Assessment of coronary flow reserve using fast velocity encoded cine MRI: Validation study using positron emission tomography and application for noninvasive detection of restenosis after coronary intervention

被引:0
|
作者
Sakuma, H
Koskenvuo, JW
Kawada, N
Niemi, PN
Knuuti, J
Saito, Y
机构
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
738
引用
收藏
页码:268 / 268
页数:1
相关论文
共 50 条
  • [31] Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers
    Mario Petretta
    Andrea Soricelli
    Giovanni Storto
    Alberto Cuocolo
    Journal of Nuclear Cardiology, 2008, 15 : 456 - 465
  • [32] Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers
    Petretta, Mario
    Soricelli, Andrea
    Storto, Giovanni
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (03) : 456 - 465
  • [33] Can coronary flow reserve using transthoracic color Doppler echo in the left anterior descending artery predict restenosis after PTCA? Usefulness of contrast enhanced diastolic coronary flow velocity
    Okada, M
    Ota, T
    Okura, H
    Nagae, K
    Abe, Y
    Yoh, H
    Yanagi, S
    Hirota, K
    Watanabe, H
    Yoshikawa, J
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 391A - 391A
  • [34] Assessment of Coronary Flow Velocity Reserve in the Left Main Trunk Using Phase-contrast MR Imaging at 3T: Comparison with 15O-labeled Water Positron Emission Tomography
    Kikuchi, Yasuka
    Naya, Masanao
    Oyama-Manabe, Noriko
    Manabe, Osamu
    Sugimori, Hiroyuki
    Kudo, Kohsuke
    Kato, Fumi
    Aikawa, Tadao
    Tsutsui, Hiroyuki
    Tamaki, Nagara
    Shirato, Hiroki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2019, 18 (02) : 134 - 141
  • [35] Noninvasive assessment of the infarct-related coronary artery blood flow velocity using phase-contrast magnetic resonance imaging after coronary angioplasty
    Furber, AP
    Lethimonnier, F
    Le Jeune, JJ
    Balzer, P
    Jallet, P
    Tadéi, A
    Geslin, P
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (01): : 24 - 30
  • [36] Long-term outcome of discordance between fractional flow reserve and coronary flow velocity reserve after deferral of percutaneous coronary intervention using the clinically adopted 0.80 FFR cut-off
    Van De Hoef, T. P.
    Meuwissen, M.
    Damman, P.
    Piek, M.
    Chamuleau, S. A. J.
    Voskuil, M.
    Henriques, J. P.
    De Winter, R. J.
    Tijssen, J. G. P.
    Piek, J. J.
    EUROPEAN HEART JOURNAL, 2013, 34 : 716 - 716
  • [37] Measurement of coronary flow response to cold pressor stress in asymptomatic women with cardiovascular risk factors using spiral velocity-encoded cine MRI at 3 Tesla
    Maroules, Christopher D.
    Chang, Alice Y.
    Kontak, Andrew
    Dimitrov, Ivan
    Kotys, Melanie
    Peshock, Ronald M.
    ACTA RADIOLOGICA, 2010, 51 (04) : 420 - 426
  • [38] Measurement of the blood flow rate and velocity in coronary artery stenosis using intracoronary frequency domain optical coherence tomography: Validation against fractional flow reserve
    Zafar, Haroon
    Sharif, Faisal
    Leahy, Martin J.
    IJC HEART & VASCULATURE, 2014, 5 : 68 - 71
  • [39] Using Gaussian process for velocity reconstruction after coronary stenosis applicable in positron emission particle tracking: An in-silico study
    Keramati, Hamed
    de Vecchi, Adelaide
    Rajani, Ronak
    Niederer, Steven A.
    PLOS ONE, 2023, 18 (12):
  • [40] Incremental prognostic value of downstream positron emission tomography perfusion imaging after coronary computed tomography angiography: a study using machine learning
    Lehtonen, Eero
    Kujala, Iida
    Tamminen, Jonne
    Maaniitty, Teemu
    Saraste, Antti
    Teuho, Jarmo
    Knuuti, Juhani
    Klen, Riku
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (02) : 285 - 292