DO WE NEED DEFIBRILLATION THRESHOLD TESTING? - A PILOT STUDY

被引:2
|
作者
Kovacevic-Kostic, Natasa [1 ,4 ]
Karan, Radmila [1 ,4 ]
Obrenovic-Kircanski, Biljana [2 ,3 ]
Velinovic, M. [2 ,4 ]
Vranes, M. [2 ,4 ]
Mitrovic, P. [2 ,3 ]
Milasinovic, G. [2 ,5 ]
机构
[1] Clin Ctr Serbia, Ctr Anesthesiol, Belgrade 11000, Serbia
[2] Univ Belgrade, Fac Med, Belgrade 11000, Serbia
[3] Clin Ctr Serbia, Clin Cardiol, Belgrade 11000, Serbia
[4] Clin Ctr Serbia, Clin Cardiac Surg, Belgrade 11000, Serbia
[5] Clin Ctr Serbia, Pacemaker Ctr, Belgrade 11000, Serbia
关键词
Implantable cardioverter defibrillator; defibrillation threshold testing; sudden cardiac death; primary prevention; heart failure; treatment; IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR; GUIDELINES; PATTERNS; EPISODES; THERAPY; UPDATE;
D O I
10.2298/ABS1302465K
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Defibrillation threshold testing (DFT) is a standard procedure during implantable cardioverter defibrillator (ICD) implantation, however, it is not without risks. We compared the one-year follow-up period in ICD-implanted patients, with and without DFT performed during implantation, for preventive indication in regard to appropriate and inappropriate ICD detection and therapy. One group consisted of 20 patients without DFT; another was comprised of 20 patients where DFT had been performed. There was no difference in the development of ventricular tachyarrhythmias between the groups. Appropriate therapy of ICD was 100%. DFT is not a predictor for successful ICD detection and therapy of ventricular tachyarrhythmias.
引用
收藏
页码:465 / 474
页数:10
相关论文
共 50 条
  • [21] Anaesthetic drugs and defibrillation threshold testing - Reply
    Dopp, Anna Legreid
    Miller, John M.
    Tisdale, James E.
    DRUGS, 2008, 68 (13) : 1922 - 1923
  • [22] Myocardial stunning following defibrillation threshold testing
    Mollerus, Michael
    Naslund, Leslee
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2007, 19 (03) : 213 - 216
  • [23] NEUROMONITORING TO IMPROVE THE SAFETY OF DEFIBRILLATION THRESHOLD TESTING
    EDMONDS, HL
    RODRIGUEZ, RA
    SINGER, I
    ITTICHAIKULTHOL, W
    YLIHANKALA, A
    STROKE, 1994, 25 (03) : 734 - 734
  • [24] Defibrillation Threshold Testing in Patients with Hypertrophic Cardiomyopathy
    Roberts, Brett D.
    Hood, Robert E.
    Saba, Magdi M.
    Dickfeld, Timm M.
    Saliaris, Anastasios P.
    Shorofsky, Stephen R.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (11): : 1342 - 1346
  • [25] Myocardial stunning following defibrillation threshold testing
    Michael Mollerus
    Leslee Naslund
    Journal of Interventional Cardiac Electrophysiology, 2007, 19 : 213 - 216
  • [26] Routine Coagulation Testing: Do We Need a Discard Tube?
    Masih, Markas
    Kakkar, Naveen
    INDIAN JOURNAL OF HEMATOLOGY AND BLOOD TRANSFUSION, 2014, 30 (04) : 347 - 350
  • [27] Do We Need Early ACPA Testing in Inflammatory Arthritis?
    Deane, Kevin D.
    JOURNAL OF RHEUMATOLOGY, 2016, 43 (01) : 1 - 2
  • [28] Routine Coagulation Testing: Do We Need a Discard Tube?
    Markas Masih
    Naveen Kakkar
    Indian Journal of Hematology and Blood Transfusion, 2014, 30 : 347 - 350
  • [29] Genetic testing for vulnerable populations: What kinds of communication we need and do not need
    Schillinger, Dean
    Dohan, Daniel
    AMERICAN JOURNAL OF BIOETHICS, 2008, 8 (06): : 12 - 14
  • [30] Unfitness to Plead, Insanity and the Law Commission: Do We Need a Diagnostic Threshold?
    Mason, James
    JOURNAL OF CRIMINAL LAW, 2021, 85 (04): : 268 - 279