Test-retest reliability of grip strength measurement in full elbow extension to evaluate maximum grip strength

被引:27
|
作者
Savva, C. [1 ]
Karagiannis, C. [1 ]
Rushton, A. [2 ]
机构
[1] European Univ, Dept Hlth Sci, Nicosia, Cyprus
[2] Univ Birmingham, Sch Hlth & Populat Sci, Coll Med & Dent Sci, Birmingham, W Midlands, England
关键词
Test-retest reliability; grip strength measurement; hand strength; Jamar dynamometer; LATERAL EPICONDYLALGIA;
D O I
10.1177/1753193412449804
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this study was to investigate the test-retest reliability of measurement of grip strength in full elbow extension. The grip strengths of 19 healthy participants were measured using the Jamar dynamometer by the same rater on two occasions with an interval of 7 days between measures. Test-retest reliability of grip strength measurement was excellent in full elbow extension and associated with low values of standard error of measurement and small variations in the differences between the two measurements in both testing sessions.
引用
收藏
页码:183 / 186
页数:4
相关论文
共 50 条
  • [21] Test-retest intra-rater reliability of grip force in patients with stroke
    Hammer, A
    Lindmark, B
    [J]. JOURNAL OF REHABILITATION MEDICINE, 2003, 35 (04) : 189 - 194
  • [22] Assessment of grip force sense test-retest reliability in healthy male participants
    Li, Yan-Xia
    Li, Lin
    Chen, Xing
    Zhao, Yang
    Zhao, Xi
    Zhang, Chong-Long
    [J]. ERGONOMICS, 2022, 65 (12) : 1621 - 1630
  • [23] The short-term reliability of grip strength measurement and the effects of posture and grip span
    Watanabe, T
    Owashi, K
    Kanauchi, Y
    Mura, N
    Takahara, M
    Ogino, T
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03): : 603 - 609
  • [24] Test-retest reliability of isometric and isokinetic wrist strength
    Prando, Beatriz Cardinal
    Carvalho, Cristiano
    Petrella, Marina
    Serrao, Paula Regina Mendes da Silva
    [J]. JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (01) : 138 - 142
  • [25] The test-retest reliability of an inclined squat strength test protocol
    Munich, H
    Cipriani, D
    Hall, C
    Nelson, D
    Falkel, J
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1997, 26 (04): : 209 - 213
  • [26] Test-retest reliability of a handheld dynamometer for measurement of isometric cervical muscle strength
    Vannebo, Katrine Tranaas
    Iversen, Vegard Moe
    Fimland, Marius Steiro
    Mork, Paul Jarle
    [J]. JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2018, 31 (03) : 557 - 565
  • [27] MEASUREMENT OF GRIP STRENGTH - REPLY
    ROBERTSON, JC
    [J]. CLINICAL BIOMECHANICS, 1992, 7 (03) : 188 - 189
  • [28] GRIP STRENGTH IN DIFFERENT POSITIONS OF ELBOW AND SHOULDER
    SU, CY
    LIN, JH
    CHIEN, TH
    CHENG, KF
    SUNG, YT
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1994, 75 (07): : 812 - 815
  • [29] THE RELATIONSHIP BETWEEN ELBOW POSITION AND GRIP STRENGTH
    KUZALA, EA
    VARGO, MC
    [J]. AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1992, 46 (06): : 509 - 512
  • [30] Functional strength measurement in cerebral palsy: feasibility, test-retest reliability, and construct validity
    Aertssen, Wendy
    Smulders, Ellen
    Smits-Engelsman, Bouwien
    Rameckers, Eugene
    [J]. DEVELOPMENTAL NEUROREHABILITATION, 2019, 22 (07) : 453 - 461