Optimal discharge pressure in transcritical CO2 heat pump water heater with internal heat exchanger based on pinch point analysis

被引:42
|
作者
Ye, Zuliang [1 ]
Wang, Yikai [1 ]
Song, Yulong [1 ]
Yin, Xiang [1 ]
Cao, Feng [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Transcritical CO2 heat pump water heater; Internal heat exchanger; Optimal discharge pressure; Pinch point analysis; REJECTION PRESSURE; PERFORMANCE; CYCLE; SYSTEM; OPTIMIZATION;
D O I
10.1016/j.ijrefrig.2020.06.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
In transcritical CO2 heat pump water heater, the pinch point in gas cooler and the utilization of internal heat exchanger (IHX) both have a significant impact on the optimal discharge pressure and system performance. A theoretical model was developed to investigate the effects, and the results demonstrated that when the water inlet temperature was low, the pinch point prevented the gas cooler outlet temperature from approaching the water inlet temperature at low discharge pressure, which impaired the coefficient of performance (COP). The application of IHX could reduce the gas cooler outlet temperature by 4.9 degrees C when the water inlet temperature was 10 degrees C and the discharge pressure was 8.5 MPa. In this condition, combining with the subcooling effect of IHX, the COP was accordingly improved by 26.3%. Regardless of the working condition, using IHX lowered the optimal discharge pressure and enhanced corresponding optimal COP. In addition, parametric analyses were conducted, and the results indicated that the augment of water outlet temperature and ambient temperature resulted in the rise of optimal discharge pressure. The increase of water inlet temperature mostly enlarged the optimal discharge pressure as well. Overall, the optimal discharge pressure varied within a range of 8.53 MPa to 13.38 MPa. The reduction of optimal discharge pressure caused by using IHX intensified with the increase of water inlet and outlet temperature. Nevertheless, the effect of ambient temperature was various depending on the working condition. The reduction of optimal discharge could be up to 1.18 MPa when the effectiveness of IHX was 0.6. (C) 2020 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:12 / 20
页数:9
相关论文
共 50 条
  • [21] Comprehensive evaluation of the transcritical CO2 ejector-expansion heat pump water heater
    Wang, Yikai
    Yin, Yonggao
    Cao, Feng
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 276 - 289
  • [22] Design and simulation of residential CO2 transcritical heat pump water heater in central China
    Zhang, X. P.
    Fan, X. W.
    Wang, F. K.
    Shen, H. G.
    Zheng, H. F.
    Duan, H. L.
    [J]. 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 4, 2008, : 775 - 779
  • [23] Experimental investigation of the extreme seeking control on a transcritical CO2 heat pump water heater
    Cui, Ce
    Zong, Shuo
    Song, Yulong
    Yin, Xiang
    Cao, Feng
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 133 : 111 - 122
  • [25] EXPERIMENTAL AND SIMULATION STUDY ON TRANSCRITICAL CO2 AIR SOURCE HEAT PUMP WATER HEATER
    Yang, Junlan
    Chen, Dandan
    Zhang, Xin
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (12): : 581 - 587
  • [26] Optimal compressor discharge pressure and performance characteristics of transcritical CO2 heat pump for crude oil heating
    Li, Conghui
    Jiang, Peixue
    Zhu, Yinhai
    [J]. International Journal of Refrigeration, 2022, 144 : 99 - 107
  • [27] Determination of the optimal discharge pressure of the transcritical CO2 heat pump cycles for heating and cooling performances based on new correlation
    Saeed Maddah
    Mohammad Reza Safaei
    [J]. Journal of Thermal Analysis and Calorimetry, 2021, 145 : 1537 - 1546
  • [28] Determination of the optimal discharge pressure of the transcritical CO2 heat pump cycles for heating and cooling performances based on new correlation
    Maddah, Saeed
    Safaei, Mohammad Reza
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (03) : 1537 - 1546
  • [29] Experimental Study of Optimum Heat Rejection Pressure for a CO2 Heat Pump Water Heater
    Fan Xiaowei
    Zhang Xianping
    Wang Fengkun
    Ma Qiang
    [J]. ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 4, 2010, : 535 - +
  • [30] Performance Analysis of CO2 Heat Pump Water Heater with an Ejector
    Ju Cheng-cheng
    Yang Jun-lan
    Qu Hong-wei
    [J]. 2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,