Energy-subtraction Compton scatter camera design considerations: A Monte Carlo study of timing and energy resolution effects

被引:11
|
作者
Valentine, JD [1 ]
Bonnerave, C [1 ]
Rohe, RC [1 ]
机构
[1] UNIV CINCINNATI,DEPT NUCL MED,CINCINNATI,OH 45221
关键词
D O I
10.1109/23.596977
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An energy-subtraction Compton scatter camera (ESCSC) was previously proposed for medical imaging applications. This ESCSC consists of a primary detector system (silicon) and a secondary detector system (cadmium-zinc-telluride) for preferred detection of Compton scatter and photoelectric absorption interactions, respectively. To further evaluate the usefulness of this ESCSC for medical imaging, the following characteristics have been simulated: the random emission of gamma rays in time; detector timing, energy and spatial resolution; list mode data acquisition; and post-acquisition coincidence analysis. The resulting optimization of detector characteristics, data acquisition and analysis techniques, and administered activity is presented and discussed. One significant result of these simulations is that a localized activity of about 1.0 mCi allows for recovery of the majority of preferred events while eliminating the majority of interfering events when 10 and 50 ns FWHM timing resolutions for silicon and cadmium-zinc-telluride, respectively, are assumed. Consequently, the proposed ESCSC should be capable of acquiring data for administered activities similar to those used with current mechanically-collimated imaging cameras.
引用
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [1] Energy-subtraction Compton scatter camera design considerations: A Monte Carlo study of timing and energy resolution effects
    Valentine, JD
    Bonnerave, C
    Rohe, RC
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1039 - 1043
  • [2] An energy-subtraction Compton scatter camera design for in vivo medical imaging of radiopharmaceuticals
    Rohe, RC
    Valentine, JD
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) : 3256 - 3263
  • [3] False preferred event analysis for the energy-subtraction Compton scatter camera
    Khamzin, M
    Valentine, JD
    Li, JQ
    [J]. 2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 719 - 724
  • [4] False-preferred event analysis for the energy-subtraction Compton scatter camera
    Khamzin, M
    Valentine, JD
    Li, JQ
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (06) : 3262 - 3268
  • [5] Spatially-variant backprojection point kernel function of an energy-subtraction Compton scatter camera for medical imaging
    Rohe, R.C.
    Sharfi, M.M.
    Kecevar, K.A.
    Valentine, J.D.
    Bonnerave, C.
    [J]. IEEE Transactions on Nuclear Science, 1997, 44 (6 pt 2): : 2477 - 2482
  • [6] The spatially-variant backprojection point kernel function of an energy-subtraction Compton scatter camera for medical imaging
    Rohe, RC
    Sharfi, MM
    Kecevar, KA
    Valentine, JD
    Bonnerave, C
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2477 - 2482
  • [7] The spatially-variant back-projection point kernel function of an energy-subtraction Compton scatter camera for medical imaging
    Rohe, RC
    Sharfi, MM
    Kecevar, KA
    Valentine, JD
    Bonnerave, C
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1260 - 1264
  • [8] A MONTE-CARLO STUDY OF MULTIPLE SCATTER EFFECTS IN COMPTON SCATTER DENSITOMETRY
    SPELLER, RD
    HORROCKS, JA
    [J]. MEDICAL PHYSICS, 1988, 15 (05) : 707 - 712
  • [9] Design Considerations Of A Compton Camera For Low Energy Medical Imaging
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cresswell, J. R.
    Grint, A. N.
    Lazarus, I.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Simpson, J.
    [J]. INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES, 2009, 1194 : 90 - +
  • [10] EFFECT OF ENERGY RESOLUTION ON SCATTER FRACTION IN SCINTIGRAPHIC IMAGING - MONTE-CARLO STUDY
    KOJIMA, A
    MATSUMOTO, M
    TAKAHASHI, M
    UEHARA, S
    [J]. MEDICAL PHYSICS, 1993, 20 (04) : 1107 - 1113