A pilot study evaluating a new low-volume colon cleansing procedure for capsule colonoscopy

被引:52
|
作者
Hartmann, D. [1 ]
Keuchel, M. [2 ]
Philipper, M. [3 ]
Gralnek, I. M. [4 ,5 ]
Jakobs, R. [6 ]
Hagenmueller, F. [7 ]
Neuhaus, H. [3 ]
Riemann, J. F. [6 ,8 ]
机构
[1] Sana Klinikum Lichtenberg, Dept Internal Med 1, D-10365 Berlin, Germany
[2] Bethesda Krankenhaus Bergedorf, Dept Internal Med, Hamburg, Germany
[3] Evangel Krankenhaus, Dept Internal Med, Dusseldorf, Germany
[4] Technion Israel Inst Technol, Rappaport Fac Med, Dept Ambulatory Care Serv, Haifa, Israel
[5] Technion Israel Inst Technol, Rappaport Fac Med, Dept Gastroenterol, Haifa, Israel
[6] Klinikum Stadt Ludwigshafen, Dept Internal Med C, D-6700 Ludwigshafen, Germany
[7] Asklepios Klin Altona, Dept Med 1, Hamburg, Germany
[8] Klinikum Stadt Ludwigshafen, Lebensblicke Fdn Early Detect Colorectal Canc, D-6700 Ludwigshafen, Germany
关键词
COLORECTAL-CANCER; ENDOSCOPY; POLYPS; MULTICENTER;
D O I
10.1055/s-0031-1291611
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: Colon capsule endoscopy (CCE) offers an alternative approach for endoscopic visualization of the colon. Some of the current CCE bowel cleansing regimens use sodium phosphate, which has raised safety concerns. Therefore, the aim of the current study was to test the feasibility and efficacy of a new low-volume, sodium phosphate-free polyethylene glycol (PEG) bowel preparation. Methods: The first 26 patients (original cleansing procedure) received a colon cleansing regimen of PEG plus ascorbic acid: patients drank 1L in the evening and 0.75 L in the morning before capsule ingestion. Patients also drank an additional 0.5 L PEG boost and an optional 0.25 L PEG boost during the capsule procedure. Following an interim analysis, the cleansing procedure of the subsequent 24 patients was modified, with the morning intake before capsule ingestion being increased to 1L, as well as the second boost (0.25 L) being administered 1-2 hours earlier (modified cleansing procedure). Results: The overall colon cleanliness was considered to be good or excellent in 83% (original cleansing procedure) and 82% (modified cleansing procedure) of patients, without any significant difference between regimens (P > 0.05). In 37/49 (76%) of the CCE procedures, the hemorrhoidal plexus was identified and thus the examination was considered complete, with no significant differences between the two CCE cleansing procedures. The capsule sensitivity and specificity for detecting colonic polyps >= 6mm were 91% (95% CI 70%-98%) and 94% (95% CI 87%-97%), respectively, compared with standard optical colonoscopy. Conclusion: A colon cleansing procedure using PEG + ascorbic acid for capsule colonoscopy yielded an adequate cleansing level in >80% of patients, a completion rate of 76%, and good accuracy for detecting polyps. This procedure may be considered as an alternative, particularly for patients in whom sodium phosphate-based preparations are contraindicated.
引用
收藏
页码:482 / 486
页数:5
相关论文
共 50 条
  • [21] A Pharmacokinetics Evaluation of a New, Low-Volume, Oral Sulfate Colon Cleansing Preparation in Patients With Renal or Hepatic Impairment and Healthy Volunteers
    Pelham, Russell W.
    Alcorn, Harry, Jr.
    Cleveland, Mark vB.
    JOURNAL OF CLINICAL PHARMACOLOGY, 2010, 50 (03): : 350 - 354
  • [22] Safety of low-volume PEG-asc bowel cleansing preparation for colonoscopy: identifying patients at risk for hypokalemia in a prospective cohort study
    Reumkens, Ankie
    Bakker, Christine Minke
    van Kraaij, Sebastiaan J. W.
    Winkens, Bjorn
    Raijmakers, Maarten T.
    van Nunen, Annick B.
    van Deursen, Cees Th B. M.
    Masclee, Ad A. M.
    ENDOSCOPY INTERNATIONAL OPEN, 2021, 09 (08) : E1198 - E1204
  • [23] Assessment of bowel cleansing quality in colon capsule endoscopy using machine learning: a pilot study
    Buijs, Maria Magdalena
    Ramezani, Mohammed Hossain
    Herp, Jurgen
    Kroijer, Rasmus
    Kobaek-Larsen, Morten
    Baatrup, Gunnar
    Nadimi, Esmaeil S.
    ENDOSCOPY INTERNATIONAL OPEN, 2018, 6 (08) : E1044 - E1050
  • [24] A low-volume polyethylene glycol plus ascorbate solution for bowel cleansing prior to colonoscopy: The NORMO randomised clinical trial
    Ponchon, Thierry
    Boustiere, Christian
    Heresbach, Denis
    Hagege, Herve
    Tarrerias, Anne-Laure
    Halphen, Marc
    DIGESTIVE AND LIVER DISEASE, 2013, 45 (10) : 820 - 826
  • [25] Randomized trial of low-volume PEG solution versus standard PEG plus electrolytes for bowel cleansing before colonoscopy
    Ell, Christian
    Fischbach, Wolfgang
    Bronisch, Hans-Joachim
    Dertinger, Stefan
    Layer, Peter
    Ruenzi, Michael
    Schneider, Thomas
    Kachel, Guenther
    Grueger, Joerg
    Koellinger, Michael
    Nagell, Waltraud
    Goerg, Karl-Josel
    Wanitschke, Roland
    Gruss, Hans-Juergen
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2008, 103 (04): : 883 - 893
  • [26] Effectiveness of very low-volume preparation for colonoscopy: A prospective, multicenter observational study
    Maida, Marcello
    Sinagra, Emanuele
    Morreale, Gaetano Cristian
    Sferrazza, Sandro
    Scalisi, Giuseppe
    Schillaci, Dario
    Ventimiglia, Marco
    Macaluso, Fabio Salvatore
    Vettori, Giovanni
    Conoscenti, Giuseppe
    Di Bartolo, Concetta
    Garufi, Serena
    Catarella, Domenico
    Manganaro, Michele
    Virgilio, Clara Maria
    Camilleri, Salvatore
    WORLD JOURNAL OF GASTROENTEROLOGY, 2020, 26 (16) : 1950 - 1961
  • [27] Effectiveness of very low-volume preparation for colonoscopy: A prospective, multicenter observational study
    Marcello Maida
    Emanuele Sinagra
    Gaetano Cristian Morreale
    Sandro Sferrazza
    Giuseppe Scalisi
    Dario Schillaci
    Marco Ventimiglia
    Fabio Salvatore Macaluso
    Giovanni Vettori
    Giuseppe Conoscenti
    Concetta Di Bartolo
    Serena Garufi
    Domenico Catarella
    Michele Manganaro
    Clara Maria Virgilio
    Salvatore Camilleri
    World Journal of Gastroenterology, 2020, (16) : 1950 - 1961
  • [28] A Grading System to Evaluate Colon Cleansing for the PillCam® Colon Capsule: A Validation Study
    Leighton, Jonathan A.
    Rex, Douglas K.
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB225 - AB225
  • [29] A grading scale to evaluate colon cleansing for the PillCam COLON capsule: a reliability study
    Leighton, J. A.
    Rex, D. K.
    ENDOSCOPY, 2011, 43 (02) : 123 - 127
  • [30] PillCam colon capsule endoscopy compared with colonoscopy for colorectal tumor diagnosis:: a prospective pilot study
    Schoofs, N.
    Deviere, J.
    Van Gossum, A.
    ENDOSCOPY, 2006, 38 (10) : 971 - 977