Study of impact of the AP1000® reactor vessel upper internals design on fuel performance

被引:9
|
作者
Xu, Yiban [2 ]
Conner, Michael [2 ]
Yuan, Kun [2 ]
Dzodzo, Milorad B. [2 ]
Karoutas, Zeses [2 ]
Beltz, Steven A. [2 ]
Ray, Sumit [2 ]
Bissett, Teresa A. [2 ]
Chieng, Ching-Chang [1 ]
Kao, Min-Tsung [1 ]
Wu, Chung-Yun [1 ]
机构
[1] Natl Tsing Hua Univ, Hsinchu 30043, Taiwan
[2] Westinghouse Elect Co, Cranberry Township, PA 16066 USA
关键词
BOUNDARY;
D O I
10.1016/j.nucengdes.2012.06.036
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
One aspect of the AP1000((R) 1) reactor design is the reduction in the number of major components and simplification in manufacturing. One design change relative to current Westinghouse reactors of similar size is the reduction in the number of reactor vessel outlet nozzles/hot legs leaving the upper plenum from three to two. With regard to fuel performance, this design difference creates a different flow field in the AP1000 reactor vessel upper plenum (the region above the core). The flow exiting core and entering the upper plenum must turn 90 degrees, flow laterally through the upper plenum around support structures, and exit through one of the two outlet nozzles. While the flow in the top of the core is mostly axial, there is some lateral flow component as the core flow reacts to the flow field and pressure distribution in the upper plenum. The pressure distribution in the upper plenum varies laterally depending upon various factors including the proximity to the outlet nozzles. To determine how the lateral flow in the top of the AP1000 core compares to current Westinghouse reactors, a computational fluid dynamics (CFD) model of the flow in the upper portion of the AP1000 reactor vessel including the top region of the core, the upper plenum, the reactor vessel outlet nozzles, and a portion of the hot legs was created. Due to geometric symmetry, the computational domain was reduced to a quarter (from the top view) that includes 1/4 of the top of the core, 1/4 of the upper plenum, and 1/2 of an outlet nozzle. Results from this model include predicted velocity fields and pressure distributions throughout the model domain. The flow patterns inside and around guide tubes clearly demonstrate the influence of lateral flow due to the presence of the outlet nozzles. From these results, comparisons of AP1000 flow versus current Westinghouse plants were performed. Field performance information from current Westinghouse plants will be shown to demonstrate an experience base of acceptable core lateral flows. From this experience base and the AP1000 CFD results, acceptability of the AP1000 upper plenum design on the fuel performance of the AP1000 fuel design will be demonstrated. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 134
页数:7
相关论文
共 50 条
  • [41] Physical characteristics preliminary analysis on AP1000 fuel assembly
    Cao, B., 1600, Atomic Energy Press (47):
  • [42] Thermal-stress modeling of AP1000 reactor pressure vessel due to transient pressurized thermal shock
    Ma Z.
    Zhang H.
    He P.
    Xu B.
    Luo Y.
    Zhou J.
    Zhongguo Kexue Jishu Kexue/Scientia Sinica Technologica, 2017, 47 (07): : 685 - 691
  • [43] USE OF PRA IN THE DESIGN OF THE WESTINGHOUSE AP1000 PLANT
    Lutz, Robert J.
    Scobel, James H.
    Anderson, Richard G.
    Schulz, Terry
    ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 3, 2009, : 905 - 909
  • [44] ADVANCED FIRST CORE DESIGN FOR THE WESTINGHOUSE AP1000
    Fetterman, Robert J.
    ICONE17, VOL 5, 2009, : 167 - 174
  • [45] EPR and AP1000 pass UK design assessment
    不详
    NUCLEAR ENGINEERING INTERNATIONAL, 2012, 57 (671): : 6 - 6
  • [46] AP1000 core design with 50% MOX loading
    Fetterman, Robert J.
    ANNALS OF NUCLEAR ENERGY, 2009, 36 (03) : 324 - 330
  • [47] Analysis of likelihood of lower head failure and ex-vessel fuel coolant interaction energetics for AP1000
    Esmaili, H
    Khatib-Rahbar, M
    NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (15) : 1583 - 1605
  • [48] AP1000 nuke design gets critical nod
    不详
    POWER, 2003, 147 (06) : 21 - 21
  • [49] Thermohydraulic evaluation of a MOX (U, Th)O2fuel application in an AP1000 reactor typical fuel assembly
    Da Cunha C.J.C.M.R.
    De Andrade Lima F.R.
    Rodríguez D.G.
    Da Cunha, Caio Július César Miranda Rodrigues (caio.julius@ufpe.br), 1600, Inderscience Publishers (14): : 97 - 113
  • [50] Detailed neutronic calculations of the AP1000 reactor core with the Serpent code
    de Stefani, Giovanni Laranjo
    Losada Moreira, Joao Manoel
    Maiorino, Jose Rubens
    Russo Rossi, Pedro Carlos
    PROGRESS IN NUCLEAR ENERGY, 2019, 116 : 95 - 107