov, Ivan
    VACUUM, 2021, 194
  • [39] Failure investigation of buffer layers in high-voltage XLPE cables
    Chen, Yun
    Hui, Baojun
    Cheng, Yanting
    Hao, Yanpeng
    Fu, Mingli
    Yang, Lin
    Hou, Shuai
    Li, Licheng
    ENGINEERING FAILURE ANALYSIS, 2020, 113
  • [40] Propagation of fast PD signals within stator bars, performance and limitations of a high frequency monitoring system
    Lesaint, O
    Lebey, T
    Dinculescu, S
    Debruyne, H
    Petit, A
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 1112 - 1115