Evaluation of Hand Tendon Movement by Using High-Frequency Ultrasound Vector Doppler Imaging

被引:15
|
作者
Wang, Min-Yuan [1 ]
Yang, Tai-Hua [1 ,2 ,3 ]
Huang, Hsin [1 ]
Hsu, Hsiu-Yun [4 ]
Kuo, Li-Chieh [5 ]
Su, Fong-Chin [1 ]
Huang, Chih-Chung [1 ,2 ]
机构
[1] Natl Cheng Kung Univ, Dept Biomed Engn, Tainan 709, Taiwan
[2] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Dept Orthoped, Tainan, Taiwan
[4] Natl Cheng Kung Univ Hosp, Dept Phys Med & Rehabil, Tainan, Taiwan
[5] Natl Cheng Kung Univ, Dept Occupat Therapy, Tainan, Taiwan
关键词
Tendons; Ultrasonic imaging; Phantoms; Injuries; Doppler effect; Optical fiber devices; High-frequency ultrasound; hand tendon; tendon rotation; rehabilitation; vector Doppler imaging; IN-VIVO; METACARPAL;
D O I
10.1109/TBME.2020.2974244
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Injuries to the hands, wrists, and fingers often involve damage to the tendons. The ability to measure tendon movements during the rehabilitation process can provide clinicians with important information in the quantification of tendon injuries. Conventionally, the tendon is considered a single spring-like structure during force transmission, and its twisted structure is neglected. Recently, clinicians believed that the twisted fiber structure (which enables tendon rotation during movement) of the tendon can provide it with a degree of elasticity and improve the efficiency of force transmission. However, observation of the hand tendon rotation in vivo by using the current imaging modalities is difficult. Methods: In this study, a 40-MHz high-frequency vector Doppler imaging (HFVDI) was used to visualize the movement of the hand tendon during muscle contraction. The performance of HFVDI was verified using a rotation phantom experiment. Two human experiments were designed in the present study: 1) participants were allowed to bend their distal and proximal interphalangeal (DIP and PIP) joints of fingers freely and 2) the PIP joint of the finger was fixed such that only the DIP could be moved. The HFVDIs of the flexor digitorum superficialis (FDS) and flexor digitorum profundus (FDP) tendons were obtained in the transverse and longitudinal views to observe the movements of the hand tendon during finger movements. Results: The average longitudinal displacements of the FDS and FDP were approximately 3-4 mm for free bending of the finger; however, it was reduced when only the DIP was moved. The rotational phenomenon of the FDS and FDP tendons was observed in the transverse view, which demonstrated the different rotational behaviors of the FDS and FDP fibers during muscle contraction. Conclusion: All the results validated the potential of HFVDI as a novel tool for visualizing tendon rotation and would be useful in providing quantitative information regarding tendon function to determine the rehabilitation process following injuries.
引用
收藏
页码:2945 / 2952
页数:8
相关论文
共 50 条
  • [21] Evaluation of Pericardial Thickening and Adhesion Using High-Frequency Ultrasound
    Lin, Jiadong
    Li, Ming
    Huang, Yanling
    Yuan, Yuchan
    Chen, Yuhan
    Lu, Zhijuan
    Lin, Fuchun
    Yang, Xiaoxia
    Xi, Dan
    Chen, Yingqiao
    Chen, Jie
    Wang, Yuepeng
    Wei, Yuan
    Huang, Xinsheng
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2023, 36 (08) : 841 - 848
  • [22] High-frequency ultrasound imaging of the intervertebral disc
    Johnson, S
    Mcnally, D
    Halliwell, M
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (07): : 939 - 947
  • [23] High-frequency ultrasound tissue harmonic imaging
    Silverman, RH
    Lizzi, FL
    Coleman, DJ
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U933 - U933
  • [24] Echogenic liposomes in high-frequency ultrasound imaging
    Lu, Sheng-Chieh
    Ho, Ja-An
    Yeh, Chih-Kuang
    [J]. 2007 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1-6, 2007, : 2203 - +
  • [25] Cardiac Fiber Imaging Using High-Frequency Ultrasound in Animal Models
    Fei, B.
    Qin, X.
    Wang, S.
    Shen, M.
    Wagner, M.
    Zhang, X.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 482 - +
  • [26] Reduction of stent artifacts using high-frequency harmonic ultrasound imaging
    Frijlink, ME
    Goertz, DE
    Van Der Steen, AFW
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (10): : 1335 - 1342
  • [27] Intraoperative imaging of lymphatic vessel using ultra high-frequency ultrasound
    Hayashi, Akitatsu
    Visconti, Giuseppe
    Yamamoto, Takumi
    Giacalone, Guido
    Hayashi, Nobuko
    Handa, Mayumi
    Yoshimatsu, Hidehiko
    Salgarello, Marzia
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (05): : 778 - 780
  • [28] High-frequency ultrasound transducer by using inversion layer technique for intravascular ultrasound imaging
    Sung, J. H.
    Jeong, J. S.
    [J]. ELECTRONICS LETTERS, 2016, 52 (12) : 1003 - 1004
  • [29] High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos
    Ketterling, Jeffrey A.
    Aristizabal, Orlando
    Yiu, Billy Y. S.
    Turnbull, Daniel H.
    Phoon, Colin K. L.
    Yu, Alfred C. H.
    Silverman, Ronald H.
    [J]. SCIENTIFIC REPORTS, 2017, 7
  • [30] Value of high-frequency Doppler ultrasound for prostate cancer detection
    Klauser, A
    Feuchtner, G
    Frauscher, F
    Bartsch, G
    Halpern, EJ
    [J]. JOURNAL OF UROLOGY, 2003, 169 (04): : 463 - 463