Calibration of a two-color soft x-ray diagnostic for electron temperature measurement

被引:3
|
作者
Reusch, L. M. [1 ]
Den Hartog, D. J. [1 ]
Franz, P. [2 ]
Goetz, J. [1 ]
McGarry, M. B. [1 ]
Stephens, H. D. [1 ,3 ]
机构
[1] Univ Wisconsin, Madison, WI 53703 USA
[2] Consorzio RFX, Padua, Italy
[3] Pierce Coll Ft Steilacoom, Lakewood, WA 98498 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2016年 / 87卷 / 11期
关键词
RADIATION;
D O I
10.1063/1.4961281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXRDF) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXRDF measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXRDF discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXRDF analysis rather than instrumentation effects. Published by AIP Publishing.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] High-performance double-filter soft x-ray diagnostic for measurement of electron temperature structure and dynamics
    McGarry, M. B.
    Franz, P.
    Den Hartog, D. J.
    Goetz, J. A.
    Thomas, M. A.
    Reyfman, M.
    Kumar, S. T. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [22] Observation of Seeded Mn Kβ Stimulated X-Ray Emission Using Two-Color X-Ray Free-Electron Laser Pulses
    Kroll, Thomas
    Weninger, Clemens
    Fuller, Franklin D.
    Guetg, Marc W.
    Benediktovitch, Andrei
    Zhang, Yu
    Marinelli, Agostino
    Alonso-Mori, Roberto
    Aquila, Andy
    Liang, Mengning
    Koglin, Jason E.
    Koralek, Jake
    Sokaras, Dimosthenis
    Zhu, Diling
    Kern, Jan
    Yano, Junko
    Yachandra, Vittal K.
    Rohringer, Nina
    Lutman, Alberto
    Bergmann, Uwe
    PHYSICAL REVIEW LETTERS, 2020, 125 (03)
  • [23] Soft X-ray calibration for the NeXT X-ray telescope
    Maeda, Yoshitonto
    Hayashi, Takayuki
    Mori, Hideyuki
    Nakamura, Ryoko
    Satoh, Takuro
    Sekiguchi, Akiko
    Someya, Kentaro
    Tamura, Kensuke
    Ishida, Manabu
    Osawa, Takeyuki
    Shirata, Takayuki
    Suzuki, Masaki
    Ogasaka, Yasushi
    Furuzawa, Akhiro
    Haba, Yoshito
    Miyazawa, Takuya
    Kunieda, Hideyo
    Yamashita, Koujun
    Okajima, Takashi
    SPACE TELESCOPES AND INSTRUMENTATION 2008: ULTRAVIOLET TO GAMMA RAY, PTS 1 AND 2, 2008, 7011
  • [24] Design and initial operation of a two-color soft x-ray camera system on the Compact Toroidal Hybrid experiment
    Herfindal, J. L.
    Dawson, J. D.
    Ennis, D. A.
    Hartwell, G. J.
    Loch, S. D.
    Maurer, D. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [25] Two-Color Soft X-Ray Lasing in a High-Density Nickel-like Krypton Plasma
    Tissandier, F.
    Gautier, J.
    Goddet, J-P
    Kabacinski, A.
    Sebban, S.
    Nejdl, J.
    Kozlova, M.
    Maynard, G.
    PHYSICAL REVIEW LETTERS, 2020, 124 (13)
  • [26] Table-top two-color soft X-ray laser by means of Ni-like plasmas
    Masoudnia, Leili
    Ruiz-Lopez, Mabel
    Bleiner, Davide
    PHYSICS OF PLASMAS, 2016, 23 (04)
  • [27] Time-Resolved Two-Color X-ray Pump / X-ray Probe Photoelectron Spectroscopy at LCLS
    Al Haddad, Andre
    Picon, Antonio
    Bucher, Maximilian
    Doumy, Gilles
    Coffee, Ryan
    Holmes, Michael
    Krzywinski, Jacek
    Lutman, Alberto
    Marinelli, Agostino
    Moeller, Stefan
    Osipov, Timur
    Pratt, Stephen
    Ratner, Dan
    Ray, Dipanwita
    Walter, Peter
    Young, Linda
    Southworth, Stephen
    Bostedt, Christoph
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS EUROPE & EUROPEAN QUANTUM ELECTRONICS CONFERENCE (CLEO/EUROPE-EQEC), 2017,
  • [28] 2D electron temperature diagnostic using soft x-ray imaging technique
    Nishimura, K.
    Sanpei, A.
    Tanaka, H.
    Ishii, G.
    Kodera, R.
    Ueba, R.
    Himura, H.
    Masamune, S.
    Ohdachi, S.
    Mizuguchi, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (03):
  • [29] A multichord soft x-ray diagnostic for electron temperature profile measurements in RFX-mod
    Bonomo, F.
    Franz, P.
    Murari, A.
    Gadani, G.
    Alfier, A.
    Pasqualotto, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [30] Experimental demonstration of two-color x-ray free-electron-laser pulses via wakefield excitation
    Bettoni, S.
    Craievich, P.
    Dax, A.
    Ganter, R.
    Guetg, M. W.
    Huppert, M.
    Marcellini, F.
    Pestana, R. Neto
    Reiche, S.
    Prat, E.
    Trisorio, A.
    Vicario, C.
    Lutman, A. A.
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2021, 24 (08)