Behavior of Unrestrained and Restrained Bare Steel Columns Subjected to Localized Fire

被引:41
|
作者
Zhang, Chao [1 ]
Gross, John L. [1 ]
McAllister, Therese P. [1 ]
Li, Guo-Qiang [2 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
关键词
Steel columns; Localized fires; Local and global buckling; Temperature gradient; Axial and rotational restraints; Sequentially coupled thermal-mechanical simulation; Analysis and Computation; THERMAL RESPONSE; RESISTANCE; DESIGN; SIMULATION; MEMBERS; BEAMS; MODEL;
D O I
10.1061/(ASCE)ST.1943-541X.0001225
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Real fires start from localized burning and will not develop to flashover in an open space or in large open-plan compartments. Temperatures of gas and exposed steel columns in localized fires are not uniform. Current structural fire design methods are based on uniform heating and, therefore, do not account for temperature gradients in real fires. This paper presents a numerical investigation of the behavior of bare steel columns subjected to a localized fire. The buckling behaviors of steel columns surrounded by and adjacent to a localized fire are investigated. Simple approaches are provided to calculate the temperatures of steel columns surrounded by and adjacent to a localized fire. Sequentially coupled thermal-mechanical simulations were conducted. Unrestrained, axially restrained, and rotationally restrained steel columns of various load ratios and dimensions subjected to different heating conditions were considered. The study found that the behavior of steel columns subjected to a localized fire may be completely different from that of columns subjected to a standard International Organization for Standardization (ISO) 834 fire. The steel columns surrounded by a localized fire fail by local buckling, while the same columns subjected to a standard ISO 834 fire fail by global buckling. The temperatures at which steel columns buckled (buckling temperature) when surrounded by a localized fire are higher than those of columns subjected to both a standard ISO 834 fire and an assumed uniform steel temperature condition. However, the buckling temperature of steel columns adjacent to a localized fire may be much lower than that of the columns subjected to both a standard ISO 834 fire and an assumed uniform steel temperature condition. The location of the localized fire relative to the column has a significant effect on the temperature and buckling behavior of steel columns. Structural fire design for steel columns based on a standard ISO 834 fire or a uniform steel temperature may be conservative if the potential real fires are localized fires surrounding the columns and may not be conservative if the potential real fires are localized fires adjacent to the columns. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Post-buckling behaviours of axially restrained steel columns in fire
    Li, Guo-Qiang
    Wang, Peijun
    Hou, Hetao
    STEEL AND COMPOSITE STRUCTURES, 2009, 9 (02): : 89 - 101
  • [32] EXPERIMENTAL RESEARCH AND NUMERICAL ANALYSIS OF RESTRAINED COLUMNS OF STEEL FRAMES IN FIRE
    Wang, Xin-Tang
    Zhou, Ming
    Ji, Yao
    Wang, Wan-Zhen
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 2263 - 2267
  • [33] Fire resistance of steel columns with elastically restrained axial elongation and bending
    Valente, JC
    Neves, IC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1999, 52 (03) : 319 - 331
  • [34] The performance in fire of restrained steel columns in multi-storey construction
    Shepherd, PG
    Burgess, IW
    Plank, RJ
    O'Connor, DJ
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 333 - 340
  • [35] Structural fire performance of axially and rotationally restrained stainless steel columns
    Pournaghshband, A.
    Afshan, S.
    Foster, A. S. J.
    THIN-WALLED STRUCTURES, 2019, 137 (561-572) : 561 - 572
  • [36] Coupled Structural-thermal Calculations for Restrained Steel Columns in Fire
    Kwasniewski, Laslaw
    Ali, Faris
    Balcerzak, Marcin
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2013, 4 (01) : 59 - 70
  • [37] Damage evaluation of a restrained steel column subjected to indoor blast and fire
    Ding Y.
    Chen Y.
    Shi Y.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2017, 36 (05): : 79 - 86
  • [38] Behavior of unrestrained hot-rolled steel I-beams exposed to localized fire: An experimental study
    Suman, Saurabh
    Samanta, Avik
    ENGINEERING STRUCTURES, 2023, 296
  • [39] Practical analysis method for restrained steel columns in fire (II) -restrained columns under combined axial force and bending moment
    Li, Guoqiang
    Wang, Peijun
    Wang, Yong-Chang
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (04): : 23 - 29
  • [40] Experimental behavior of steel beam-columns subjected to fire-induced thermal gradients
    Dwaikat, M. M. S.
    Kodur, V. K. R.
    Quiel, S. E.
    Garlock, M. E. M.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (01) : 30 - 38