Behavior of Unrestrained and Restrained Bare Steel Columns Subjected to Localized Fire

被引:41
|
作者
Zhang, Chao [1 ]
Gross, John L. [1 ]
McAllister, Therese P. [1 ]
Li, Guo-Qiang [2 ]
机构
[1] NIST, Gaithersburg, MD 20899 USA
[2] Tongji Univ, State Key Lab Disaster Reduct Civil Engn, Shanghai 200092, Peoples R China
关键词
Steel columns; Localized fires; Local and global buckling; Temperature gradient; Axial and rotational restraints; Sequentially coupled thermal-mechanical simulation; Analysis and Computation; THERMAL RESPONSE; RESISTANCE; DESIGN; SIMULATION; MEMBERS; BEAMS; MODEL;
D O I
10.1061/(ASCE)ST.1943-541X.0001225
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Real fires start from localized burning and will not develop to flashover in an open space or in large open-plan compartments. Temperatures of gas and exposed steel columns in localized fires are not uniform. Current structural fire design methods are based on uniform heating and, therefore, do not account for temperature gradients in real fires. This paper presents a numerical investigation of the behavior of bare steel columns subjected to a localized fire. The buckling behaviors of steel columns surrounded by and adjacent to a localized fire are investigated. Simple approaches are provided to calculate the temperatures of steel columns surrounded by and adjacent to a localized fire. Sequentially coupled thermal-mechanical simulations were conducted. Unrestrained, axially restrained, and rotationally restrained steel columns of various load ratios and dimensions subjected to different heating conditions were considered. The study found that the behavior of steel columns subjected to a localized fire may be completely different from that of columns subjected to a standard International Organization for Standardization (ISO) 834 fire. The steel columns surrounded by a localized fire fail by local buckling, while the same columns subjected to a standard ISO 834 fire fail by global buckling. The temperatures at which steel columns buckled (buckling temperature) when surrounded by a localized fire are higher than those of columns subjected to both a standard ISO 834 fire and an assumed uniform steel temperature condition. However, the buckling temperature of steel columns adjacent to a localized fire may be much lower than that of the columns subjected to both a standard ISO 834 fire and an assumed uniform steel temperature condition. The location of the localized fire relative to the column has a significant effect on the temperature and buckling behavior of steel columns. Structural fire design for steel columns based on a standard ISO 834 fire or a uniform steel temperature may be conservative if the potential real fires are localized fires surrounding the columns and may not be conservative if the potential real fires are localized fires adjacent to the columns. (C) 2014 American Society of Civil Engineers.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Behavior of axially loaded steel short columns subjected to a localized fire
    Zhang, Chao
    Choe, Lisa
    Seif, Mina
    Zhang, Zhe
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2015, 111 : 103 - 111
  • [2] FEA on mechanical behavior of axially restrained concrete-filled steel tubular columns subjected to fire
    Liu, Faqi
    Pan, Yanchong
    Yang, Hua
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 : 310 - 317
  • [3] On the buckling of axially restrained steel columns in fire
    Shepherd, P. G.
    Burgess, I. W.
    ENGINEERING STRUCTURES, 2011, 33 (10) : 2832 - 2838
  • [4] Shear Breaking of Columns Subjected to Localized Fire
    Burnier, Olivier
    STRUCTURES IN FIRE, 2016, : 885 - 892
  • [5] Fire Resistances of Restrained Steel Beams Subjected to Fire Loads
    Zhen Guo
    Rui Gao
    Xuecheng Zhang
    Xingzhi Jia
    KSCE Journal of Civil Engineering, 2018, 22 : 3028 - 3038
  • [6] Performance of Axially Restrained Hollow and Concrete Filled Oval Steel Columns Subjected to Hydrocarbon Fire
    Ali, F.
    Jeffers, A.
    Goodfellow, N.
    Nadjai, A.
    Scullion, T.
    Gardner, J.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2012, 3 (02) : 181 - 197
  • [7] Fire Resistances of Restrained Steel Beams Subjected to Fire Loads
    Guo, Zhen
    Gao, Rui
    Zhang, Xuecheng
    Jia, Xingzhi
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (08) : 3028 - 3038
  • [8] Calculation of forces generated in restrained concrete columns subjected to fire
    Ali, F.
    Nadjai, A.
    Silcock, G.
    Talamona, D.
    Abu-Tair, Abid
    Journal of Applied Fire Science, 2003, 12 (02): : 125 - 135
  • [9] Simulating the fire-thermal-structural behavior in a localized fire test on a bare steel beam
    Zhang, Chao
    Yu, Hong-Xia
    Choe, Lisa
    Gross, John
    Li, Guo-Hua
    ENGINEERING STRUCTURES, 2018, 163 : 61 - 70
  • [10] Buckling of restrained steel columns due to fire conditions
    Hozjan, Tomaz
    Planinc, Igor
    Saje, Miran
    Srpcic, Stanislav
    STEEL AND COMPOSITE STRUCTURES, 2008, 8 (02): : 159 - 178