Limitations of Airway Dimension Measurement on Images Obtained Using Multi-Detector Row Computed Tomography

被引:26
|
作者
Oguma, Tsuyoshi [1 ]
Hirai, Toyohiro [1 ]
Niimi, Akio [2 ]
Matsumoto, Hisako [1 ]
Muro, Shigeo [1 ]
Shigematsu, Michio [3 ]
Nishimura, Takashi [4 ]
Kubo, Yoshiro [5 ]
Mishima, Michiaki [1 ]
机构
[1] Kyoto Univ, Dept Resp Med, Grad Sch Med, Kyoto, Japan
[2] Nagoya City Univ, Dept Med Oncol & Immunol, Grad Sch Med Sci, Nagoya, Aichi, Japan
[3] Sumitomo Hosp, Dept Resp Med, Osaka, Japan
[4] Kyoto Katsura Hosp, Dept Resp Med, Kyoto, Japan
[5] Kansai Elect Power Hosp, Dept Respirol, Osaka, Japan
来源
PLOS ONE | 2013年 / 8卷 / 10期
关键词
OBSTRUCTIVE PULMONARY-DISEASE; CT; VALIDATION; ACCURACY; ASTHMA; LUMEN; COPD;
D O I
10.1371/journal.pone.0076381
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives: (a) To assess the effects of computed tomography (CT) scanners, scanning conditions, airway size, and phantom composition on airway dimension measurement and (b) to investigate the limitations of accurate quantitative assessment of small airways using CT images. Methods: An airway phantom, which was constructed using various types of material and with various tube sizes, was scanned using four CT scanner types under different conditions to calculate airway dimensions, luminal area (Ai), and the wall area percentage (WA%). To investigate the limitations of accurate airway dimension measurement, we then developed a second airway phantom with a thinner tube wall, and compared the clinical CT images of healthy subjects with the phantom images scanned using the same CT scanner. The study using clinical CT images was approved by the local ethics committee, and written informed consent was obtained from all subjects. Data were statistically analyzed using one-way ANOVA. Results: Errors noted in airway dimension measurement were greater in the tube of small inner radius made of material with a high CT density and on images reconstructed by body algorithm (p<0.001), and there was some variation in error among CT scanners under different fields of view. Airway wall thickness had the maximum effect on the accuracy of measurements with all CT scanners under all scanning conditions, and the magnitude of errors for WA% and Ai varied depending on wall thickness when airways of <1.0-mm wall thickness were measured. Conclusions: The parameters of airway dimensions measured were affected by airway size, reconstruction algorithm, composition of the airway phantom, and CT scanner types. In dimension measurement of small airways with wall thickness of <1.0 mm, the accuracy of measurement according to quantitative CT parameters can decrease as the walls become thinner.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] DOSIMETRY METHODS FOR MULTI-DETECTOR COMPUTED TOMOGRAPHY
    Gancheva, M.
    Dyakov, I.
    Vassileva, J.
    Avramova-Cholakova, S.
    Taseva, D.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 190 - 193
  • [42] MULTI-DETECTOR COMPUTED TOMOGRAPHY IN ABDOMINAL TUBERCULOSIS
    Omprakash, A. R.
    D'Souza, Reshmina C.
    Sudarshan, Sunil H.
    Yadav, Vishwanath
    Aithala, P. S.
    Pai, Ramakrishna J.
    Fernandes, Aaron Marion
    Kaneria, Tessa Jose
    [J]. JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (03): : 565 - 568
  • [43] Assessment of temporal resolution of multi-detector row computed tomography in helical acquisition mode using the impulse method
    Ichikawa, Katsuhiro
    Hara, Takanori
    Urikura, Atsushi
    Takata, Tadanori
    Ohashi, Kazuya
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (04): : 374 - 381
  • [44] Imaging evaluation of the liver using multi-detector row computed tomography in micropigs as potential living liver donors
    Ryu, Jung Min
    Kim, Dong Hyun
    Lee, Min Young
    Lee, Sang Hun
    Park, Jae Hong
    Yun, Seung Pil
    Jang, Min Woo
    Kim, Seong Hwan
    Rho, Gyu Jin
    Han, Ho Jae
    [J]. JOURNAL OF VETERINARY SCIENCE, 2009, 10 (02) : 93 - 98
  • [45] Anthropological Measurement of the Juvenile Clavicle Using Multi-Detector Computed Tomography-Affirming Reliability
    Brough, Alison L.
    Bennett, Jonathan
    Morgan, Bruno
    Black, Sue
    Rutty, Guy N.
    [J]. JOURNAL OF FORENSIC SCIENCES, 2013, 58 (04) : 946 - 951
  • [46] Diagnosis of coronary in-stent restenosis using new generation multi-detector row spiral computed tomography
    Halon
    Gaspar, T.
    Adawi, S.
    Peled, N.
    Schliamser, J. E.
    Rubinshtein, R.
    Lewis, B. S.
    [J]. EUROPEAN HEART JOURNAL, 2005, 26 : 534 - 534
  • [47] Radiological Anatomy of the Right Adrenal Vein: Preliminary Experience with Multi-detector Row Computed Tomography
    Matsuura, T.
    Takase, K.
    Takahashi, S.
    [J]. 13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 2250 - +
  • [48] Imaging features of intraductal papillary mucinous neoplasms of the pancreas in multi-detector row computed tomography
    Tan, Ling
    Zhao, Ya-E
    Wang, Deng-Bin
    Wang, Qing-Bing
    Hu, Jing
    Chen, Ke-Min
    Deng, Xia-Xing
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (32) : 4037 - 4043
  • [49] Effectiveness of multi-detector row computed tomography in detection of the presence and extent of ductal carcinoma in situ
    Izo Kimijima
    Kazuya Yoshida
    Ryo Tamura
    Takuya Moriya
    [J]. Breast Cancer, 2013, 20 : 26 - 33
  • [50] Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean
    Shin, Ho Sik
    Chung, Byung Ha
    Lee, Sang Eun
    Kim, Woo Jin
    Ha, Hong Il
    Yang, Chul Woo
    [J]. YONSEI MEDICAL JOURNAL, 2009, 50 (02) : 262 - 265