Based on the BEM of Internal Electric Field Simulation of Shunt Dry Reactor

被引:0
|
作者
Mei Xin [1 ,2 ]
Lu Tiecheng [1 ]
Su Ziming [1 ]
Guo Ting [1 ]
Yue Long [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan, Peoples R China
[2] Hubei Elect Power Co, Wuhan Power Supply Co, Wuhan, Peoples R China
关键词
Reactive power compensation; BEM; parallel capacitor; electromagnetic field numerical calculation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This article uses the BEM electromagnetic field calculation way to simulate the internal electric field distribution of shunt reactor, and discusses the internal electric field impact of reactor about shunt reactor sealed surface insulation cracking and the installation position of multi-tap arc-suppression coil. Simulation results show that sealed surface crack is not only easy to cause the sealed surface flashover but also will cause bad effect about the turn-to-turn insulation. The article also discusses installation position of multi-tap arc-suppression coil for which can provide feasible suggestion for the production and selection of shunt reactor.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Understanding the Pathophysiology of Portosystemic Shunt by Simulation Using an Electric Circuit
    Kim, Moonhwan
    Lee, Keon-Young
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [42] Overvoltage Simulation Analysis and Suppression of Breaking in a 35 kV Shunt Reactor
    Chen, Jing
    Chen, Xiaoyue
    Feng, Siying
    Liu, Xinmeng
    Liu, Qin
    ENERGIES, 2025, 18 (05)
  • [43] Hydrodynamic behaviors and mixing characteristics in an internal loop airlift reactor based on CFD simulation
    Wadaugsorn, Kiattichai
    Limtrakul, Sunun
    Vatanatham, Terdthai
    Ramachandran, Palghat A.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 113 : 125 - 139
  • [44] Simulation of internal electric field of particle source water absorbed dose absolute measurement device
    Hang Z.
    Liu Y.
    Song M.
    Wei K.
    Wang H.
    Liu C.
    Teng Z.
    Geng X.
    He Jishu/Nuclear Techniques, 2024, 47 (01):
  • [45] MATHEMATICAL SIMULATION OF DIFFUSION OF 2 CHARGED IMPURITIES IN A SEMICONDUCTOR ALLOWING FOR AN INTERNAL ELECTRIC-FIELD
    GALANIN, MP
    MALKOVICH, RS
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1986, 20 (08): : 911 - 914
  • [46] Simulation and analysis of temperature field of high voltage reactor based on multi physical field coupling
    Wu S.
    Ma H.
    Jiang N.
    Tian T.
    Chen X.
    Tan F.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2019, 47 (04): : 17 - 24
  • [47] Natural hp-BEM for the electric field integral equation with singular solutions
    Bespalov, Alexei
    Heuer, Norbert
    NUMERICAL METHODS FOR PARTIAL DIFFERENTIAL EQUATIONS, 2012, 28 (05) : 1466 - 1480
  • [48] ELECTRIC FIELD SIMULATION OF IONIZATION CHAMBER USED IN TRITIUM MEASUREMENT IN TAIL GAS OF MOLTEN SALT REACTOR
    Qian, Nan
    Wang, Guanghua
    Yu, Huang
    Zeng, Youshi
    Bao, Guangliang
    Wu, Shengwei
    Liu, Wei
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 7, 2018,
  • [49] Internal electric field modification method based on region segmentation for vacuum interrupters
    Li, Hongyang
    Wang, Zhongyu
    Jiang, Wensong
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (05) : 1195 - 1201
  • [50] Amending redesign of torque converter based on internal flow field simulation
    Hydraulic Mechanical Transmission Institute, Jilin University, Changchun 130025, China
    不详
    Jixie Gongcheng Xuebao, 2006, 2 (125-128):